LS S300 High Performance Drive

3-Phase 200V Type: 0.5 ~ 100HP (0.4 ~ 75kW)

3-Phase 400V Type: 0.5 ~ 350HP (0.4 ~ 220kW)

1. Flexibility

Designed Compact

Smaller size than the previous model Starvert-iS7 Series.

World Best Compact Size
Based on 200HP, 250HP 400V Class.

Product Size Comparison for 400V type

Frame Power iS7 Size (W x H x D) S300 Size (W x H x D) S300 / iS7
FR1 0.4~3.7 150.0 284.0 200.0 150.0 276.0 194.0 94.3%
FR2 5.5, 7.5 200.0 355.0 225.0 180.0 310.0 225.0 78.6%
FR3 11, 15 250.0 385.0 284.0 200.0 355.0 225.0 58.4%
FR4 18.5, 22 280.0 461.6 298.0 240.0 424.0 265.0 70.0%
FR5 30, 37 300.1 594.1 303.2 252.0 500.0 271.0 63.2%
FR6 45 300.1 594.1 303.2 300.0 510.0 298.6 84.5%
FR7 55,75 370.1 663.5 373.3 350.0 615.0 320.0 75.1%
FR8 90, 110 510.0 783.5 422.6 300.0 706.0 386.0 48.4%
FR9 132, 160 510.0 861.0 422.6 380.0 705.0 396.0 57.2%
FR10 185, 220 690.0 1078.0 450.0 426.0 922.3 440.0 51.6%

Max. 52% Smaller than iS7

For more information, refer to the Appendix A.

Various Options

Various options are available, and more options will be released in the near future.

  • Communication Options: RAPIENET+ (RAPIEnet, EtherNet/IP, Modbus TCP), PROFINET
  • Encoder Options: Pulse Open Collector Encoder (15V/24V), Pulse Line Drive Encoder (15V/12V)
  • I/O Expansion Option: DI: 3P(NO/NC selectable), DO: 2P(NPN/PNP Selectable), AI: 2P, AO: 1P

[Diagram showing drive with connection options: Conduit Option, Flange Option]

Motor Compatibility

S300 is a universal drive designed for all applications, offering seamless control of SynRM (Synchronous Reluctance Motor), PM Motor (Permanent Magnet Motor), and IM (Induction Motor) with maximum versatility and efficiency.

  • IM, PMSM and SynRM control
  • Achieving IE4 Efficiency
  • Max. 40% Energy Reduction
  • Lower carbon footprint

※ SynRM control algorithm will be available in a few years.

2. Safety

Reliability/Quality

  • Global Specification Satisfied: UL, CE, KC, RoHS conformity registration.
  • Built-in EMC: EN 61800-3:2018 / Category C3 (Class A)
  • LVD: EN 61800-5-1:2007 (2nd Edition)

Safety Torque Off

  • European Machinery Directive 2006/42/EC
  • EN 61800-5-2:2017 SIL2
  • EN ISO 13849-1:2023 Category 3, PL d
  • EN 61508:2010 SIL2

IP rating

  • 0.4~75kW-2, 0.4~160kW-4: IP20 (UL Open Type, UL Type 1)
  • 185~220kW-4: IP00

[UL, CE, RoHS logos]

Safety Torque Off

  • S300 provides contactor-less operation with STO (Safety Torque Off).
  • Engineered to meet rigorous safety standards, S300 is certified for EN ISO 13849-1 PLd and IEC 61508 SIL2, ensuring reliable operational safety across diverse industrial environments.

STO Wiring Diagrams

[Diagram illustrating STO wiring with Application, STO A, STO B, MCU, Gate Driver, Fault Relay, and Motor connections]

※ The factory setting for SP-SA and SP-SB is short circuit by a factory installed jumper.

3. Easy Engineering

Smart LCD Operator

  • Experience smarter control with our high-resolution LCD keypad, supporting multi-language display for global usability: Currently supports English and Korean (Italian, Polish, Spanish, German, French, Turkish will be supported).
  • Easily save and back up data via the built-in USB port, with memory storage functionality.
  • Add an RTC battery to enable real-time data logging—ideal for precision and traceability.

