User Guide for SCHLAGE models including: CO-100 Offline Locks
2 Schlage CO-100 user guide ... Manual programming instructions .
When ready to set up for normal use, enter a new programming code, then program the user credentials. See Manual programming instructions on page 5. 4 .
File Info : application/pdf, 16 Pages, 7.32MB
DocumentDocument*P516-270* P516-270 CO-100 Offline lock user guide Instructions for CO-Series offline locks Para el idioma español, navegue hacia us.allegion.com. Pour la portion française, veuillez consulter le site us.allegion.com. Contents Overview ........................................................................................................................... 3 Lock functions...................................................................................................................4 Getting started ..................................................................................................................4 Construction access mode ...............................................................................................4 Credential types and functions .........................................................................................5 Manual programming instructions.....................................................................................5 Important notes: ............................................................................................................ 5 PROGRAMMING credential..........................................................................................5 NORMAL USE credentials ............................................................................................6 TOGGLE credentials.....................................................................................................6 FREEZE credentials......................................................................................................6 PASS THROUGH credentials .......................................................................................6 OTHER programming ...................................................................................................7 Error codes ......................................................................................................................8 Test lock operation............................................................................................................8 Mechanical test ............................................................................................................. 8 Electronic test................................................................................................................8 Normal lock operation.......................................................................................................8 Wired remote release feature ...........................................................................................9 System requirements .................................................................................................... 9 Switch specifications, wire specifications and routing...................................................9 Wired remote release operation....................................................................................9 Wired remote release button action .............................................................................. 9 Lock status reports .........................................................................................................10 Reset to factory defaults ................................................................................................. 11 Batteries .........................................................................................................................12 To install or replace alkaline batteries .........................................................................12 Low battery indications................................................................................................12 Battery failure mode ....................................................................................................13 LED reference.................................................................................................................13 Schlage button ............................................................................................................ 13 Optional Inside Push Button (IPB) ..............................................................................13 Troubleshooting .............................................................................................................. 14 FCC Statements .............................................................................................................15 This product is compliant of UL 294 and ULC -S319 standard. This product's compliance would be invalidated through the use of any add-on, expansion, memory or other module that has not yet been evaluated for compatibility for use with this UL Listed product, in accordance with the requirements of the Standards UL 294 and ULC -S319. This product has been evaluated for ULC-S319 Class I. UL294 Access Control Levels tested to: Destructive Attack - Level 1; Line Security - Level 1; Endurance - Level 4; Standby Power - Level 1. 2 · Schlage · CO-100 user guide Overview The Schlage CO-100 is a keypad-only off-line electronic lock in the CO-Series product line. · This product is listed for UL 294 and ULC -S319. · Three factory-configured functions are available: 1) Classroom/Storeroom, 2) Office, and 3) Privacy. · The lock is powered by four (4) AA batteries. See Batteries on page 12 for more information. · Outside lever is normally locked. · Inside lever always allows egress. Outside Schlage Button Keypad Outside Lever Keyway Inside Battery Compartment Optional Inside Push Button Inside Lever CO-100-CY CO-100-MS CO-100-993 3 · Schlage · CO-100 user guide Lock functions The CO-100 lock is available in one of three functions: Privacy (40): Privacy function is available on locks with firmware version 2.6.2 or higher. Lockset is normally secure. Inside Push Button is pressed to disable normal electronic access from outside (activates privacy). Another press of Inside Push Button restores normal electronic access (deactivates privacy). Office (50): Lockset is normally secure. Inside Push Button may be used to select passage or secured status. Classroom/Storeroom (70): Lockset is normally secure. Valid toggle credentials may be used to change to a passage or secure status. Getting started Follow these steps when setting up a new lock. 1. Install the lock. See the installation guide that came with the lock or visit us.allegion.com for more information. 