SolarEdge TerraMax™ Inverter & H1300 Power Optimizer
For Europe and International Markets
Featuring: and 5 YEAR WARRANTY 25 YEAR WARRANTY
[Image: SolarEdge TerraMax Inverter]
[Image: H1300 Power Optimizer]
Groundbreaking versatility. Greater yields.
Versatile
- ✔️ Enables PV deployment on sloped, uneven, or irregular-shaped terrain
- ✔️ Ideal for placement above crops or on bodies of water
- ✔️ Ideal for both centralized and distributed topologies
- ✔️ Long strings requiring less cabling
Powerful
- ✔️ MLPE-based solution
- ✔️ 99% inverter efficiency
- ✔️ Offsets module mismatch
- ✔️ 200% DC oversizing
- ✔️ Integrated night-time PID rectifiers
Granular Visibility
- ✔️ High precision monitoring and smart PV fleet management
- ✔️ Pinpointed visibility into site performance
- ✔️ Easy spotting of potential faults and remote troubleshooting
- ✔️ Reduced service visits increase system uptime and lowers O&M costs
Safe and Secure
- ✔️ Global safety and cybersecurity standards
- ✔️ Multilayered protection from inverter to cloud
- ✔️ Addresses various safety requirements throughout the system lifetime
- ✔️ SafeDCTM – designed to automatically reduce DC voltage to touch-safe levels
Visit: solaredge.com
Inverter Technical Specifications
SE300K(1) / SE330K
SE300K(1) | SE330K | Units | |
---|---|---|---|
OUTPUT | |||
Rated AC Active Output Power | 297,000 @ 45°C | 330,000 @ 45°C | W |
Maximum Apparent AC Output Power | 297,000 @ 45°C | 330,000 @ 45°C | VA |
AC Output Voltage - Line to Line (Nominal) | 690 | 690 | Vac |
AC Output Voltage - Line to Line (Range) | 587-759 | 587-759 | Vac |
AC Frequency | 50 ± 5% | 50 ± 5% | Hz |
Rated Continuous Output Current (per Phase) @Nominal Voltage | 276.1 | 276.1 | Aac |
AC Output Line Connections | 3W + PE | 3W + PE | |
Total Harmonic Distortion | ≤3 | ≤3 | % |
Utility Monitoring, Islanding Protection, Configurable Power Factor, Country Configurable Thresholds | Yes | Yes | |
Power Factor Range | 0.2-1 / leading, lagging | 0.2-1 / leading, lagging | |
INPUT | |||
Maximum DC Power (Module STC) | 594,000 | 660,000 | W |
Maximum Input Voltage DC+ to DC- | 1500 | 1500 | Vdc |
Nominal DC Input Voltage DC+ to DC- | 1250 | 1250 | Vdc |
Maximum Input Current | 266.7 | 266.7 | Adc |
Module-Level Optimization | Yes | Yes | |
EFFICIENCY | |||
Maximum Efficiency / EU Efficiency | 99.2 / 98.8 | 99.2 / 98.8 | % |
PROTECTION FEATURES | |||
DC Reverse Polarity Protection | Yes | Yes | |
Ground Fault Isolation Detection | Yes | Yes | |
AC Surge Protection | Type 2, monitored and field replaceable | Type 2, monitored and field replaceable | |
DC Surge Protection | Type 2, monitored and field replaceable | Type 2, monitored and field replaceable | |
CAN, RS485 Surge Protection | Yes | Yes | |
DC Disconnect | Yes, integrated | Yes, integrated | |
ADDITIONAL FEATURES | |||
Supported Communication Interfaces | CAN bus, RS485, Ethernet, WiFi, Cellular (optional) | CAN bus, RS485, Ethernet, WiFi, Cellular (optional) | |
PID Protection | PID Rectifier | PID Rectifier | |
Inverter Commissioning | With the SetApp mobile application using built-in Wi-Fi access point for local connection | With the SetApp mobile application using built-in Wi-Fi access point for local connection | |
Pre-Commissioning | Inverter activation and validation powered by PV modules | Inverter activation and validation powered by PV modules | |
VAR at Night | Yes | Yes | |
STANDARD COMPLIANCE | |||
Safety | IEC 62109 | IEC 62109 | |
Grid Connection Standards | VDE-AR-N 4110, VDE-AR-N 4120 | VDE-AR-N 4110, VDE-AR-N 4120 | |
EMC | IEC/EN 61000-6-2, IEC 61000-6-4, EN 55011, CISPR 11, IEC 62920 | IEC/EN 61000-6-2, IEC 61000-6-4, EN 55011, CISPR 11, IEC 62920 | |
RoHS | Yes | Yes | |
GENERAL DATA | |||
Dimensions (W x H x D) | 1090 x 914 x 416 / 42.91 x 35.98 x 16.38 | 1090 x 914 x 416 / 42.91 x 35.98 x 16.38 | mm/in |
Weight | 163 / 359 | 163 / 359 | kg/lb |
Operating Temperature Range | -40 to +60 / -40 to +140(2) | -40 to +60 / -40 to +140(2) | °C/°F |
Cooling | Fans (field replaceable) | Fans (field replaceable) | |
Noise Emission | < 72 | < 72 | dBA |
Protection Rating | IP66 | IP66 | |
Mounting | Bracket provided | Bracket provided | |
Topology | Transformerless | Transformerless | |
AC Connection(3) | 2 Glands, Cable Diameter 48-55mm, Terminal Lugs, Max. 300mm² per wire, Al or Cu | 2 Glands, Cable Diameter 48-55mm, Terminal Lugs, Max. 300mm² per wire, Al or Cu | |
DC Connection(4) | 4 Glands, Cable Diameter 22-32mm, Terminal Lugs, Max. 300mm² per wire, Al or Cu | 4 Glands, Cable Diameter 22-32mm, Terminal Lugs, Max. 300mm² per wire, Al or Cu |
(1) Available in DACH countries that follow VDE-AR-N-4110/VDE-AR-N-4120.
