Carrier 38MHRCQ Ductless Mini-Split System

Outdoor Unit Single Zone Ductless System - Sizes 09 to 24

Product Data

INDUSTRY LEADING FEATURES / BENEFITS

A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT.

The 38MHRCQ series ductless systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.

The ductless system permits creative solutions to design problems such as:

The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use ductwork.

The compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels.

Key Features and Benefits

Inverter Technology

The inverter driven compressor is designed to run at various input power frequencies (Hz) which controls the compressor's motor speed.

Fast Installation

This compact ductless system is simple to install, requiring only wires and piping between indoor and outdoor units. This ensures minimal disruption for retrofit applications.

Simple Servicing and Maintenance

The outdoor unit's top panel provides access to the control compartment for troubleshooting. The draw-thru design allows coils to be cleaned easily from the inside. Indoor units have permanent, easy-to-clean filters, and error codes are displayed on the front panel.

Built-in Reliability

Units are designed for years of trouble-free operation. The microprocessor detects abnormal conditions and stops the unit, displaying an error code. Inverter systems offer additional reliability with soft start, which reduces voltage and current during startup, minimizing electrical stress and wear on components.

Agency Listings

All systems are listed with AHRI (Air conditioning, Heating, and Refrigeration Institute) and are UL certified per UL 60335-2-40 standard.

Model Number Nomenclature

The model number indicates key features of the unit:

Standard Features and Accessories

Outdoor Units

Accessories

Outdoor Unit Model Number Base Pan Base Rubber Plugs RCD Part No. Quantity per Unit
38MHRCQ12AA1 12600801A00077 32
38MHRCQ09AA3 26
38MHRCQ12AA3 34
38MHRCQ18AA3
38MHRCQ24AA3

Note: The base pan has multiple holes for proper draining. Rubber plugs are available to seal these holes and redirect condensate drain.

Dimensions

Detailed dimensions for various system sizes are provided in tables and diagrams. Key dimensions include Height, Width, and Depth for the unit and packaging, along with Net and Gross Weight.

(Refer to page 5, 6, and 7 for detailed dimension tables and diagrams)

Clearances

Minimum clearances are required around the outdoor unit for proper airflow and service access. Specific clearance requirements are detailed for single units and multiple unit arrangements.

(Refer to page 8 for detailed clearance diagrams and requirements)

Specifications

Comprehensive specifications are provided, including:

(Refer to page 9 for detailed specifications)

Performance Data

Cooling and Heating performance data is provided in detailed tables, including:

(Refer to page 10-14 for detailed performance data tables)

Application Data

Unit Selection

Select equipment that matches or slightly exceeds the anticipated peak load for better humidity control and reduced part-load operation. For high sensible loads, base selection on unit sensible load.

Unit Mounting (Outdoor)

Units should be level in all planes. Minimum clearances must be provided for airflow. Locations should be convenient for installation, not exposed to strong winds, and capable of supporting the unit's weight. Avoid special environmental conditions.

Metering Devices

The outdoor unit uses a capillary tube to manage refrigerant flow to the fan coil.

Drain Connections

Install drains according to local sanitation codes.

Refrigerant Lines

Outdoor units are shipped with R410A refrigerant. Line sizing and capacities are based on 25 ft. (7.6 m) runs. For longer runs, refer to Long Line Applications for charge adjustments. Refrigerant lines should not be buried; if necessary, bury no more than 36 inches (914 mm) and provide a minimum 6-inch (152 mm) vertical rise. Use at least 1/2-inch (12.7 mm) thick closed-cell insulation. Isolate tubing to prevent vibration transmission.

Long Line Applications

(Refer to page 15 for Application Data details)

Wiring

All wires must be sized per NEC or CEC and local codes. Use the Electrical Data table for MCA and MOCP to size wires and disconnects. Power and communication wiring from the outdoor to indoor unit consists of four wires (line voltage AC power, communication, and ground). Wiring is polarity sensitive. BX wire is not recommended. For high EMF areas, a shielded wire can be used, landing the shield to ground in the outdoor unit only.

CAUTION: Failure to follow wiring precautions may result in equipment damage or improper operation. Ensure all wiring is tightly connected and no wires touch refrigerant tubing, compressor, or moving parts. Disconnecting means must be provided and located within sight and accessible.

(Refer to page 16 for detailed wiring information)

Wiring Diagrams

Wiring diagrams are provided for different unit sizes (12K 115V, 9-18K 208-230V, and 24K 230V), illustrating connections for the main board, sensors, fan, compressor, and power supply.

(Refer to page 19, 20, and 21 for detailed wiring diagrams)

Electrical Data

Detailed electrical data is presented in a table, including:

(Refer to page 18 for detailed Electrical Data)

Sound Data

Sound pressure and sound power levels are provided for various unit sizes and operating conditions (cooling and heating). Sound pressure in octave bands is also detailed.

(Refer to page 17 for detailed Sound Data)

Guide Specifications

This section provides a comprehensive overview of the unit's design and components:

(Refer to page 22 for detailed Guide Specifications)

PDF preview unavailable. Download the PDF instead.

38MHRC-01PD Acrobat Distiller 20.0 (Windows)

Related Documents

Preview 38MHRC Outdoor Unit Installation Instructions
Comprehensive installation guide for the 38MHRC Outdoor Unit Single Zone Ductless System, covering safety, system requirements, piping, wiring, dimensions, clearances, and start-up procedures.
Preview Carrier 40MBDQ Ducted Slim Ductless System Installation Instructions
Comprehensive installation guide for Carrier 40MBDQ Ducted Slim Ductless Systems (Sizes 09K to 58K), covering safety, requirements, wiring, piping, and troubleshooting.
Preview Carrier 38MHRC Ductless System Installation Instructions
Comprehensive installation guide for the Carrier 38MHRC Outdoor Unit Single Zone Ductless System, covering heat pump and cooling-only models. Includes detailed steps for installation, wiring, piping, safety precautions, and troubleshooting.
Preview 45MBAAQ Split-Type Air Handler Indoor Unit Ductless System Owner's Manual
Comprehensive owner's manual for the Carrier 45MBAAQ Split-Type Air Handler Indoor Unit Ductless System (Sizes 18K-60K). Covers safety, installation, operation modes (Cool, Heat, Dry, Fan, Auto), wireless remote control, care, maintenance, troubleshooting, and error codes for optimal performance and reliability.
Preview Carrier Ductless Systems Compatibility Charts
Comprehensive compatibility charts for Carrier's Ductless Systems, detailing compatible indoor and outdoor units for Single Zone, Multi-zone, and Controls applications across various series.
Preview Carrier Ductless Split System Installation Guide (40GVC/38GVC, 40GVQ/38GVQ)
Comprehensive installation instructions for Carrier 40GVC/38GVC and 40GVQ/38GVQ high-wall ductless split systems, covering safety, system requirements, dimensions, clearances, installation steps, wiring, and troubleshooting.
Preview Carrier 38MVRA Ductless System Product Data
Comprehensive product data for the Carrier 38MVRA Outdoor Unit Single Zone Ductless System, including features, benefits, specifications, dimensions, performance data, and wiring diagrams.
Preview Carrier 40MBDAQ Ducted Slim Ductless System Product Data and Specifications
Comprehensive product data and specifications for the Carrier 40MBDAQ series of ducted slim ductless HVAC systems, covering features, dimensions, performance, and installation details.