Two USB Type-C
Easily save and back up data via the built-in USB port, with memory storage functionality.

RTC (Real Time Clock)
When a battery is inserted into the SLO, the exact fault time can be logged.

[Image of LCD keypad and RTC battery installation]

USB Memory Function

  • Effortlessly keep your S300 drive up-to-date with our user-friendly software upgrade process.
  • Utilize a PC and simple SLO interface to seamlessly update firmware and features, ensuring optimal performance and access to the latest enhancements.

Easy Firmware Upgrade
There are two ways to upgrade your drive to the latest version:

  1. Writing directly the S300 control software file (HEX extension) to the S300 through DriveView9
  2. Copy the S300 control software file (BIN ext.) to the SLO in USB mode

Parameter Copy
Parameter save file or Screen capture image can be moved from SLO to PC.

[Diagram showing firmware upgrade process and parameter copy between S300 units and PC]

PC Engineering Tool

  • Easily back up S300's configurations with a SLO or use the configuration tool DriveView9. (DriveView9 can be downloaded from LS ELECTRIC's official website for free)
  • A SLO provides clear parameter descriptions and units. All laid out in a logical sequence to support a rapid and effortless system start up.

Simple Scope in DriveView9
Edit parameters and monitor parameters as graphs (8 channels).

Advanced User Sequence
With DriveView9, Use the full potential of Advanced User Sequence. A PC can be connected via USB port of S300.

[Screenshots of DriveView9 interface showing parameter monitoring and advanced user sequence]

Predictive Maintenance

Maximize uptime with predictive maintenance: anticipate issues before they occur and keep your operations running smoothly. Transform your maintenance strategy with data-driven insights for a more reliable future.

  • Capacitor: Deterioration Diagnostic, Diagnostic cycle alarm, Replacement Cycle Warning
  • Fan: Main Fan Life Diagnostic, Auxiliary Fan Life Diagnostic
  • Relay: Pre-charge Relay Life Diagnostic

[Diagram illustrating predictive maintenance for Capacitor, Fan, and Relay]

4. Upgraded Features

Improved Sensorless Control

Improved Auto tuning algorithm and Dead time compensation enables powerful starting torque and stable torque control.

Powerful Starting Torque
Test condition: 50 N.m Torque load, 60Hz, Acc time: 1sec.

[Comparison graphs showing S300 vs. iS7 for starting torque]

Stable Torque Output
7.5kW 400V Sensorless Performance Data (Auto tuned)

[Comparison graphs showing S300 vs. iS7 for stable torque output]

Upgraded User Sequence

  • With 100 function blocks, User Sequence enables us to effortlessly customize and automate operations. Create tailored sequences to streamline processes, enhance productivity, and adapt quickly to changing needs.
  • Real-time parameter monitoring is provided in DriveView9
LS ELECTRIC LV Drive Series
Product Name S100 G100 S300
Control cycle time 10~1000ms 10~1000ms 10~1000ms
Provided functions 28 types 28 types 43 types (Logic function 10 types + Value function 33 types)
Maximum number of Blocks 18 18 100 (Expandable)
User Custom Block Creation X X O
Real Time Monitoring X X O (DriveView9)

Simple Master

  • Simple Master is a function that allows one S300 to act as a communication master and operate multiple drives as slaves.
  • It's possible to transfer some data or commands between master and slaves.
  • All drives should be connected by RS485 communication.

