2 Schlage CO-100 user guide ... Manual programming instructions .

When ready to set up for normal use, enter a new programming code, then program the user credentials. See Manual programming instructions on page 5. 4 .

PDF Schlage CO-100 Series User Guide - English


File Info : application/pdf, 16 Pages, 7.32MB

PDF preview unavailable. Download the PDF instead.

Schlage CO-100 Offline Lock User Guide - English 104210
*P516-270*
P516-270
CO-100
Offline lock user guide Instructions for CO-Series offline locks
Para el idioma español, navegue hacia us.allegion.com. Pour la portion française, veuillez consulter le site us.allegion.com.

Contents
Overview ........................................................................................................................... 3 Lock functions...................................................................................................................4 Getting started ..................................................................................................................4 Construction access mode ...............................................................................................4 Credential types and functions .........................................................................................5 Manual programming instructions.....................................................................................5
Important notes: ............................................................................................................ 5 PROGRAMMING credential..........................................................................................5 NORMAL USE credentials ............................................................................................6 TOGGLE credentials.....................................................................................................6 FREEZE credentials......................................................................................................6 PASS THROUGH credentials .......................................................................................6 OTHER programming ...................................................................................................7 Error codes ......................................................................................................................8 Test lock operation............................................................................................................8 Mechanical test ............................................................................................................. 8 Electronic test................................................................................................................8 Normal lock operation.......................................................................................................8 Wired remote release feature ...........................................................................................9 System requirements .................................................................................................... 9 Switch specifications, wire specifications and routing...................................................9 Wired remote release operation....................................................................................9 Wired remote release button action .............................................................................. 9 Lock status reports .........................................................................................................10 Reset to factory defaults ................................................................................................. 11 Batteries .........................................................................................................................12 To install or replace alkaline batteries .........................................................................12 Low battery indications................................................................................................12 Battery failure mode ....................................................................................................13 LED reference.................................................................................................................13 Schlage button ............................................................................................................ 13 Optional Inside Push Button (IPB) ..............................................................................13 Troubleshooting .............................................................................................................. 14 FCC Statements .............................................................................................................15
This product is compliant of UL 294 and ULC -S319 standard. This product's compliance would be invalidated through the use of any add-on, expansion, memory or other module that has not yet been evaluated for compatibility for use with this UL Listed product, in accordance with the requirements of the Standards UL 294 and ULC -S319. This product has been evaluated for ULC-S319 Class I. UL294 Access Control Levels tested to: Destructive Attack - Level 1; Line Security - Level 1; Endurance - Level 4; Standby Power - Level 1.
2 · Schlage · CO-100 user guide

Overview
The Schlage CO-100 is a keypad-only off-line electronic lock in the CO-Series product line. · This product is listed for UL 294 and ULC -S319. · Three factory-configured functions are available: 1) Classroom/Storeroom, 2) Office, and 3) Privacy. · The lock is powered by four (4) AA batteries. See Batteries on page 12 for more information. · Outside lever is normally locked. · Inside lever always allows egress.
Outside Schlage Button
Keypad

Outside Lever Keyway

Inside

Battery Compartment
Optional Inside Push Button
Inside Lever

CO-100-CY CO-100-MS

CO-100-993
3 · Schlage · CO-100 user guide

Lock functions
The CO-100 lock is available in one of three functions:
Privacy (40): Privacy function is available on locks with firmware version 2.6.2 or higher. Lockset is normally secure. Inside Push Button is pressed to disable normal electronic access from outside (activates privacy). Another press of Inside Push Button restores normal electronic access (deactivates privacy).
Office (50): Lockset is normally secure. Inside Push Button may be used to select passage or secured status.
Classroom/Storeroom (70): Lockset is normally secure. Valid toggle credentials may be used to change to a passage or secure status.

