IX SERIES
IP Video Intercom System
IXW-MA and IXW-MAA Programming Guide

Table of Contents

Pages 2-5 Page 5-6 Page 7 Page 8-9 Page 9-10 Page 11

Programming a New System that Includes the IXW-MA or IXW-MAA - Create a New System Using the Support Tool Programming Wizard
Adding the IXW-MA to an Existing System - Adding the IXW-MA to an existing system using the Support Tool Programming Wizard
SIF Settings - Configure IX Series stations to interact with the IXW-MA
SIF Settings for IX-BA, IX-DA, IX-MV Stations - Configuring legacy IX Series stations to interact with the IXW-MA
Relay Output Settings - Configuring for Door Release or External Signaling
Uploading the Settings - Uploading Settings to Stations and Exporting System Configuration

ATTENTION: This is an abbreviated programming manual addressing basic IP Relay program settings using IX Support Tool. A complete set of instructions (IX Web Setting Manual / IX Operation Manual / IX Support Tool Setting Manual) can be found at www.aiphone.com/IX.
06/23 1

Introduction
The IXW-MA and IXW-MAA adaptors have 10 relay outputs that can be triggered by an event on an IX Series station. This guide will walk through programming a system to include either adaptor, as well as programming the outputs. Because the IXW-MA and IXW-MAA function the same way, and IX Support Tool considers them both an IXW-MA for programming purposes, this guide will only refer to the IXW-MA.
Programming a New System to Include an IXW-MA
If the system has already been configured without the IXW-MA, skip to Page 5.
Step 1: System Settings
1.1 - Create New System
Open IX Support Tool. If the New System window does not open, select File from the top menu bar, then Create New System.
1.2 - New System
Enter a System Name under System Settings and select the quantity for each station type under IX Support Tool Settings.
1.3 - Creating the System
Once each field of the New System page is filled appropriately, click Next .
Step 2: Station Customization Support Tool will provide each station a default Station Name, four-digit Number, and IP address starting from 192.168.1.10. To edit this information, click Station Details in the Advanced Settings section, shown below. To use the default information created by Support Tool, skip to Step 3.
2.1 - Station Details
Click Station Details to edit the Number, Name, and IP Address for each station.
06/23 2

Programming a New System to Include an IXW-MA
Step 2: Station Customization (continued) 2.2 - Edit Station Details
Edit the Number, Name, IP Address, and Subnet Mask for each station as needed. Note: Do not fill in the Hostname.
2.3 - Update Station Details
Click OK to update the station details that were edited.
Step 3: Association The association process will link the information created in Support Tool with a station found on the network. Once associated, the station will receive its station name and network information once it finishes rebooting.
3.1 - Select
Select the setting file to be associated from the Station Settings List.
3.2 - Select
Select the scanned station to be associated with the selected file from the Station List.
3.3 - Apply
Click Apply to associate the selected station with the selected file. Repeat until all stations are associated.
06/23 3

Programming a New System to Include an IXW-MA

Step 3: Association (continued)
3.4 - Status
Confirm that each station has been successfully associated in the Status column.
3.5 - Next
If all stations show Success, click Next .

Scroll Down

Scroll Down

Step 4: Setting File Upload
Once each station has been associated with its individual station information, the setting file containing the rest of the system's information will need to be uploaded to each station. To upload the setting file, the programming PC will need to be in the same subnet as the associated stations. The PC's current IP address is listed in the bottom left-hand side of this window. The stations will not operate until the setting files have been uploaded.
4.1 - Select
Stations can be selected individually, or by Type. Choose All from the Select Station by Type drop down menu to upload to all stations. Click Select .
4.2 - Start Upload
Once station Status shows Available, click Start Upload .
4.3 - Next
After successful upload, click Next .

Note:
The progress of each station will be displayed in the Status column. Unavailable stations may still be rebooting from the association process. If a station has rebooted and is still unavailable, ensure the programming PC is in the same subnet as the station.

06/23 4

Programming a New System to Include an IXW-MA
Step 5: Export Settings The final step in the Programming Wizard is to create a copy of the system's setting file and export it to a secure location or external drive. 5.1 - Export
Click Export .
5.2 - Select Folder
Select location to save the file. Click OK .
5.3 - Finish
Click Finish .
Note: If the original program file is lost, or Support Tool is moved to a different PC, this copy can be used to access the system programming to make changes or adjustments.
Adding an IXW-MA to an Already Existing System
Skip this section if the IXW-MA has already been added to the system. The steps below will walk through adding an IXW-MA relay adaptor to an existing system. The IXW-MA should be connected to the same network as the existing system before proceeding. Open IX Support Tool and select the existing system to be edited.

A - System Configuration
Click Tools from the top menu bar and select System Configuration.

B - Add New Station
Click Add New Station .
Continue on page 6.

