First Alert 2-IN-1 SMART SMOKE & CARBON MONOXIDE ALARM

Model SMCO410 | Cat. 1048325

⚠️

Be Notified Whether Home or Away

Receive alerts if smoke or CO is detected.

?❌

No Battery Replacements

Or chirps* for the life of the alarm.

End-of-Life Warning

Lets you know when it's time to replace.

[Z-Wave Plus]

Z-Wave Plus Enabled

Operates with certified Z-Wave devices.

[Works with Ring]

Works with Ring

Ring Alarm Required.

ARCHITECTURAL AND ENGINEERING SPECS

The combination smoke and CO alarm shall be a First Alert Model SMCO410 and shall provide at a minimum the following features and functions:

  1. A photoelectric smoke sensing chamber and an electrochemical CO sensor.
  2. Operates with 3rd party, certified Z-Wave devices enabled with the First Alert protocol.
  3. Uses a P-Horn that is 3kHz.
  4. The CO sensor is adjusted not to detect CO levels below 30 PPM and will not alarm when exposed to constant levels of 30 PPM for 30 days. It will alarm at the following levels: 400 PPM CO between 4 and 15 minutes, 150 PPM CO between 10 and 50 minutes and 70 PPM CO between 60 and 240 minutes.
  5. The unit shall have an "10 Year End of Life" signal. This signal should be capable of temporarily being silenced for up to 2 days. After about 2 days, the signal will resume. After about 2 weeks the signal cannot be silenced.
  6. A fully screened sensing chamber to resist entry of small insects.
  7. Powered by a sealed 10-year lithium powercell with a tamperproof design. The tamperproof design shall not allow the powercell to be removed. A low power warning indicator shall cause the alarm to "chirp" when it reaches the end of its service life and needs to be replaced. Upon end of life, the unit shall meet UL requirements for disabling the alarm and the non-reinstallation of unit to mounting bracket.
  8. A visual Green LED power-on indicator to confirm unit is receiving power or is in alarm.
  9. Two Silence features - Low Battery Silence: Silence low battery chirp for up to 8 hours. Alarm Silence (Smoke/CO): Temporarily silence unwanted nuisance alarms.
  10. Two Locking features - tamper resistant locking pins that lock battery drawer and/or alarm to mounting bracket.
  11. The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and relative humidity between 10% and 95%.
  12. The unit shall contain mounting hardware and shall be listed for wall or up to 12" ceiling mounting.
  13. The unit shall at a minimum meet the requirements of UL217, UL2034, CSFM, FCC, IC, Z Wave Plus, NFPA 72, and NFPA 720.

INSTALLATION OF ALARM

Installation of this alarm must conform to NFPA 72. Always check your local building codes. Follow all instructions for placement as outlined in the user's manual in sections titled "Recommended Locations for Smoke Alarms" and "Locations to Avoid for Smoke Alarms".

TECHNICAL SPECS

FeatureSpecification
Alarm Dimensions5.0" Dia. x 2.12" H
Weight0.40 lb
Battery3V Lithium
Temperature Range40°F (4°C) to 100°F (38°C)
Humidity Range10% to 95% relative humidity (RH)
Audio Alarm85dB at 10 feet
Wireless FrequencyZ-Wave 500 Series
Wireless Range131.24 ft
Test/SilenceElectronically simulates smoke and CO condition, causing the unit to alarm. Press and hold test/silence button.
Alarm ResetAutomatic when smoke and/or CO clears
Smoke SensorPhotoelectric
CO SensorElectrochemical
Indicator Lights/ Sounds
  • DC Power: Flashes Green every minute
  • Smoke Alarm: 3 Beeps, Flashes Red
  • CO Alarm: 4 Beeps, Flashes Red
  • Malfunction: 3 "Chirps" every Minute – Replace Alarm
  • End of Life: 5 "Chirps" every Minute – Replace Alarm
ListingListed to UL217 and UL2034 Standards

SYSTEM REQUIREMENTS

Android or iOS Device

Ring Alarm or Ring Alarm Pro Security Kit with Alarm Smoke and CO Listener required.

PDF preview unavailable. Download the PDF instead.

SMCO410 SpecSheet Adobe PDF Library 17.0 Adobe InDesign 20.2 (Macintosh)

Related Documents

Preview First Alert SMCO500V Smoke & Carbon Monoxide Alarm User's Manual
Comprehensive user manual for the First Alert SMCO500V Smoke & Carbon Monoxide Alarm. Learn about installation, features, testing, maintenance, troubleshooting, safety information, and warranty.
Preview First Alert SMCO410 Smoke & Carbon Monoxide Alarm User Manual
Comprehensive user manual for the First Alert SMCO410 Smoke and Carbon Monoxide Alarm with a 10-year sealed battery. Learn about installation, features, testing, maintenance, and safety tips for your home.
Preview First Alert SMCO410 Smoke and Carbon Monoxide Alarm User Manual
Comprehensive user manual for the First Alert SMCO410 10-year sealed battery smoke and carbon monoxide alarm, covering installation, operation, maintenance, troubleshooting, safety tips, and warranty information.
Preview First Alert SMCO410 Smoke and Carbon Monoxide Alarm User Manual
Comprehensive user manual for the First Alert SMCO410 Smoke and Carbon Monoxide Alarm, detailing installation, operation, maintenance, troubleshooting, and warranty information.
Preview First Alert SC5 Smart Wired Smoke and Carbon Monoxide Detector
Comprehensive overview of the First Alert SC5 smart wired smoke and carbon monoxide detector. Details features like quick connect, wired interconnection, voice alerts, remote notifications, and backup battery, alongside technical specifications and installation guidance.
Preview First Alert SC5 Battery Smart Smoke & Carbon Monoxide Alarm - Product Specifications
Detailed specifications and features for the First Alert SC5 Battery Smart Smoke & Carbon Monoxide Alarm (Model SMCO600NV-A), including technical specs, installation guidelines, and system requirements.
Preview First Alert SC5 Wired Smart Smoke & Carbon Monoxide Alarm Installation and Reference Manual
Comprehensive guide for installing, operating, and maintaining the First Alert SC5 Wired Smart Smoke & Carbon Monoxide Alarm, featuring voice alerts, hardwire interconnectivity, and mobile notifications for enhanced home safety.
Preview Carbon Monoxide Alarm FAQ: Installation, Testing, and Placement
Frequently asked questions about carbon monoxide alarms, covering installation, placement, testing, troubleshooting chirping, and distinguishing false alarms. Information from First Alert and NFPA guidelines.