Getting started
Follow these steps when setting up a new lock. 1. Install the lock. See the installation guide that came with the lock or visit us.allegion.com for more information. 2. Test the lock for proper mechanical and electronic operation. See Test lock operation on page 8 for more information. 3. When ready to set up for normal use, enter a new programming code, then program the user credentials. See Manual programming instructions on page 5. 4. Familiarize yourself with the information in this guide.
Save this user guide for future reference.

Construction access mode

Construction access mode is used to allow access before the lock has been programmed, and for testing purposes. Construction access mode is enabled by default.
Offline locks with keypads have a default PIN of 13579 and " # ", which can be used for installation, testing and construction access.
· To test, enter the default PIN (13579 and " # "). · The Schlage button will blink and the lock will
unlock. · The default PIN is automatically deleted when a
new programming credential is created.

TIP
If you press the default PIN code on a new lock and the code is not accepted, the lock has already been programmed.
If the new PIN is not known, or to put the lock back into construction access mode, reset the lock to factory settings. See Reset to factory defaults on page 11 for more information.

4 · Schlage · CO-100 user guide

Credential types and functions

Programming credential: A 5 digit code used only for lock programming. PIN credential: A 3-6 digit code entered on the keypad. Note: A unique credential must be used for each credential type described below (for example, a single credential may not be used for both normal use and toggle functions).

Credential type

Function

Programming PIN Used only to program the lock. Does not unlock the lock.

Normal use PIN Toggle PIN Freeze PIN
Pass-through PIN

Unlocks the lock momentarily after a credential is entered.
Changes the state of the lock from locked (secured) to unlocked (unsecured), or vice versa, unless in a Freeze state. Freezes the lock in the current state. The lock remains frozen until any Freeze credential is entered again. (A pass-through credential will override a lock in frozen state as described below).
Unlocks a lock momentarily, regardless of state.
A valid Pass-through credential can unlock a door set to any secured lockout mode (e.g., Freeze, Privacy, Time Zones, Door Auto-Locks and Holidays). The door will relock after the specified relock time.

Manual programming instructions
Important notes: L Wait for the Schlage button LEDs to stop flashing before continuing to the next step.
L Programming mode will time out if no entry is made in 20-25 seconds. Time out is indicated by three left and nine right red blinks of the Schlage button.
L An incorrect entry is indicated by a solid red left and blinking green right LED on the Schlage button. Refer to Error codes on page 8 to interpret error code patterns.
L A unique PIN must be used for each credential type (for example, a single PIN may not be used for both normal use and toggle functions).

PROGRAMMING credential

To complete this action:

Wait for

Perform the following steps: to stop flashing between each step!

Create new Programming
Code (PIN)

1 Enter
(This is the default programming PIN)

2 Enter

3

4

Enter new 5 digit Reenter the new 5 Programming digit Programming

code and Wait for right green light.

code and Wait for confirmation: 2 right green blinks.

Note: Programming codes such as 1-1-1-1-1 or 1-2-3-4-5 can be easily selected by non-authorized users and should not be used.

5 · Schlage · CO-100 user guide

NORMAL USE credentials

Note: Until a new Normal Use PIN is created, the default PIN is

To complete this action:

Wait for

Perform the following steps: to stop flashing between each step!

1

2

3

4

5

6

Create a

Enter

Normal Use Programming

PIN

PIN and

Enter

Enter new For another 3-6 digit PIN, go PIN and back to
step 3

Press
again to finish

Wait for confirmation: 2 right green
blinks.

TOGGLE credentials

To complete this action:

Wait for

Perform the following steps: to stop flashing between each step!

1

2

3

4

5

6

Create a Toggle
PIN

Enter Programming
PIN and

Enter

Enter

Enter new 3-6 digit PIN and

For another PIN, go back to step 4

Wait for confirmation: 2 right green
blinks.

Wait for right green
light.

OR
press again to
finish

FREEZE credentials

To complete this action:

Wait for

Perform the following steps: to stop flashing between each step!

1

2

3

4

5

6

Create a Freeze
PIN

Enter Programming
PIN and

Enter

Enter

Enter new 3-6 digit PIN and

For another PIN, go back
to step 4 OR

Wait for confirmation: 2 right green
blinks.

