Instruction Manual for BEKA models including: BA584G, General Purpose Field Mounting Two Input Rate Totaliser
Abbreviated Instruction manuals
BA534G and BA584G Pulse input Externally powered rate totalisers
File Info : application/pdf, 2 Pages, 790.09KB
DocumentDocument1. DESCRIPTION The BA584G is a field mounting general purpose, two input Rate Totaliser which will function with a wide variety of sensors. The instrument can display rate of flow and total flow of the two inputs and their sum or difference. This abbreviated instruction sheet is intended to assist with installation, a comprehensive instruction manual describing system design and configuration may be downloaded from the BEKA website or may be requested from the BEKA sales office. 2. INSTALLATION The BA584G Rate Totaliser has a robust IP66 glass reinforced polyester (GRP) carbon loaded enclosure incorporating an armoured glass window & stainless steel fittings. It is suitable for exterior surface mounting in most industrial environments, or pipe mounting using an accessory kit. If the enclosure is not bolted to an earthed post or structure, the earth terminal on the cable entry bonding plate, which may be assembled on the inside or outside of the enclosure, should be connected to local earthed metalwork or to the plant's potential equalising conductor. Terminals A1, A2, A3 and A4 are only fitted when the Rate Totaliser includes optional alarms. Similarly terminals C1, C2, C3 and C4 are only fitted when the instrument has an optional 4/20mA output. See full manual for details. A A DISPLAY A A Step A Unscrew the four captive 'A' screws and separate the indicator assembly and the back-box. B B Insulated stud for joining cable screens Earth B stud B Step B Secure the enclosure back-box to a flat surface with M6 screws through the four 'B' holes. Alternatively use a pipe mounting kit. Step C Remove the temporary hole plug and install an appropriate IP rated cable gland or conduit fitting. Feed the field wiring through the cable entry. A A Step D Terminate field wiring on the instrument assembly. Replace the assembly on the enclosure back-box and tighten the four A A 'A' screws. Fig 1 BA584G installation procedure Abbreviated Instruction for BA584G general purpose field mounting two input Rate Totaliser The BA584G is CE marked to show compliance with the EMC Directive 2014/30/EU. P E Issue 2 18th July 2017 BEKA associates Ltd. Old Charlton Rd, Hitchin, Hertfordshire, SG5 2DA, UK Tel: +44(0)1462 438301 Fax: +44(0)1462 453971 e-mail: sales@beka.co.uk web: www.beka.co.uk 122 Optional 84 stainless 25 steel legend plate. 120 DISPLAY 90 19 Four M6 clearance holes for 106 surface mounting. Two M20 x 1.5 tapped cable 90 entries. Supplied with an IP66 stopping plug and one temporary hole plug. To remove the scale card carefully pull the tab perpendicularly away from the instrument assembly. See Fig 2 for the location of the scale card tab. E P Pulse input A + Add link to energise pulse input A Pulse input b + Add link to energise pulse input b Optional A1 + 6 A2 5 4 A3 + 3 A4 Alarm 1 1 2 Alarm 2 RS1 RS2 10 9 4/20mA 8 7 output P1 C4 P2 C3 + C2 C1 Optional + Power supply External reset + Pulse output Scale Card tab Fig 2 Dimensions and terminal connections EMC For specified immunity all wiring should be in screened twisted pairs with screens earthed at one point. DISPLAY RS2 RS1 6 5 4 3 10 9 8 7 + + Input A Flowmeter A 21 + Input b Flowmeter b + 24V dc Power supply Remote reset Sensor output Proximity detector Switch contact Open collector Input A Link 3 & 4 Voltage pulse Don't link Magnetic pick-off 3 & 4 Input b Link 7 & 8 Don't link 7 & 8 Fig 3 Typical measurement loop Scale card The instrument's units of measurement and tag information are shown above the display on a slide-in scale card. New instruments are fitted with a scale card showing the information specified when the instrument was ordered, if this was not provided a blank scale card will be fitted which can easily be marked on-site. Custom printed scale cards are available from BEKA associates. Fig 4 Inserting scale card into instrument assembly To replace the scale card carefully insert it into the slot shown in Fig 2. Force should be applied evenly to both sides of the scale card to prevent it twisting. The card should be inserted until about 2mm of the transparent tab remains protruding. 3. OPERATION The BA584G is controlled and configured via four front panel push buttons. In the display mode i.e. when the instrument is displaying flow the push button functions are: & or * Scrolls both displays between: Input A Input b Input A + b or Input A b which is configurable ) + & Grand total - shows lo followed by the least significant 8 digits of a 16 grand total. ) + * Grand total - shows hi followed by the most significant 8 digits of a 16 digit grand total. If buttons are pressed for longer than 10 seconds the grand total will be reset to zero if the grand total reset function clr gtot is enabled. To reset the grand total to zero from the operating mode press the ) and * buttons for ten seconds until CLr. no is displayed. Using the & or * button change the display to Clr . YE5 and press ) which will reset the grand total and restore the original display. & + * If the local total reset function clr tot is enabled in the configuration menu, simultaneously pressing the & and * buttons for more than three seconds allows total A, total b or both totals to be selected by operating the & or * button. Operating the ) button will then reset the selected total to zero and clear any stored output pulses. ( + & Shows each for 2 seconds: Firmware and version