2. Test the lock for proper mechanical and electronic operation. See Test lock operation on page 8 for more information. 3. When ready to set up for normal use, enter a new programming code, then program the user credentials. See Manual programming instructions on page 5. 4. Familiarize yourself with the information in this guide. Save this user guide for future reference. Construction access mode Construction access mode is used to allow access before the lock has been programmed, and for testing purposes. Construction access mode is enabled by default. Offline locks with keypads have a default PIN of 13579 and " # ", which can be used for installation, testing and construction access. · To test, enter the default PIN (13579 and " # "). · The Schlage button will blink and the lock will unlock. · The default PIN is automatically deleted when a new programming credential is created. TIP If you press the default PIN code on a new lock and the code is not accepted, the lock has already been programmed. If the new PIN is not known, or to put the lock back into construction access mode, reset the lock to factory settings. See Reset to factory defaults on page 11 for more information. 4 · Schlage · CO-100 user guide Credential types and functions Programming credential: A 5 digit code used only for lock programming. PIN credential: A 3-6 digit code entered on the keypad. Note: A unique credential must be used for each credential type described below (for example, a single credential may not be used for both normal use and toggle functions). Credential type Function Programming PIN Used only to program the lock. Does not unlock the lock. Normal use PIN Toggle PIN Freeze PIN Pass-through PIN Unlocks the lock momentarily after a credential is entered. Changes the state of the lock from locked (secured) to unlocked (unsecured), or vice versa, unless in a Freeze state. Freezes the lock in the current state. The lock remains frozen until any Freeze credential is entered again. (A pass-through credential will override a lock in frozen state as described below). Unlocks a lock momentarily, regardless of state. A valid Pass-through credential can unlock a door set to any secured lockout mode (e.g., Freeze, Privacy, Time Zones, Door Auto-Locks and Holidays). The door will relock after the specified relock time. Manual programming instructions Important notes: L Wait for the Schlage button LEDs to stop flashing before continuing to the next step. L Programming mode will time out if no entry is made in 20-25 seconds. Time out is indicated by three left and nine right red blinks of the Schlage button. L An incorrect entry is indicated by a solid red left and blinking green right LED on the Schlage button. Refer to Error codes on page 8 to interpret error code patterns. L A unique PIN must be used for each credential type (for example, a single PIN may not be used for both normal use and toggle functions). PROGRAMMING credential To complete this action: Wait for Perform the following steps: to stop flashing between each step! Create new Programming Code (PIN) 1 Enter (This is the default programming PIN) 2 Enter 3 4 Enter new 5 digit Reenter the new 5 Programming digit Programming code and Wait for right green light. code and Wait for confirmation: 2 right green blinks. Note: Programming codes such as 1-1-1-1-1 or 1-2-3-4-5 can be easily selected by non-authorized users and should not be used. 5 · Schlage · CO-100 user guide NORMAL USE credentials Note: Until a new Normal Use PIN is created, the default PIN is To complete this action: Wait for Perform the following steps: to stop flashing between each step! 1 2 3 4 5 6 Create a Enter Normal Use Programming PIN PIN and Enter Enter new For another 3-6 digit PIN, go PIN and back to step 3 Press again to finish Wait for confirmation: 2 right green blinks. TOGGLE credentials To complete this action: Wait for Perform the following steps: to stop flashing between each step! 1 2 3 4 5 6 Create a Toggle PIN Enter Programming PIN and Enter Enter Enter new 3-6 digit PIN and For another PIN, go back to step 4 Wait for confirmation: 2 right green blinks. Wait for right green light. OR press again to finish FREEZE credentials To complete this action: Wait for Perform the following steps: to stop flashing between each step! 1 2 3 4 5 6 Create a Freeze PIN Enter Programming PIN and Enter Enter Enter new 3-6 digit PIN and For another PIN, go back to step 4 OR Wait for confirmation: 2 right green blinks. Wait for right green light. press again to finish PASS THROUGH credentials To complete Perform the following steps: this action: Wait for to stop flashing between each step! 1 2 3 4 5 6 Create a Pass Through PIN Enter Programming PIN and Enter Enter Enter new 3-6 digit PIN and For another PIN, go back to step 4 OR Wait for confirmation: 2 right green blinks. Wait for right green light. press again to finish 6 · Schlage · CO-100 user guide OTHER programming To complete this action: Wait for Perform the following steps: to stop flashing between each step! 1 2 3 4 5 Delete a PIN Enter Programming PIN and Enter Enter the PIN to be deleted and To delete another PIN, go back to step 3 OR press again to finish Wait for confirmation: 2 right green blinks. Change PIN Enter length Programming (Available PIN and with firmware version 2.5.0 or higher.) Enter Enter Enter , , , OR for desired PIN length Press again to finish Wait for confirmation: 2 right