(2) For ambient temperatures above +45°C / 113°F power derating is applied. Refer to the Temperature Derating technical note for more details.
(3) Two AC terminals per line are available.
(4) Two sets of DC terminals (+, -) are available.
Power Optimizer Technical Specifications
H1300
H1300 | Units | |
---|---|---|
INPUT | ||
Rated Input DC Power(1) | 1300 | W |
Connection Method | Single input for series connected modules | |
Absolute Maximum Input Voltage (Voc at lowest temperature) | 125 | Vdc |
MPPT Operating Range | 12.5-105 | Vdc |
Maximum Continuous Input Current | 15 | Adc |
Maximum Short Circuit Current (Isc) of Connected PV Module | 20 | Adc |
Maximum Efficiency | 99.5 | % |
Weighted Efficiency | 98.8 | % |
Overvoltage Category | II | |
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) | ||
Rated Output Current | 20 | Adc |
Rated Output Voltage | 75 | Vdc |
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR INVERTER OFF) | ||
Safety Output Voltage per Power Optimizer | 1 ± 0.1 | Vdc |
STANDARD COMPLIANCE | ||
EMC | FCC Part 15 Class A, IEC 61000-6-2, IEC 61000-6-4, EN 55011 | |
Safety | IEC 62109-1 (Class II safety) | |
Material | UL94 V-0, UV resistant | |
ROHS | Yes | |
Fire Safety | VDE-AR-E 2100-712:2013-05 | |
INSTALLATION SPECIFICATIONS | ||
Compatible SolarEdge Inverters | SolarEdge TerraMax™ Inverter SE300K and SolarEdge TerraMax™ Inverter SE330K | |
Maximum Allowed System Voltage | 1500 | Vdc |
Dimensions (W x L x H) | 129 x 155 x 59 / 5.08 x 6.10 x 2.32 | mm/in |
Weight (including cables) | 1170 / 2.6 | g/lb |
Input Connector | MC4-Evo2(2) | |
Input Wire Length | 0.16, 0.16 / 0.52, 0.52 | m/ft |
Output Connector | MC4-Evo2 | |
Output Wire Length | 0.1, 5.3 / 0.32, 17.39 | m/ft |
Operating Temperature Range(3) | -40 to +65 / -40 to +149 | °C/°F |
Protection Rating | IP68 / NEMA6P | |
Relative Humidity | 0-100 | % |
(1) The rated power of the module at STC will not exceed the power optimizer's Rated Input DC Power. Modules with up to +5% power tolerance are allowed.
(2) For other connector types please contact SolarEdge.
(3) For ambient temperatures above +65°C / 149°F power derating is applied. Refer to the Temperature Derating technical note for more details.
String Length and Power Capacity
Module Power | Minimum String Length(4) (Power Optimizers/Modules) | Maximum String Length (Power Optimizers/Modules) | Maximum Continuous Power per String | Maximum Allowed Connected Power per String | Maximum allowed difference between the shortest and longest string connected to the same inverter | Units |
---|---|---|---|---|---|---|
400-450W | 27/54 | 40/80 | 25,000 | 33,000(5) | 5 Power Optimizers | W |
455-550W | 24/48 | 40/80 | 25,000 | 33,000(6) | 5 Power Optimizers | W |
555-650W | 22/44 | 40/80 | 25,000 | 33,000(6) | 5 Power Optimizers | W |
(4) Design your project using SolarEdge Designer to use a lower minimum string length and/or connect more STC power per string.
(5) For the SE300K, a minimum of 12 strings must be connected. For 11 strings or less, 29,000W is allowed.
(6) For the SE330K, a minimum of 14 strings must be connected. For 13 strings or less, 29,000W is allowed.
About SolarEdge
SolarEdge is a global leader in smart energy technology. By leveraging world-class engineering capabilities and with a relentless focus on innovation, SolarEdge creates smart energy solutions that power our lives and drive future progress.
SolarEdge developed an intelligent inverter solution that changed the way power is harvested and managed in photovoltaic (PV) systems. The SolarEdge DC optimized inverter maximizes power generation while lowering the cost of energy produced by the PV system.
Continuing to advance smart energy, SolarEdge addresses a broad range of energy market segments through its PV, storage, EV charging, UPS, and grid services solutions.
Connect with SolarEdge: SolarEdge, @SolarEdgePV, @SolarEdgePV, SolarEdge
More information: www.solaredge.com/corporate/contact
Legal Notice: SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: April 10, 2025 DS-000099-ENG. Subject to change without notice.
Cautionary Note: This brochure may contain market data and industry forecasts from certain third-party sources. This information is based on industry surveys and the preparer's expertise. There can be no assurance that any such market data is accurate or that any such industry forecasts will be achieved. Although SolarEdge has not independently verified the accuracy of such market data and industry forecasts, SolarEdge believes that the market data is reliable and that the industry forecasts are reasonable.
[CE Mark]