✔️ samsara

AG53-Powered Asset Gateway

FOR TRAILERS | AG53 DATASHEET

OVERVIEW

The Powered Asset Gateway for Trailers is ideal for tracking and monitoring dry-vans, chassis, flatbeds, reefers, tankers, and other specialty trailers. It features a ruggedized, waterproof enclosure, fast and precise location tracking even in low coverage areas, and discreet undercarriage installation for seamless plug-and-play deployment.

The Powered Asset Gateway for Trailers enables improved operational efficiency, maintenance, safety, and compliance to manage trailer fleets at scale.

SUPPORTED TRAILER TYPES

HIGHLIGHTS

DESIGNED FOR RAPID ROI

Technical Specifications

CELLULAR DATA CONNECTIVITY

Cellular Data: LTE Cat M1 and NB-IOT

Operating area: United States, Canada, Mexico,

Offline Storage: Built-in flash memory to store data when Internet connectivity is unavailable.

Secure Communications: All Internet connectivity secured via HTTPS with TLS encryption

LOCATION TRACKING

Real-time tracking: Multi-constellation GPS for high resolution, real-time geolocation with robust coverage in low signal environments and internal antenna for discreet installation.

POWER *

* Typical battery lifetimes provided. Actual battery life is affected by extreme cold, cellular signal strength, and accessory sensor utilization

Sources: Designed for use with external power and Smart Trailer ABS Cables, intermittent external power, or battery backup applications (via internal lithium-ion battery)

External Power: 9-60V DC

Power draw: 200 uW (sleep) to 5,000 mW (peak); normal operation at 200mW

Lithium-Ion Battery: 3 Ah internal battery capacity

Lasts over 12 months (2 check-ins per day) when fully charged

Enabling Find My Asset (US only) reduces battery life, approximately 40%, if activated at installation and left on throughout the product life without recharge

For questions about the safe use of lithium-ion battery powered devices, please consult your company's safety department

Charging: Average unit will require 10 hours of charge for full battery charge

ENCLOSURE

Material: UV-stabilized polycarbonate

Dimensions: 124 x 81 x 35 mm

Weight: 192 g

Operating temperature Operation: -40° to 60°C externally powered, -20° to 60°C discharging on battery, 0°C to 45°C charging

IP Rating: IP67 (weatherproof and water resistant up to 1m submerged) IP69k (highest grade resistance to high pressure and high temperature washdown)

Hazardous locations: Certified Class I Division 2 Group A-D T6 (C1D2) for hazardous locations when used with special bracket (ACC-AG-BHZB)

SAMSARA CLOUD SOFTWARE FEATURES

Features:

Technical Specifications (cont'd)

CABLES (one per gateway required)

ACCESSORIES

Image of the Samsara AG53-Powered Asset Gateway, a black rectangular device with a camera lens-like sensor on top, a QR code, and a port at the bottom. The Samsara logo is visible.
Diagram showing the dimensions of the AG53-Powered Asset Gateway. The main body is 124mm x 81mm x 35mm. Mounting holes are indicated as 2x Ø4mm, spaced 72mm apart.

Regulations

IC REGULATIONS

This device complies with Industry Canada's license-exempt RSSs. Operation is subject to the following two conditions:

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

This equipment complies with Innovation, Science and Economic Development Canada RF exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated to ensure a minimum of 20 cm spacing to any person at all times.

CAN ICES-3(B)/NMB-3(B)

IC Radiation Exposure Statement:

This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body.

IC Déclaration d'exposition aux radiations: Cet équipement est conforme Canada limites d'exposition aux radiations dans un environnement non contrôlé. Cet équipement doit être installé et utilisé à distance minimum de 20cm entre le radiateur et votre corps.

FEDERAL COMMUNICATION COMMISSION INTERFERENCE STATEMENT

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  1. Reorient or relocate the receiving antenna
  2. Increase the separation between the equipment and receiver
  3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
  4. Consult the dealer or an experienced radio/TV technician for help

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.

FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

PDF preview unavailable. Download the PDF instead.

data-sheet-powered-asset-gateway-trailers-AG53 Skia/PDF m126 Google Docs Renderer

Related Documents

Preview Samsara AG51 Unpowered Asset Gateway Datasheet
Datasheet for the Samsara AG51 Unpowered Asset Gateway, a wallet-sized tracker for monitoring mobile assets like containers, construction equipment, and dumpsters. Features customizable GPS check-ins, user-replaceable AA batteries, and a waterproof enclosure.
Preview Samsara VG55 Vehicle Gateway Datasheet and User Manual
Datasheet and user manual for the Samsara VG55 Vehicle Gateway, an advanced sensor platform for fleets offering real-time location, analytics, and connectivity.
Preview Samsara VG54 Vehicle IoT Gateway: Datasheet and User Manual
Comprehensive datasheet and user manual for the Samsara VG54 Vehicle IoT Gateway, detailing its features, specifications, installation, and regulatory compliance for fleet telematics.
Preview Samsara VG34 & VG54 Vehicle Gateways Datasheet
Datasheet for Samsara VG34 and VG54 Vehicle Gateways, detailing features, specifications, data sources, connectivity, power, enclosure, and software capabilities for fleet management.
Preview Samsara Vehicle Gateway CBL-VG-CAUX Installation Guide
Installation guide for the Samsara Vehicle Gateway (CBL-VG-CAUX), detailing connection steps, wiring, pin assignments, and support resources for fleet management.
Preview Samsara Vehicle Gateway CBL-VG-CAUX Installation Guide
This guide provides instructions for installing the Samsara Vehicle Gateway (CBL-VG-CAUX), including wiring and connection details.
Preview Understanding the ELD Mandate: Samsara's Compliance Solution Guide
A comprehensive guide to the Electronic Logging Devices (ELD) Mandate, explaining its purpose, applicability, timeline, and how Samsara's integrated fleet management solution ensures compliance while enhancing productivity and reducing operational costs.
Preview Samsara Environmental Monitor Installation Guide
Step-by-step instructions for installing the Samsara Environmental Monitor (EM21), including required components and setup for monitoring temperature and humidity.