Accessories

General Specifications

SpecificationDetails
LCD display digits4 digit LCD display, the largest display 9999.
Polarity indicatorNo indicator in positive, negative indicator " - "
Overload indicatorPositive overload show "OL", negative overload show "-OL"
Low power indicatorWhen [battery-low] display indicator the battery power is low.
Power9V NEAD1604, IEC6F22, JIS006P x1pc
Battery lifeApproximately 100 hours / alkaline battery
Operating temperature0°C~50°C (32°F ~ 122°F), < 80% RH
Storage temperature-10°C ~ 60°C (-4°F ~ 140°F), < 70% RH
WeightApproximately 180g (include batteries)

Electrical Specifications

ParameterValue
Measurement range-200°C to +1372°C (-328°F to +2501°F)
Resolution0.1 (≤999.9)
1 (≥1000)
Reading update1 times/sec
Accuracy (23°C±5°C) (73.4°F±9°F)±0.1% reading + 0.5°C (1°F)
Below -100°C (-148°F): ±(0.2% rdg+ 1°C(2°F))
Temperature coefficient-100°C~+1372°C(-148°F to +2501°F):
0.01% reading +0.05°C /°C (0.1°F /°F) outside the specified +18°C to 28°C (+64°F to +82°F)
Below -100°C (-148°F):
0.02% rdg+0.1°C/°C (0.2°F/ °F)
Temperature ScaleITS-90
Accuracy NoteAccuracy is specified for ambient temperatures between 18~28°C (64~82 °F). The above specifications do not include error of thermocouple.

Operation

  1. ▶️ : Power key.
  2. ?️ : Temperature unit selection key.
  3. [MAX/MIN/AVG] : Memory and inquiry (MAX/MIN/AVG) value of the function key, every press inquiry (MAX/MIN/AVG), press and hold 2 seconds leave function.
  4. [REL] : Relative value function key. (Only for TM-311N)
  5. T1 / T2 : T1, T2 Input channel switching. (only for TM-321N)
  6. [HOLD] : Hold the LCD display function key.
  7. Disable APO: Press and hold the [HOLD] key for 2 seconds, disable or enable Auto Power Off function.
  8. 0°CAdj: Press the [HOLD] key and the ?️ key to enter the digital 0°C adjust settings. Press the [HOLD] key or Press the [MAX/MIN/AVG] key to adjust the bottom window plus or minus 0.1, press the ▶️ key to complete the 0°Cadjust.

Introduction

This product is a portable microcontroller design, offering high measurement accuracy and high stability. It features rugged, easy one-hand operation, digital 0°C adjustment, and the ability to display reading and (maximum / minimum / average) values simultaneously.

Models: TM-321N, TM-311N, TM-311N Single K Type Thermometer, TM-321N Dual K Type Thermometer, K Type Thermometer, Single K Type Thermometer, Thermometer

File Info : application/pdf, 1 Pages, 151.54KB

PDF preview unavailable. Download the PDF instead.

TM-321n

References

GPL Ghostscript 9.52

Related Documents

PreviewTENMARS Lux/Fc Light Meter User Manual - Models TM-201, TM-202, TM-204, TM-205, TM-205N
User manual for TENMARS Lux/Fc Light Meters (TM-201, TM-202, TM-204, TM-205, TM-205N). This document provides detailed information on the product's description, safety precautions, features, specifications, operation procedures, instrument description, relative spectral sensitivity, attention points, recommended illumination levels, and battery replacement.
PreviewAutoranging True RMS Multimeter TM-87 / TM-88 User's Manual
This user manual provides comprehensive instructions for the Tenmars TM-87 and TM-88 Autoranging True RMS Multimeters, covering safety precautions, general description, operating instructions, maintenance, and technical specifications.
PreviewTENMARS TM-201 Light Meter Specification Sheet
Detailed specifications for the TENMARS TM-201 digital light meter, including measurement range, features like data hold and max hold, accuracy, and sensor type. Suitable for professional light level measurements.
PreviewTenmars TM-306U Temperature Datalogger User Manual
This user manual provides comprehensive instructions for the Tenmars TM-306U Temperature Datalogger. It covers features, specifications, applications, setup, operation, data recording, PC software usage, connection status, setup screen configuration, time synchronization, data download, graphic analysis, data listing, export options, printing reports, and erasing data. Learn how to effectively use this IP 54 water-proof USB datalogger for temperature monitoring.
PreviewTenmars TM-197 AC/DC Magnetic Field Meter User Manual
Comprehensive user manual for the Tenmars TM-197 AC/DC Magnetic Field Meter, detailing its features, operation, specifications, and maintenance. Covers measurement of magnetic fields, peak hold, data logging, and setup procedures.
PreviewTenmars YF-1002 Digital Multimeter User Manual
User manual for the Tenmars YF-1002 Digital Multimeter, providing detailed information on safety, specifications, operation, maintenance, and accessories.
PreviewTenmars ST-107/ST-107S Integrating Sound Level Meter User's Manual
User's manual for the Tenmars ST-107 and ST-107S Integrating Sound Level Meters, covering instrument description, preparation, measurement procedures, maintenance, technical specifications, and service information.