Tenmars Integrating Sound Level Meter

ST-107/ST-107S User's Manual

1. Safety Precautions

When taking measurements:

The following symbols are used:

2. Preliminary Description

The Integrating Sound Level Meter can also survey: SPL(Lxyp), Lxmax, Lxmin, Leq, SEL (LAE), Lcpeak, RT60. It supports three types of frequency weighting (A, C, Z) and three types of time weighting (F, S, I) simultaneously. The dynamic range is over 100dB, eliminating the need to select a measuring range, making operation simple.

Applications: Evaluation of environmental noise, measurements of noise at workplaces, assessment of product noise.

2.1. Note

CAUTION: Failure to observe the warning and/or operation instructions may damage the instrument, its components, or the operator.

3. Preparation for Use

3.1. Initial

The instrument has been checked mechanically and electrically prior to shipment. Ensure it arrives undamaged. It is recommended to perform a quick check for any transport damage. If damage is found, contact the dealer immediately. Verify the packaging contents against the packing list in section 13.3.1. Contact the dealer immediately in case of discrepancies. For re-shipment, follow the instructions in the relevant chapter.

3.2. Supply Voltage

The instrument is powered by batteries. A low battery indicator will be displayed when batteries are low. Refer to the relevant chapter for battery replacement instructions. The instrument can also be powered by an external power supply (6~9V, 500mA maximum output current).

CAUTION: If the instrument will not be used for an extended period, remove the batteries to prevent acid leakage that could damage the instrument's internal components.

3.3. Calibration

The instrument complies with the technical specifications in this manual and is guaranteed for one year. Recalibration may be required after one year.

3.4. Storage

After storage in extreme environmental conditions exceeding the limits in paragraph 11.2.1, allow the instrument to return to normal measuring conditions before use.

4. Instrument Instructions

4.1. Instrument Description

4.1.1. Controls Description

The instrument features the following controls:

4.1.2. Display Description

The display shows various indicators:

4.1.3. ST-107S Microphone
Frequency (KHz) Deviation of pressure
0.25 0.0
1 -0.1
2 -0.5
3 -0.6
4 -0.9
5 -1.2
6 -1.7
7 -2.2
8 -2.8
9 -3.3
10 -4.1
12.5 -6.0

4.2. Measurement Procedures

The default test mode is Lxyp mode, A weighting, Fast weighting.

CAUTION: Wind blowing across the microphone can cause extraneous noise. If wind speed exceeds 10m/s, mount the windscreen to prevent undesirable signals. Keep the microphone dry and avoid severe vibration.

(Refer to EN-7, Fig.1 for windscreen attachment)

4.3. Data Hold

Press [HOLD] button to lock the display data; press again to unlock.

4.4. Maximum/Minimum

Press [MAX/MIN] button to enter MAX/MIN record mode. The instrument can store maximum/minimum data for up to 99 hours, 59 minutes, 59 seconds. Press [] button to end the measurement in advance.

4.5. Single Data Record

Press [REC/MEM] button each time to store the displayed reading and its memory location.

4.6. Viewing Logged Reading

4.7. Set Mode

Press [SET] button to enter set mode. Seven functions can be configured in set mode.

4.7.1. Clock Set

4.7.2. Auto Record Time Set

Minimum auto record time is 1 second; Maximum auto record time is 23 hours 59 minutes 59 seconds. Setting auto record time to 0 seconds disables the auto record function.

4.7.3. Auto Power Off Time Set

To disable auto power off, set the auto power off time to 0. The maximum auto power off time is 99 minutes.

4.7.4. Clear Data Logger Memory

4.7.5. Clear All Data Logger Memory

4.7.6. Copy All Data Logger To micro SD Card

4.7.7. Auto Backup

4.7.8. 94dB Calibration

5. SPL (LXYP) Test Mode

The LCD shows the measurement duration. The longest record is 99 hours 59 minutes 59 seconds.

6. LEQ Test Mode

The LCD shows the measurement period using a countdown system.

6.1. Integral Time Set

In Leq test mode, press [SET] button to enter the integral time setting. You can select from 9 kinds of integral time or set a custom integral time.

Press [SET] button to choose the integral calculus enactment.

Press [◀️] or [▶️] buttons to select the option to adjust.

Press [] or [] buttons to change the digit.

Press [SET] button to save the settings and exit set mode.

7. SEL (LAE) Test Mode

The LCD shows the measurement duration. The longest record is 99 hours 59 minutes 59 seconds.

8. Peak Maximum Test Mode

The LCD shows the measurement duration. The longest record is 99 hours 59 minutes 59 seconds.

9. RT60 (Reverberation Time) Test Mode

The MAX value is the first value obtained that is equal to or greater than 90dB. The MIN value is the MAX value minus 60 dB. The reverberation time is calculated from the MAX value to the MIN value.

9.1. RT 60 Estimate Mode

The RT 60 estimate formula is RT60 = (0.161 × V) / SA.

10. Explanation

10.1. Measurement Parameters:

Test Function Screen parameter Explanation
SPL LAFp Sound pressure level (SPL)
SPL LASp Sound pressure level (SPL)
SPL LCFp Sound pressure level (SPL)
SPL LCSp Sound pressure level (SPL)
SPL LZFp Sound pressure level (SPL)
SPL LZSp Sound pressure level (SPL)
Leq LAFq Equivalent continuous level for the duration of the measurement for A weighting
Leq LCFq Equivalent continuous level for the duration of the measurement for C weighting
Leq LZFq Equivalent continuous level for the duration of the measurement for Z weighting
SEL LAE Frequency weighted sound exposure level for the duration of the measurement for A weighting
SEL LCE Frequency weighted sound exposure level for the duration of the measurement for C weighting
SEL LZE Frequency weighted sound exposure level for the duration of the measurement for A weighting
Peak Lcpeak Instantaneous C peak level

10.2. A, C, Z Weighting Instruction:

10.2.1. Input Interface

The front features a PLT 4 signal input receptacle. Pin definitions are shown in Fig 2:

ST-107:

ST-107S:

10.2.2. Analog AC/DC Output

(Refer to Fig 3 for output receptacle and Fig 4 for 3.5mm output plug)

10.3. The Microphone Lengthens The Test

To avoid measurement deviation caused by reflection effects and operational issues, use the extension cable to lengthen the microphone. (Refer to chapter 11.3.2).