06/23 5

Adding an IXW-MA to an Already Existing System
C - Select Station Type
Select the IXW-MA using the Station Type drop down and enter the quantity of stations to be added. Click Add .
D - Edit Station Information
Edit the Number and Name for the new station to be added.
E - Add
Click OK to add the station.
The added station will appear in the Station Settings list with the number and name assigned. Support Tool will automatically assign an IP address, though this can be changed later.
F - Select
Select the setting file for the IXW-MA from the Station Settings List.
G - Select
Select the IXW-MA to be associated with the selected file from the Station List.
H - Apply
Click Apply to associate the selected station with the selected file.
I - Status
Confirm that the IXW-MA has been successfully associated in the Status column.
J - Next
If stations show Success, click Next .

Scroll Down

Scroll Down

06/23 6

SIF Settings (Go to Page 8 for IX-BA, IX-DA, and IX-MV Settings)
Step 1: Enabling SIF Functionality for IX Series Stations
The IXW-MA will only recognize the change contact transmission trigger. All other transmission triggers will be ignored by the adaptor. The transmission trigger is sent from the station receiving the release command to the IXW-MA. The following process outlines the settings required to send this SIF event by the door station. From the menu on the left, expand Function Settings and select SIF.
Note:
These settings will need to be configured for each source of the SIF
event, not the IXW-MA.

1.1 - Enable 1.2- Program Type

Enable SIF Functionality.

Enter 0100.

1.3 - IPv4 Address
Enter the IPv4 Address of the IXW-MA.

1.4 - Destination Port
Enter 65013 if SSL is Disabled, Enter 65014 if SSL is Enabled.

1.5 - Connection
Use the Connection dropdown menu to select Socket.

1.7 - Scroll Right
Scroll the window to the right until the Change contact column is displayed.

1.8 - Change Contact
Check the Change contact box for each station that will communicate with the IXW-MA.

1.9 - Update
Click Update to store the settings and continue to the next step.

06/23 7

SIF Settings for IX-BA, IX-DA, and IX-MV Stations the IXW-MA
Note: Only these models of stations need to have a SIF.ini file uploaded to them. SIF uploads will always fail on other station models. See the previous page for SIF programming steps for those stations.
Step 1: Creating the SIF.ini File Creating a line of code, in the form of a .ini file, is required to allow an IX Series (IX-DA, IX-BA, IX-MV) station to communicate to the IXW-MA. The example below is shown using a common text editor (e.g. Notepad), and saving it with a .ini extension.

Program Type: IXW-MA IP Address: Destination Port: SSL Y/N :
Example Text File:

Must be binary number 0100. IP address assigned to the IXW-MA . Port number assigned on the IXW-MA. Enter 65013 if SSL is disabled, 65014 if SSL is enabled. Input 0 if disabled, input 1 if enabled.
0100,192.168.1.17,65014,1

Program Type

IXW-MA IP Address

Destination SSL

Port

Y/N

Save the SIF file with a .ini extension (.ini must be typed manually) to a location on the PC being used for programming the IX Series stations. This file must be uploaded to each device associated with the IXW-MA using the instructions that follow.
Step 2: Enabling SIF Functionality for IX Series Stations

2.1 - SIF Settings
From the menu on the left, expand Function Settings and select SIF.

2.2 - Station View
Click Station View .

2.3 - Select Station
Use the Number drop-down under Select Station to Edit and choose the IX Series door station. Click Select and ensure that the door station is shown in upper left of the screen.

2.4 - Enable SIF
Select the Enable radio button for SIF Functionality.

06/23 8

SIF Settings for IX-BA, IX-DA, and IX-MV Stations the IXW-MA
Step 2: Enabling SIF Functionality for IX Series Stations (continued)
2.5 - Scroll Down
Scroll down until SIF File Management is displayed.
2.6 - Browse
Click Browse to select the SIF.ini file that was created in Step 1.
2.7 - Upload
Click Upload to send the selected file to the station.
2.8 - Update
Click Update to save changes.
IXW-MA Relay Output Settings
Step 1: Configuring individual IXW-MA Relays

1.1 - Relay Output
From the menu on the left, expand Option Input / Relay Output Settings and select Relay Output.

1.2 - Select Relay Output
Use the Relay Output drop-down menu to select a relay output.

1.3 - Function
Use the Function drop-down menu to select Contact Change SIF Event for the IXW-MA.

06/23 9

IXW-MA Relay Output Settings
Step 1: Configuring the individual IXW-MA Relays (continued)

1.4 - Contact Change SIF Event
Scroll the window to the right until Relay Output 1, Contact Change SIF Event is displayed.

1.5 - Select a Station
Click Open and select the Station Number of the station to communicate with the IXW-MA.

Uploading Settings to Stations

1.6 - Update
Click Update to save changes.

1.1 - Upload
Navigate to File on the top menu bar and select Upload Settings to Station.

1.2 - Select
Stations can be selected individually, or by Type. Choose All from the Select Station by Type drop-down menu to upload to all stations. Then, click Select .

1.3 - Settings
Click Settings to upload the Setting Files to the selected stations.

06/23 10

Exporting the Settings

1.1 - Export Settings
Navigate to File on the top menu bar and select Export System Configuration.

1.2 - Export
Click Export .

1.3 - Select Folder
Select location to save the file then click OK .

1.4 - Finish
Click Finish .

Note:
If the original program file is lost, or Support Tool is moved to a different PC, this copy can be used to access the system programming to add or remove a station, or to make programming changes.