Instructions for RIB models including: RIBTW2421B-BCIP BACnet IP Network Relay Device, RIBTW2421B-BCIP, BACnet IP Network Relay Device, IP Network Relay Device, Network Relay Device, Relay Device, Device
kele.com | Functional Devices RIBTW2421B-BCIP | Relays & Contactors | Power Relays
File Info : application/pdf, 1 Pages, 466.03KB
DocumentDocumentFunctional Devices, Inc. 101 Commerce Drive Sharpsville, IN 46068 www.functionaldevices.com sales@functionaldevices.com Office: (765) 883-5538 Fax: (765) 883-7505 Toll Free: (800) 888-5538 INTELLIGENT FIELD DEVICE RIBTW2421B-BCIP BACnet IP Network Relay Device, One Binary Output + Override, One Binary Input, 24 Vac/dc / 120-277 Vac Power Input, NEMA 1 Housing RJ45 LAN ** CAUTION! NO POE ** This RJ45 connection is for LAN only. Do NOT connect POE Reset Pushbutton { Dry Contact Binary Input { 24 Vac/dc Relay Common Override 2 1 1 0 4.00" .20" .20" 0.2" .20" .20" .44" .56" 0.50" NPT 4.00" .44" .56" Red Black Blu Yel Org Neutral or 120-277 N/C C N/O Other Phase Vac 2.00" 1.81" 1.00" SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Contact Ratings: BACnet® Details: Expected Relay Life: 10 million cycles minimum mechanical 20 Amp Resistive @ 277 Vac Device ID will default Operating Temperature: -30 to 140° F 20 Amp Ballast @ 277 Vac to 277XXX where XXX is Humidity Range: 5 to 95% (noncondensing) 16 Amp Electronic Ballast @ 277 Vac (N/O) the decimal value of the Operate Time: 18ms 10 Amp Tungsten @ 120 Vac (N/O) last octet of the device's Green LED: Network Communication 1110 VA Pilot Duty @ 277 Vac MAC address Red LED: Relay Status 770 VA Pilot Duty @ 120 Vac Yellow LED: Link Status Blue LED: Heartbeat 2 HP @ 277 Vac 1 HP @ 120 Vac Examples: Pink LED: Binary Input Status Dimensions: 4.00"H x 4.00"W x 1.81"D with 0.50" NPT hub Origin: Made of US and non-US parts Wires: 16, 600V Rated Approvals: CE, UL Listed, UL916, C-UL, RoHS Power Input Ratings: 80 mA @ 24 Vdc 135 mA @ 24 Vac 19 mA @ 120-277 Vac MAC Address D8:47:8F:23:97:9E Hexadecimal 9E = Decimal 158 Device ID 277158 Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Ethernet Cable Power Input: 24 Vac/dc; 120-277 Vac; 50-60 Hz MAC Address D8:47:8F:23:9F:20 Hexadecimal 20 = Decimal 32 Device ID 277032 Notes: Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used Device ID can be changed with DIP SWITCHES* RELAY STATE** with any dry contact switching device, such as a a BACnet configuration tool or 1 2 0 1 Auto current sensor, to report back to the network. When connecting 24 Vac to both the RIB(s and a on the product's webpage via an internet browser. 1 X Override on half-wave device, damage to device can occur. This model utilizes: 0 0 Override off Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 BO1 (Relay output) BI1 (Dry Contact Binary Input), * 0 = Open ; 1 = Closed note below. ^^ NP1 (Network Port Object) ** Device must be powered for override PIC Statement available on website RIBTW2421B-BCIP Half-Wave Device See Bulletin B3703 for more information 24 Vac 24 Vac/dc Comm 24 Vac Comm ^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s). IN4004 2024.07.26