Wait for right green
light.

press again to
finish

PASS THROUGH credentials

To complete

Perform the following steps:

this action:

Wait for

to stop flashing between each step!

1

2

3

4

5

6

Create a Pass
Through PIN

Enter Programming
PIN and

Enter

Enter

Enter new 3-6 digit PIN and

For another PIN, go back
to step 4 OR

Wait for confirmation: 2 right green
blinks.

Wait for right green
light.

press again to
finish

6 · Schlage · CO-100 user guide

OTHER programming

To complete this action:

Wait for

Perform the following steps: to stop flashing between each step!

1

2

3

4

5

Delete a PIN Enter Programming
PIN and

Enter

Enter the PIN to be deleted
and

To delete another PIN, go back to step 3
OR press again to finish

Wait for confirmation: 2 right green
blinks.

Change PIN

Enter

length Programming

(Available

PIN and

with firmware

version 2.5.0

or higher.)

Enter

Enter

Enter
, , , OR for desired PIN
length

Press
again to finish Wait for confirmation: 2 right green blinks.

Change

Enter

relock delay Programming

period

PIN and

Enter

Enter

Each button press adds to the total delay
time Example: + adds a 10 second delay

Press again to finish Wait for confirmation: 2 right green blinks.

Disable/ enable beeper

Enter Programming
PIN and

Enter

Enter

Enter to disable
beeper OR
to enable beeper

Press again to finish Wait for confirmation: 2 right green blinks.

Disable/ enable remote release feature

Enter Programming
PIN and

Enter

Enter

Enter to disable remote release
OR
to enable remote release

Press again to finish Wait for confirmation: 2 right green blinks.

Disable/ enable occupancy indicator feature

Enter Programming
PIN and

Enter

Enter

Enter to disable occupancy indicator blinks
OR
to enable occupancy indicator fast
blinks OR

Press again to finish Wait for confirmation: 2 right green blinks.

to enable occupancy indicator slow
blinks

7 · Schlage · CO-100 user guide

Error codes

L All error codes are indicated on the Schlage button by a solid red left LED, and a blinking green right LED. The number of green blinks indicates the error code.

Red

Green

Left LED Right LED

Number of green blinks

Error code description

Too long programming/user code entered.

2

Programming code must be five (5) digits. User code

length cannot exceed six (6) digits.

3

Memory full, too many codes. Delete some codes.

4

Programming code cannot be deleted, only changed.

5

Programming code entries do not match. Programming code not changed.

6

Invalid command. Invalid function code entered.

7

Code not found.

Error code functions have not been verified by Underwriters

Code too short. Programming code length must be

Laboratories Inc.

8

five (5) digits. User code minimum length is three (3)

digits.

9

Not a unique code.

Test lock operation
If you encounter problems while performing any of the following tests, review the installation guide and correct any problems.
Mechanical test 1. Rotate the inside lever or depress the push bar to open the door. Operation should be
smooth, and the latch should retract. 2. Insert the key into the keyway and rotate the key and the outside lever to open the door.
Operation should be smooth, and the latch should retract.
Electronic test 1. Press any number key. The lock will beep. Use the default PIN (13579 and "#") to verify
access.

Normal lock operation
After PIN credentials have been programmed, enter a PIN to operate the lock: Press a valid PIN. The green LED will blink and access is granted.
The "#" key is used as ENTER key for PINs with fewer than six digits. Default minimum digits is six (6). PIN length may be manually configured so users do not have to push the "#" key (see Change PIN length on page 7).
If the PIN credential is entered incorrectly, press "*" to start over.