  1. Press [OFF] button to turn the power off.
  2. Separate the preamplifier and microphone from the main body by turning counterclockwise (Refer to Fig 5).
  3. Connect the extension cable to the microphone and main body (Refer to Fig 6).

11. Software Installation

  1. Visit the website: https://www.tenmars.com/
  2. Search for ST-107.
  3. Click on the ST-107 photo.
  4. Click "File Download", then select "Software Download".
  5. Download and unzip the software.
  6. For the latest software information and installation procedures, refer to the software installation guide.

12. Maintenance

12.1. General Information

This is a precision instrument. To ensure its performance, use and store it under suitable environmental conditions. Avoid exposure to high temperatures, humidity, or direct sunlight. Turn off the instrument after use. If you do not expect to use the instrument for a long period, remove the batteries to prevent leakage that could damage internal components.

12.2. Battery Replacement

When the low battery indicator is displayed, the batteries need to be replaced.

  1. Turn off the instrument.
  2. Remove the battery cover.
  3. Remove all batteries from the battery holder.
  4. Insert four new batteries of the same type, observing the polarity signs.
  5. Install the battery cover.

Dispose of waste batteries according to local laws and regulations.

(Fig 1: Opening and closing of battery cover)

12.3. Cleaning

Use a soft, dry cloth to clean the instrument. Never use a wet cloth, solvents, or water.

12.4. End of Life

Caution: This symbol indicates that the equipment and its accessories must be collected and disposed of separately and correctly.

13. Technical Specifications

13.1. Feature

13.2. Environment

13.2.1. Environmental Conditions
13.2.2. EMC

This instrument was designed in accordance with current EMC Standards and its compatibility has been tested according to EN61326-2 (2006).

13.3. Accessories

13.3.1. Standard Accessories

14. Service

14.1. Warranty Conditions

This instrument is guaranteed for one year against material or production defects, in accordance with general sales conditions. During the warranty period, the manufacturer reserves the right to decide whether to repair or replace the product. If the instrument needs to be returned for repair or replacement, make prior arrangements with the local distributor. Include a report describing the reason for return (detected fault). Use original packaging. Any damage incurred during transit due to non-original packaging will be charged to the customer.

The warranty does not apply to:

The contents of this manual may not be reproduced in any form without the manufacturer's authorization. Products are patented, and logotypes are registered. Tenmars reserves the right to modify characteristics and prices as part of technological developments.

14.2. Service

If the instrument is not working properly, before contacting your distributor, ensure that the batteries are correctly installed and working. Check the test leads and replace them if necessary.

Models: ST-107, ST-107S, ST-107 Integrating Sound Level Meter, Integrating Sound Level Meter, Sound Level Meter, Level Meter, Meter

File Info : application/pdf, 28 Pages, 953.01KB

PDF preview unavailable. Download the PDF instead.

HB2ST1070005 英文說明書 A5 (ST-107-107S共用)(無CD) V2

References

HB2ST1070005 英文說明書 A5 (ST-107-107S共用)(無CD) V2 Gaaiho PDF

Related Documents

Preview TENMARS TM-201 Light Meter Specification Sheet
Detailed specifications for the TENMARS TM-201 digital light meter, including measurement range, features like data hold and max hold, accuracy, and sensor type. Suitable for professional light level measurements.
Preview TENMARS Lux/Fc Light Meter User Manual - Models TM-201, TM-202, TM-204, TM-205, TM-205N
User manual for TENMARS Lux/Fc Light Meters (TM-201, TM-202, TM-204, TM-205, TM-205N). This document provides detailed information on the product's description, safety precautions, features, specifications, operation procedures, instrument description, relative spectral sensitivity, attention points, recommended illumination levels, and battery replacement.
Preview Tenmars TM-197 AC/DC Magnetic Field Meter User Manual
Comprehensive user manual for the Tenmars TM-197 AC/DC Magnetic Field Meter, detailing its features, operation, specifications, and maintenance. Covers measurement of magnetic fields, peak hold, data logging, and setup procedures.
Preview Tenmars YF-1002 Digital Multimeter User Manual
User manual for the Tenmars YF-1002 Digital Multimeter, providing detailed information on safety, specifications, operation, maintenance, and accessories.
Preview Tenmars TM-306U Temperature Datalogger User Manual
This user manual provides comprehensive instructions for the Tenmars TM-306U Temperature Datalogger. It covers features, specifications, applications, setup, operation, data recording, PC software usage, connection status, setup screen configuration, time synchronization, data download, graphic analysis, data listing, export options, printing reports, and erasing data. Learn how to effectively use this IP 54 water-proof USB datalogger for temperature monitoring.
Preview Autoranging True RMS Multimeter TM-87 / TM-88 User's Manual
This user manual provides comprehensive instructions for the Tenmars TM-87 and TM-88 Autoranging True RMS Multimeters, covering safety precautions, general description, operating instructions, maintenance, and technical specifications.
Preview Tenmars TM-311N & TM-321N K Type Thermometer User's Guide
User's guide for Tenmars TM-311N Single K Type Thermometer and TM-321N Dual K Type Thermometer, detailing specifications, operation, and features.