green blinks. Change Enter relock delay Programming period PIN and Enter Enter Each button press adds to the total delay time Example: + adds a 10 second delay Press again to finish Wait for confirmation: 2 right green blinks. Disable/ enable beeper Enter Programming PIN and Enter Enter Enter to disable beeper OR to enable beeper Press again to finish Wait for confirmation: 2 right green blinks. Disable/ enable remote release feature Enter Programming PIN and Enter Enter Enter to disable remote release OR to enable remote release Press again to finish Wait for confirmation: 2 right green blinks. Disable/ enable occupancy indicator feature Enter Programming PIN and Enter Enter Enter to disable occupancy indicator blinks OR to enable occupancy indicator fast blinks OR Press again to finish Wait for confirmation: 2 right green blinks. to enable occupancy indicator slow blinks 7 · Schlage · CO-100 user guide Error codes L All error codes are indicated on the Schlage button by a solid red left LED, and a blinking green right LED. The number of green blinks indicates the error code. Red Green Left LED Right LED Number of green blinks Error code description Too long programming/user code entered. 2 Programming code must be five (5) digits. User code length cannot exceed six (6) digits. 3 Memory full, too many codes. Delete some codes. 4 Programming code cannot be deleted, only changed. 5 Programming code entries do not match. Programming code not changed. 6 Invalid command. Invalid function code entered. 7 Code not found. Error code functions have not been verified by Underwriters Code too short. Programming code length must be Laboratories Inc. 8 five (5) digits. User code minimum length is three (3) digits. 9 Not a unique code. Test lock operation If you encounter problems while performing any of the following tests, review the installation guide and correct any problems. Mechanical test 1. Rotate the inside lever or depress the push bar to open the door. Operation should be smooth, and the latch should retract. 2. Insert the key into the keyway and rotate the key and the outside lever to open the door. Operation should be smooth, and the latch should retract. Electronic test 1. Press any number key. The lock will beep. Use the default PIN (13579 and "#") to verify access. Normal lock operation After PIN credentials have been programmed, enter a PIN to operate the lock: Press a valid PIN. The green LED will blink and access is granted. The "#" key is used as ENTER key for PINs with fewer than six digits. Default minimum digits is six (6). PIN length may be manually configured so users do not have to push the "#" key (see Change PIN length on page 7). If the PIN credential is entered incorrectly, press "*" to start over. 8 · Schlage · CO-100 user guide Wired remote release feature System requirements · Available on CO-100 Office function only. · The CO-100 must be programmed with CO-100 version 2.6.2 firmware or higher. Switch specifications, wire specifications and routing · Recommended switch: basic SPST (single-pole single-throw) momentary action switch with normally open contact configuration. · Wire gauge AWG 24, stranded, twisted pair, shielded. (Shielded cable is optional. If shield is present, only one end of the cable shield should be terminated to chassis ground). · Belden 9841 or equivalent. · Maximum cable length is 1000 feet (305 meters). · Route wires from the switch, through the door frame and door to the door position switch terminals as shown below. Attach switch wires to DPS terminals Wired remote release operation · When the remote release button is pressed the lock will unlock for the programmed relock delay period. The green Schlage LEDs and the green inside push button LED will turn on to indicate the lock is unlocked. If the beeper function is turned on, the beeper will sound one time to indicate the lock is unlocked. · After the relock delay period has expired, the green Schlage LEDs and the green inside push button LED will turn off. If the beeper function is turned on, the beeper will sound two times to indicate the lock is relocked. Wired remote release button action · If the remote release button is pressed and held, the release will function only one time, even in the event the button is held longer than the relock delay period. · If the remote release button is quickly pressed repeatedly, the release will function only one time. Any additional button presses during the relock delay period are ignored. · Once the lock relocks, the next press of the remote release button will activate a new release cycle. 9 · Schlage · CO-100 user guide Lock status reports Follow the steps below to obtain lock status reports: L Lock status reporting is available with firmware version 2.5.0 or higher. L The left and right Schlage button LEDs will blink red once with each button press, followed by the status indicator as described below. Function / Report Initiate report mode Press Press and hold while pressing Battery status Indicator/Report result Wait until only the right Schlage button LED is on to indicate the lock is in report mode and awaiting an entry. If no entry is made, then timeout will occur in 20 seconds. Left LED: Solid green = normal Blinking red = low No indicator = critical battery Once a status is reported, both left and right LEDs will light green, followed by solid green on the right LED only. The right green LED indicates the lock is awaiting another entry. Obtain an additional status report as described below, or press mode. to exit report Function / Report Firmware status Hardware status PCB serial number Press Indicator/Report result Left LED blinks green for the version number Decimal point is indicated by one red blink "Zero" is indicated by two red blinks Left LED blinks green for each number Each number is separated by one red blink Press after two red blinks to display the next number If no entry is made within 20 seconds of the solid green right LED, then timeout will occur. To exit report mode at any time, press . 