8 · Schlage · CO-100 user guide

Wired remote release feature
System requirements · Available on CO-100 Office function only. · The CO-100 must be programmed with CO-100 version 2.6.2 firmware or higher.
Switch specifications, wire specifications and routing · Recommended switch: basic SPST (single-pole single-throw) momentary action switch
with normally open contact configuration. · Wire gauge AWG 24, stranded, twisted pair, shielded. (Shielded cable is optional.
If shield is present, only one end of the cable shield should be terminated to chassis ground). · Belden 9841 or equivalent. · Maximum cable length is 1000 feet (305 meters). · Route wires from the switch, through the door frame and door to the door position switch terminals as shown below.
Attach switch wires to DPS
terminals
Wired remote release operation · When the remote release button is pressed the lock will unlock for the programmed
relock delay period. The green Schlage LEDs and the green inside push button LED will turn on to indicate the lock is unlocked. If the beeper function is turned on, the beeper will sound one time to indicate the lock is unlocked. · After the relock delay period has expired, the green Schlage LEDs and the green inside push button LED will turn off. If the beeper function is turned on, the beeper will sound two times to indicate the lock is relocked.
Wired remote release button action · If the remote release button is pressed and held, the release will function only one time,
even in the event the button is held longer than the relock delay period. · If the remote release button is quickly pressed repeatedly, the release will function only
one time. Any additional button presses during the relock delay period are ignored. · Once the lock relocks, the next press of the remote release button will activate a new
release cycle.
9 · Schlage · CO-100 user guide

Lock status reports

Follow the steps below to obtain lock status reports:
L Lock status reporting is available with firmware version 2.5.0 or higher.
L The left and right Schlage button LEDs will blink red once with each button press, followed by the status indicator as described below.

Function / Report
Initiate report mode

Press Press and hold
while pressing

Battery status

Indicator/Report result
Wait until only the right Schlage button LED is on to indicate the lock is in report mode and awaiting an entry. If no entry is made, then timeout will occur in 20 seconds.
Left LED:
Solid green = normal Blinking red = low No indicator = critical battery

Once a status is reported, both left and right LEDs will light green, followed by solid green on the right LED only. The right green LED indicates the lock is awaiting another entry.

Obtain an additional status report as described below, or press mode.

to exit report

Function / Report
Firmware status Hardware status
PCB serial number

Press

Indicator/Report result Left LED blinks green for the version number Decimal point is indicated by one red blink "Zero" is indicated by two red blinks Left LED blinks green for each number Each number is separated by one red blink
Press after two red blinks to display the next number

If no entry is made within 20 seconds of the solid green right LED, then timeout will occur.

To exit report mode at any time, press .

10 · Schlage · CO-100 user guide

Reset to factory defaults
All information in the main controller in the lock will be deleted and reset to factory defaults! Main controller configurations that will reset to factory default include: programming and user codes. The door must be locked (not toggled open or in the middle of normal access) before resetting to factory defaults. Follow these steps to reset to factory defaults. 1. Remove the top inside cover. 2. Remove one battery from the battery pack to disrupt power. Wait 5 to 10 seconds for
power to run out in the lock. 3. Press and hold the Schlage button while reconnecting the battery into the battery pack
to resupply power. 4. Continue holding the Schlage button, and wait for two beeps to sound and two green
blinks of the Schlage button. 5. Release the Schlage button. 6. Press and release the Schlage button three (3) times within 10 seconds of the beeps
and blinks at step 4. One beep will sound and one red blink will occur with each press. 7. The Schlage button will light green for one second and a one-second beep will sound,
indicating that the lock has been reset. L If the Schlage button is not pressed 3 times within 10 seconds, two beeps and two
red blinks indicate timeout. 8. Replace the top inside cover. To test, enter 13579 and "#". The Schlage button will blink and the lock will unlock momentarily.
11 · Schlage · CO-100 user guide