numbers Function of instrument: 2chtotal Options fitted -A Alarm outputs -P Pulse output (always fitted) -c 4/20mA output ( + & Provides direct access to the alarm setpoints when the Rate Totaliser is fitted with optional alarms and the AC5P setpoints function has been enabled. ( + ) Access to configuration menu Display DISPLAY mode ( ) ) code ( 0000 Security Code Enter code by pressing * or & & ( to move to next digit. Code 0000 allows direct access to the menu 4. CONFIGURATION Rate Totalisers are supplied configured as requested at time of ordering, if not specified default configuration will be supplied but can easily be changed on-site. Fig 5 shows the location of each function within the configuration menu with a brief summary of the function. Please refer to the full instruction manual for detailed configuration information and for description of optional outputs. Access to the configuration menu is obtained by pressing the ( and ) buttons simultaneously. If the Rate Totaliser's security code is set to default 0000 the first parameter function will be displayed. If the instrument is protected by a security code, code will be displayed. The four digit code must be entered to gain access to the menu. * Followed by identical function for input b When fitted with optional alarms functions appear here When fitted with optional 4/20mA output functions appear here () ) & function * & input-a * * ) ) ) ) ) ) ) ) ) ) ) ) & update * & count * & di5p-1 * & di5p-2 * & dP * & ** & factor-a ** & 5cale . t-a ** & 5cale . r-a t-ba5e * & ** & filter-a ** & clp. off-a Loc clr * ) ) ) ) ) & e clr * & pul5e op * & clr gtot * & code * & r5et def * () 5td () ) inp.type * & debounce () 0 . 5 () a : b () total () 5td () 0000 . 0 () 001 . 00 () 001 . 00 () 001 . 00 () tb-01 () 24 () 0000 . 0 () ) clr tot * & clr gtot () ( r5et-both () no () 0000 () 0000 () () () () () op.col default off off 0000 Function * or & to select Function of instrument 5td linear lin 16 segment lineariser Input-A * or & to select Debounce input-A * or & to select Input type op.col Open Collector. volt5 l Pulse <1V >3V volt5 h Pulse <3V >10V coil Magnetic pick-off. pr.det Proximity detector. contact Switch contact. level of debounce. default light heavy Update * or & to select interval between display updates, may be set to 0.5, 1, 2, 3, 4 or 5 seconds. Count Upper Display Lower Display * or & to select arithmetic relationship between input A and input b may be set to a : b Input A + Input b a : -b Input A - Input b * or & to select display whether rate or total is shown on upper display * or & to select label permanently identifies upper display. off display off 5td alternates between display and identification Decimal point * or & to select position of decimal point and ( to toggle between rate and total displays. K-factor input-A * or & to adjust value and ( to move to next digit or decimal point. Note: When lin is selected 16 values for factor-a may be entered each starting at a specified rate display Total scale factor input-A Divides factor-a output to produce required total display. Press * or & to adjust value and ( to move to next digit or decimal point. Rate scale factor input-A Divides factor-a output to produce required rate display. Press * or & to adjust value and ( to move to next digit or decimal point. Timebase * or & to select rate display timebase. tb-01 for flow/sec tb-60 for flow/min tb-3600 for flow/hour Filter input-A * or & to adjust value of each digit and ( to transfer control to the next digit. First digit: filter magnitude Second digit: step response Note: While making adjustments the filtered rate display is shown on lower display so stability can be assessed Clip-off input-A Rate display below which totalisation is inhibited Press * or & to adjust value and ( to move to next digit. Local total Local grand reset total reset * or & * or & to turn the to turn the local total local grand reset function total reset on or off. function When on is on or off. selected, Total A, When on, Total b or both grand total totals may be display may reset when be reset when * and & ) and * are pressed are pressed simultaneously simultaneously for more than 3 for more than 10 seconds in the seconds in the display mode. display mode. External reset * or & to select clr a nb clr a clr b Reset action when external reset contacts are closed. Clear grand total Press & or * to select ye5 to reset grand total to zero Confirm instruction by entering 5ure. Press & or * to adjust each digit and ( to move to next digit Define Security Code Enter by pressing & or * and ( to move to next digit. Reset configuration to factory defaults Confirm instruction by entering 5ure. Press & or * to adjust each digit and ( to move to next digit Unless otherwise specified menu functions are shown on the upper display ) ) ) ) & enbl * & 5ource * & divide * & duration * () () () () off 5caled 1000 25 Manuals and datasheets can be downloaded from http://www.beka.co.uk/ba584g Fig 5 Configuration menu Pulse Enable * or & to toggle between on and off Source of output pulse * or & to select pulse source 5caled Input pulse frequency may be divided and duration extended OR direct-a direct-b Divides scaled output pulse * or & to select frequency dividing factor for scaled output pulse. 1 10 100 1000 10000 Retransmission of input-A or input-b without scaling Duration of each pulse * or & to select duration of scaled output pulse in ms. 0.1 0.5 1 2.5 5 10 25 50 100 250 500 5caled is not These functions only appear in available when sub-menu when pulse source a : -b is selected is conditioned as 5caled. in the Count function.