10 · Schlage · CO-100 user guide Reset to factory defaults All information in the main controller in the lock will be deleted and reset to factory defaults! Main controller configurations that will reset to factory default include: programming and user codes. The door must be locked (not toggled open or in the middle of normal access) before resetting to factory defaults. Follow these steps to reset to factory defaults. 1. Remove the top inside cover. 2. Remove one battery from the battery pack to disrupt power. Wait 5 to 10 seconds for power to run out in the lock. 3. Press and hold the Schlage button while reconnecting the battery into the battery pack to resupply power. 4. Continue holding the Schlage button, and wait for two beeps to sound and two green blinks of the Schlage button. 5. Release the Schlage button. 6. Press and release the Schlage button three (3) times within 10 seconds of the beeps and blinks at step 4. One beep will sound and one red blink will occur with each press. 7. The Schlage button will light green for one second and a one-second beep will sound, indicating that the lock has been reset. L If the Schlage button is not pressed 3 times within 10 seconds, two beeps and two red blinks indicate timeout. 8. Replace the top inside cover. To test, enter 13579 and "#". The Schlage button will blink and the lock will unlock momentarily. 11 · Schlage · CO-100 user guide Batteries To install or replace alkaline batteries L Changing batteries does not affect any programmed data. 1. Remove the battery cover. 2. Remove the battery bracket. Do not allow the battery pack to hang from the wires. 3. Install the new batteries (install only new AA Alkaline batteries). Make sure the batteries are installed in the correct orientation. 4. Reinstall the battery pack and battery bracket. 5. Reinstall the battery cover, making sure the plug is to the right of the battery pack (CY, MS, and MD locks). Be careful not to pinch the battery wires when installing the battery cover. CAUTION! Danger of explosion if batteries are incorrectly replaced! Replace only with new AA alkaline batteries. Dispose of used batteries according to the manufacturer's instructions. This product has been evaluated for ULCS319 compliance with AA batteries listed below. For installations requiring ULCS319, these battery models should be used. Duracell PC1500, MN1500; Energizer E91, EN91, AX91, XR91; RayoVac 815, 815-HE ! Plug MUST Be on Right CY, MS 993 Low battery indications Condition Indicator Batteries low After credential PIN is pressed, 9 red blinks of Schlage button, then normal indicator. Battery No LED or beeps failure Valid credentials do not grant access Solution Replace batteries immediately to avoid battery failure. Lock is intended to operate for 500 cycles in low battery condition. Replace batteries immediately. Mechanical override key must be used to unlock the lock. Battery failure mode In the event of battery failure, the lock will fail As-Is (lock remains in current state, locked or unlocked, until batteries are replaced). 12 · Schlage · CO-100 user guide LED reference Schlage button Condition Lights Access denied 2 red blinks Valid PIN entered while lock in Freeze mode 12 red blinks indicating lockout Factory default reset One-second solid green with one-second beep Low battery indicator, AA batteries 9 left red blinks Momentary unsecured access 1 green blink, then one red blink on relock Occupancy indicator fast blinks are enabled 1 red blink every 1.5 seconds* Occupancy indicator slow blinks are Sequential 1 red blink on both left and right enabled every 1.5 seconds* * The red blinks will turn amber for occupancy indicator when the lock's battery is low. Optional Inside Push Button (IPB) Action Office Mode Press IPB to lock Press IPB to unlock1 Privacy Mode With door closed, press IPB to engage privacy With door closed, press IPB to release privacy Lights 1 red blink 1 green blink 4 green blinks 4 red blinks Condition Occupancy Indicator Feature Occupancy indicator blinks fast mode/slow mode Lights 1 red blink every 3 seconds* 1 Unlocking the lock with the IPB will cause the lock to remain unlocked until the IPB is depressed again. * The red blinks will turn amber for occupancy indicator when the lock's battery is low. 13 · Schlage · CO-100 user guide Troubleshooting Problem Possible cause Solution The lock does The beeper may be Use manual programming to enable the beeper not function turned off. (see Disable/enable beeper on page 7). when a valid PIN credential is entered, or the lock beeper does The battery or wired power may be improperly connected. Check that the battery or wired power is connected correctly. Check that batteries are inserted in the correct not sound. The batteries may be polarity. inserted with incorrect Replace batteries. polarity. Check that the optional IPB through-door ribbon The batteries may be cable is plugged in correctly (if applicable). The depleted. red wire should be on the left and not pinched in If applicable, the IPB the door. through-door ribbon cable may not be properly plugged in, or may have bent pins. Check that there are no bent pins on the optional IPB through-door cable. Refer to the installation instructions that came with the CO-100 lock, or this user guide for details on the above mentioned procedures. Wired remote The lock may not Wired remote release is available only on the release feature is be compatible with CO-100 Office function. not working. remote release. Wired remote release is compatible with locks The firmware programmed with CO-100 version 2.6.2 firmware version may not or higher. be compatible with remote release. Check that the switch closes and delivers less than 5 ohms resistance when activated. The remote release switch may not be functioning correctly. 14 · Schlage · CO-100 user guide FCC Statements This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. this device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. 15 · Schlage · CO-100 user guide Customer Service 1-877-671-7011 www.allegion.com/us © Allegion 2020 Printed in U.S.A. P516-270 Rev. 03/20-L