Product Overview
The R. STAHL 8602/3 series actuators are designed for extreme conditions, offering robust performance. They are suitable for use in ambient temperatures ranging from -60 °C to +70 °C, while maintaining an IP66 degree of protection in accordance with EN 60529. A single axial actuator from the 8602/3 series can operate up to four contact elements from the 8082 series. The integrated coding option for key switches and rotary switches allows for easy adjustment of "latching/spring return" and "key not removable" functions without additional accessories. A range of accessories, including label holders and locking devices, is available.
This product is [Explosion Protected] rated.
Key Features
- Includes pushbutton, mushroom pushbutton, mushroom stay-put button with key lock, mushroom stay-put button, twin pushbutton, and illuminated pushbutton options. Also available as a rotary actuator, key-operated switch, potentiometer bezel, and indicator lamp bezel.
- A single axial actuator can operate up to four 8082 series contact elements.
- Key-operated switches and rotary switches are codable at any time for "latching/spring return" or "key not removable" functions.
Technical Data
Explosion Protection
Category | Details |
---|---|
Application range (zones) | 1, 2, 21, 22 |
IECEx gas certificate | IECEx PTB 13.0047U |
IECEx gas explosion protection | Ex eb IIC Gb |
IECEx dust certificate | IECEx PTB 13.0047 U |
IECEx dust explosion protection | Ex tb IIIC Db |
ATEX gas certificate | PTB 13 ATEX 1019 U |
ATEX gas explosion protection | II 2 G Ex eb IIC Gb |
ATEX dust certificate | PTB 13 ATEX 1019 U |
ATEX dust explosion protection | II 2 D Ex tb IIIC Db |
UL gas certificate | E182378 V4 S2 |
Inmetro gas certificate | UL-BR 14.0380U |
Inmetro dust certificate | UL-BR 14.0380U |
Certificates | ATEX (PTB), Brazil (ULB), Canada / USA (UL), EAC (ENDCE), IECEx (PTB), India (PESO), Korea (KGS) |
Ambient Conditions
Parameter | Value |
---|---|
Ambient temperature | -20 °C ... +60 °C |
Ambient temperature | -4 °F ... +140 °F |
Storage temperature | -25 °C ... +60 °C |
Storage temperature | -13 °F ... +140 °F |
Use at the height of | < 2000 m |
Mechanical Data
Property | Specification |
---|---|
Degree of contamination | 3 |
Version | increased height, bk-bk |
Degree of protection (IP) | IP66 |
Note on degree of protection | According to IEC/EN 60529 |
Enclosure material | Polyamide |
Silicone-free | Yes |
Assembly | 728 |
Diameter | 65 mm |
Service life, min. | 10⁵ actuations |
Impact strength (IEC 60079) | 7 J |
Impact strength (IEC 62262) | min. IK08 |
Handle colour | Black |
Protective collar colour | Black |
Fastening | Thread type |
Designation plate | 0/OFF – I/ON |
Seal | Standard |
Lockable in | 90° |
Packaging unit | 1 |
Weight | 0.04 kg |
Weight | 0.09 lb |
Description note | Lockable option (max. 3 times) can be determined using the enclosed closing parts. Lockable handle position: 90°. In the unmounted assemblies, the standard label is 0/OFF-I/ON and the long coupling part is enclosed. Other labels must be ordered separately. |
Mounting / Installation
Parameter | Value |
---|---|
Mounting type | Not installed |
Tightening torque | 3 Nm |
Tightening torque lbf in | 26.55 lbf in |
Technical Drawings and Dimensions
Front Installation Mounting Diagram
A diagram illustrates the front installation mounting of the actuator with control switch series 8008. It details the assembly of components including the actuator (5), seal (4), jam nut (2), installation wall (3), adaptor (33), control switch (18), disc (34), and screw (35).
Legend:
- 2 = Jam nut (order no. 205592)
- 3 = Installation wall (wall thickness max. 2 mm [0.0787in])
- 5 = Actuator 8302/3 with seal (4)
- 18 = Control switch 8008/2-.
- 33 = Adaptor 8602/3 for front installation for type 8008/2
- 34 = Disc M4
- 35 = Screw M4x
Explanation Position Display
Diagram showing the explanation of switch positions: '0/OFF' and 'I/ON', with the handle lockable in the 'I/OFF' position at 90°.
Dimensional Drawings (All Dimensions in mm [inches])
Multiple circular diagrams detail the actuator's dimensions. Key dimensions include overall diameter Ø 65 [Ø 2.56], a central hole diameter of Ø 30.50 ±0.1 [Ø 1.20±0.004], and various other mounting and profile measurements. A separate diagram shows a single perforation pattern.
Actuator Variants
The document specifies different actuator models:
- 8602/3-728 Rotary actuator, black handle, red protective collar
- 8602/3-729 Rotary actuator, red handle, black protective collar
- Actuator with radial actuation
Accessories
Accessory | Art. No. |
---|---|
Cylinder lock | 107115 |
Spare Parts
Labels for large BG 728, BG 729, BG 730, BG 731 rotary actuator
Label Description | Art. No. |
---|---|
Ø 58 0/OFF I/ON | 227004 |
Ø 58 0 BETRIEB I | 227005 |
Ø 58 0 I II | 227006 |
Ø 58 I 0 II | 227007 |
Ø 58 I II | 227008 |
Ø 58 0 I | 227009 |
Ø 58 I 0 I 0 | 227010 |
Ø 58 HAND 0 AUTO | 227011 |
Ø 58 0/OFF o I/ON | 227012 |
Ø 58, yellow 0/OFF I/ON | 227013 |
Ø 58 0 I (90°) | 273760 |
Ø 58 plain | 227014 |
Special Parts
Part | Description | Art. No. |
---|---|---|
Special key | for tightening plastic locking nut | 169101 |
Adaptor for front installation | 8602/3 Front installation for control switch series 8008 | 260081 |