Batteries
To install or replace alkaline batteries L Changing batteries does not affect any programmed data. 1. Remove the battery cover. 2. Remove the battery bracket. Do not allow the battery pack to hang from the wires. 3. Install the new batteries (install only new AA Alkaline batteries). Make sure the batteries
are installed in the correct orientation. 4. Reinstall the battery pack and battery bracket. 5. Reinstall the battery cover, making sure the plug is to the right of the battery pack (CY,
MS, and MD locks). Be careful not to pinch the battery wires when installing the battery cover.
CAUTION! Danger of explosion if batteries are incorrectly replaced! Replace only with new AA alkaline batteries. Dispose of used batteries according to the manufacturer's instructions.
This product has been evaluated for ULCS319 compliance with AA batteries listed below. For installations requiring ULCS319, these battery models should be used.
Duracell PC1500, MN1500; Energizer E91, EN91, AX91, XR91; RayoVac 815, 815-HE
! Plug MUST Be on Right

CY, MS

993

Low battery indications

Condition

Indicator

Batteries low After credential PIN is pressed,

9 red blinks of Schlage button,

then normal indicator.

Battery

No LED or beeps

failure

Valid credentials do not grant

access

Solution
Replace batteries immediately to avoid battery failure. Lock is intended to operate for 500 cycles in low battery condition. Replace batteries immediately. Mechanical override key must be used to unlock the lock.

Battery failure mode
In the event of battery failure, the lock will fail As-Is (lock remains in current state, locked or unlocked, until batteries are replaced).

12 · Schlage · CO-100 user guide

LED reference

Schlage button

Condition

Lights

Access denied

2 red blinks

Valid PIN entered while lock in Freeze mode 12 red blinks indicating lockout

Factory default reset

One-second solid green with one-second beep

Low battery indicator, AA batteries

9 left red blinks

Momentary unsecured access

1 green blink, then one red blink on relock

Occupancy indicator fast blinks are enabled 1 red blink every 1.5 seconds*

Occupancy indicator slow blinks are

Sequential 1 red blink on both left and right

enabled

every 1.5 seconds*

* The red blinks will turn amber for occupancy indicator when the lock's battery is low.

Optional Inside Push Button (IPB)

Action
Office Mode Press IPB to lock Press IPB to unlock1 Privacy Mode With door closed, press IPB to engage privacy With door closed, press IPB to release privacy

Lights
1 red blink 1 green blink
4 green blinks 4 red blinks

Condition Occupancy Indicator Feature Occupancy indicator blinks fast mode/slow mode

Lights 1 red blink every 3 seconds*

1 Unlocking the lock with the IPB will cause the lock to remain unlocked until the IPB is depressed again.

* The red blinks will turn amber for occupancy indicator when the lock's battery is low.

13 · Schlage · CO-100 user guide

Troubleshooting

Problem

Possible cause

Solution

The lock does The beeper may be Use manual programming to enable the beeper

not function

turned off.

(see Disable/enable beeper on page 7).

when a valid PIN credential is entered, or the lock beeper does

The battery or wired power may be improperly connected.

Check that the battery or wired power is connected correctly.
Check that batteries are inserted in the correct

not sound.

The batteries may be polarity.

inserted with incorrect Replace batteries.

polarity.

Check that the optional IPB through-door ribbon

The batteries may be cable is plugged in correctly (if applicable). The

depleted.

red wire should be on the left and not pinched in

If applicable, the IPB the door.

through-door ribbon cable may not be properly plugged in, or may have bent pins.

Check that there are no bent pins on the optional IPB through-door cable.
Refer to the installation instructions that came with the CO-100 lock, or this user guide for

details on the above mentioned procedures.

Wired remote The lock may not

Wired remote release is available only on the

release feature is be compatible with CO-100 Office function.

not working.

remote release.

Wired remote release is compatible with locks

The firmware

programmed with CO-100 version 2.6.2 firmware

version may not

or higher.

be compatible with remote release.

Check that the switch closes and delivers less than 5 ohms resistance when activated.

The remote release

switch may not be

functioning correctly.

14 · Schlage · CO-100 user guide

FCC Statements
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. this device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may
cause undesired operation.
15 · Schlage · CO-100 user guide

Customer Service
1-877-671-7011 www.allegion.com/us

© Allegion 2020 Printed in U.S.A. P516-270 Rev. 03/20-L

