Marco FRIIA HC: Stylish Undercounter Hot/Cold Water System
A stylish, flexible undercounter hot/cold water system for higher-volume sites, such as hotels, cafes, or offices.
Hot: 28 litres per hour | Cold: 35-40 litres per hour
Product Overview
The FRIIA HC is designed for efficiency and style, providing both hot and cold filtered water from a single, compact undercounter unit. It is ideal for environments requiring a consistent supply of chilled and hot water, such as busy cafes, hotels, and offices.
Key Components and Models:
- 2B Font (Order Code: 1000868)
- Chiller (Order Code: 1000860)
- MIX UC3 (Order Code: 1000880)
- MIX UC8 (Order Code: 1000887)
- System Set-Up
Complete Bundle Order Codes:
- FRIIA HC: 5000862
- FRIIA HC Plus: 5000865
Chiller Specifications
Product Info | Size (Dimensions D x W x H mm) | Performance Specs (L/HR) | Performance Specs (CUPS/HR) | Plumbing, Electrical and Technical Specs (Power @220v) | Plumbing, Electrical and Technical Specs (Compressor Req's) | Plumbing, Electrical and Technical Specs (Charge Refrigerant) |
---|---|---|---|---|---|---|
Chiller (1000860) | 436 x 259 x 455 | 30-40 L/HR (based on incoming water temp of 15°C and output water temp of 5-7°C) | 175-235 (ΔT = 10 °C) | 180 W | 3/4" BSP, 1/8hp | 45g R290 |
A minimum operating pressure of 2 bar or 28 psi downstream of filter is required for optimum output l/min.
Boiler Specifications
Product Info | Size (Dimensions D x W x H mm) | Performance Specs (Immediate Draw Off) | Performance Specs (L/HR) | Performance Specs (CUPS/HR) | Plumbing & Electrical Reqs (Power @220v) | Plumbing & Electrical Reqs (Plumbing Req's) |
---|---|---|---|---|---|---|
MIX UC3 (1000880) | 385 x 210 x 444 | 3L | 28L | 156 | 2.8kW | 3/4" BSP |
MIX UC8 (1000887) | 385 x 210 x 617 | 8L | - | - | - | - |
Font Specifications
Name | Order Code | Dimensions Incl. Drip Tray (D x W x H mm) | Dimensions Excl. Drip Tray (D x W x H mm) | Tap to Counter (mm) |
---|---|---|---|---|
2b Font | 1000868 | 168 x 120 x 286 | 138 x 30 x 286 | 247 |
Packaging Dimensions
Name | Packaging Dimensions (L x W x H mm) | Weight |
---|---|---|
Font | 290 x 570 x 215 | 1.65kg |
Chiller | 500 x 320 x 520 | 35kg |
MIX UC3 | 450 x 290 x 540 | 11kg |
MIX UC8 | 450 x 290 x 700 | 14kg |
Installation Requirements
Ventilation Requirements
Front Ventilation: Ventilation grilles cut out of standard cabinet door.
Side Ventilation: Ventilation grilles cut out of standard 600mm cabinet. Grilles may be fitted on either side as long as they ventilate into an open unobstructed area.
Base Ventilation: Ventilation grilles cut in base panel and base plinth, a grille must also be cut out at the top of the cabinet. At least 2 x vents 260mm/10.2" w x 65mm/2.5" h. The cabinet may be ventilated in many ways provided there are cut outs placed near the base and another near the top of the cabinet to take advantage of natural circulation.
Unpacking Instructions
- The chiller must be handled only in a vertical position. Transporting the appliance in a horizontal position can cause severe damage to the refrigerator.
- Remove the exterior and interior packing. Packing materials (especially any plastic bags) should be stored out of the reach of children, as a potential source of danger. When disposing packaging parts, please follow current regulations on the matter, separating carton from plastic parts.
- Always check that the equipment that is delivered corresponds to the model indicated in the accompanying document.
- The equipment is shipped in a cardboard box. Once the packaging has been removed, check the equipment has not been damaged in transit; if damage is found, notify the carrier.
Electrical Installation Procedure
When installing the machine, always observe the local regulations and standards. The appliance is supplied with a moulded power cord. A suitable mains power supply socket should be available within easy access of the appliance so that it can be disconnected easily after install. The standard machines are supplied with a UK 3-pin plug. For EU models a 2-pin CEE-7 plug will be supplied. US models will be supplied with the suitable plug. A suitable mains power supply socket should be available within easy access of the appliance so that it can be disconnected easily after install. The wires from the font are terminated in a Mini Fit connector which will plug into a similar Mini Fit connector mounted on the top lid of the undercounter boiler.
Plumbing Installation Procedure
- Ensure that the equipment is installed according to local plumbing & water regulations.
- Fit a stop valve on a cold water line and attach a 3/4" BSP male fitting, (eg. 3/4" x 1/2" 311 or washing machine type stop valve). Suitable fittings are supplied with the kit to attach to the 3/4" BSP fitting to connect the supplied 3/8" hose.
- Connect water supply lines following the installation drawings, as per installation guide (starting page 14).
- In case filter systems are used verify that they satisfy the requirements of the legislation in force.
- If the filter is new, turn on water and flush at least 10 litres (2.5 gallon) through the filter before to connect it to the cooler; if the filter is a used one, connect water inlet to the chiller.
- To ensure that the maximum value of pressure of 3 Bar is not exceeded the chiller integrates a pressure reducer.
- Turn on the water to flush any impurities, dust etc from the inlet hose and water pipe. Allow several litres through. Especially for new installations.
Operating the Chiller/Carbonator for the First Time
- Before connecting the appliance to the power source, let it stand upright for approximately 2 hours. This will reduce the possibility of a malfunction.
- Check that all installation procedures have been carried out.
- Ensure water inlet is open.
- Before supplying power to the unit check water and Carbon Dioxide lines do not leak.
- Plug the chiller into a suitable socket switch ON/OFF switch on the rear of the chiller to ON position. The "Power ON Status" light will light-up.
- When the unit is on, the carbonation pump starts to fill. The carbonation device stops when it reaches the maximum level.
- Once water and CO₂ are connected, open the vent on top of the Chiller by pulling the ring. This operation allows the escape of any air bubbles present inside, which would affect the carbonation adversely.
- On the pressure reducer knob, adjust CO₂ pressure to a value between 50 and 65 PSI (350 and 450 kPa) (3.5 - 4.5 bar). This value depends on the temperature of the water and on the ambient temperature. The temperatures correspond to the CO₂ pressure.
- To enable filling the lines, open the two lines in the following order: cold sparkling water and cold natural water, until the flows appear regular and without the presence of air, in each case deliver and discharge at least 5 litres of water from each line.
- At this point you can dispense water.
System Overview
Counter Cut-Outs
Diagrams showing counter cut-out dimensions for the drip tray and the main unit are provided.
Radius of Maximum Font Placement
Diagram illustrating the maximum font placement radius within a standard 800mm high cabinet.
Cabinet Requirements
Minimum cabinet dimensions: 800mm (height) x 600mm (width) x 600mm (depth) with 100mm clearance around machines on all sides.
Operating Environment
Cannot exceed a temperature of 35°C.
Ventilation
Diagrams illustrating ventilation requirements for the FRIIA system, indicating the need for two ventilation points. It is recommended to remove the back of the cabinet where possible.
FRIIA Performance & Maintenance
FRIIA Output Volume
A chart displays the FRIIA chilling capacity based on flow rate of 1.4L/min and ambient temperature of 20-25°C, showing output volume (L/H) against incoming temperature (°C) for different output temperatures (3°C, 5°C, 7°C).
Sanitisation Accessories
Accessory | Order Code |
---|---|
Sanitisation Kit: Internal Water Cooler Sanitising Solution 1L + Chiller Best Service Cartridge | 8000900 |
Internal Water Cooler Sanitising Solution 1L | 8800125 |
Scaleclean 1kg Descaler (5 uses) | 8000260 |
Chiller Best Service Cartridge | 8000522 |
Scaleclean 200g Descaler (1 use) | 8000270 |
How to Clean FRIIA
- Wipe down font daily with non-abrasive cleaner.
- Sanitise the system every 6 months, after a filter change or after a period of inactivity (more than 72 hours).
Maintenance
- Marco recommends using both HOT (scale reducing filter if limescale is present) and COLD (carbon block for taste and odour) water filters for FRIIA. Please contact Marco for advice on the best water filter.
- Descale the MIX boiler if scale is present in the water.
For more information visit www.marcobeveragesystems.com