[Diagram showing S300 Master controlling multiple S300 slaves via RS485]

Appendix A. Specification

1. Input & Output (1)

Series S300
0.4kW 0.8kW 1.5kW 2.2kW 4kW 5.5kW 7.5kW 11kW 15kW 18.5kW 22kW 30kW 37kW 45kW 55 kW 75 kW 90kW 110kW 132kW 160kW 185kW 220kW
Frame FR1 FR2 FR3 FR4 FR5 FR6 FR7 FR8 FR9 FR10
Input Voltage [V] 3 phase 200 ~ 240, -15%~+10% 3 phase 380~480, -15%~+10%
200V Output Voltage [V] 3 phase 200 ~ 240
Output Current [A] HD 3.2 5 8 11 17.5 25 33 47 60 75 88 115 145 180 220 288
ND 5 8 12 16 22 30 42 56 70 82 110 138 169 211 288 345
400V Output Voltage [V] 3 phase 380~480
Output Current [A] HD 1.8 3.4 4.8 5.5 9.2 14.8 16.5 24 31 39 45 61 75 91 110 152 183 223 264 325 370 425
ND 2.5 4.1 6 8 12.1 17.5 24 31 38 45 61 75 91 107 142 169 223 264 325 370 432 481
Common Input Freq[Hz] 50/60 ±5%
Output Freq[Hz] 0~590

2. Structure (1)

Protection structure IP 20 (Basic), Satisfy UL Enclosed Type 1 when UL Open & Enclosed Type 1 (Option) Conduit Option is installed
Cooling type Forced fan cooling
Mounting type Wall-mount Type

3. Control Specification

Series S300 Standard
Control method V/F Control, Sensorless vector, Slip Compensation, V/F PG, Vector
Control function Refer to the functional specifications
Operating method Select one among Smart operator, Terminal block, Communication
Frequency settings power resolution Digital command: 0.01Hz Analog command: 0.06Hz (Max frequency: 60Hz)
Frequency accuracy V/f pattern 1% of Max output frequency
Linear, Square reduction, User V/F
Overload capacity HD - 1min at 150%
ND: 200V-45kW and less: 120% 1 min, 55kW and above: 110% 1 min
400V-75kW and less: 120% 1 min, 90kW and above: 110% 1min
Torque boost Manual torque boost, Auto torque boost
Switching frequency 1~15kHz
Built-in DC chopper 18.5kW-2, 37kW-4 and less: Built-in Standard, 22kW-2, 45kW-4 and above: External Option

4. Standards

Standards UL, CE, KC
IP IP 20 (Basic), Satisfy UL Enclosed Type 1 when UL Open & Enclosed Type 1(Option) Conduit Option is installed

5. Environment

Operating temperature HD : -10~50°C, ND : -10~40°C
Storage temperature -10~50°C (40°C and above: 2.5%/°C Current derating, 50°C: 75% of the rated current)
Humidity Relative humidity less than 95% RH (to avoid condensation forming)
Oscillation & Altitude 1,000m and less, 9.8m/sec ² (1.0G) and less
Pollution Degree Pollution Degree 2 Environment

Appendix B. Comparison

1. Size Comparison

400V type

Frame Power iS7 Size (W x H x D) Vol. S300 Size (W x H x D) Vol. S300 / iS7 400V type kW S300 iS7 S300 iS7
FR1 0.4~3.7 150.0 284.0 200.0 8.5 l 150.0 276.0 194.0 8.0 l 94.3% 0.4
FR2 5.5, 7.5 200.0 355.0 225.0 16.0 l 180.0 310.0 225.0 12.6 l 78.6% 0.75
FR3 11, 15 250.0 385.0 284.0 27.3 l 200.0 355.0 225.0 16.0 l 58.4% 1 1 (8.0l) 1 (8.0l) 1.5 1 (8.0l) 1 (8.0l)
FR4 18.5, 22 280.0 461.6 298.0 38.5 l 240.0 424.0 265.0 27.0 l 70.0% 2.2 (8.5l) 1 (8.5l)
FR5 30, 37 300.1 594.1 303.2 54.1 l 252.0 500.0 271.0 34.1 63.2% 3.7
FR6 45 300.1 594.1 303.2 54.1 l 300.0 510.0 298.6 45.7 l 84.5% 5.5 2 2 2 2 2
FR7 55,75 370.1 663.5 373.3 91.7 l 350.0 615.0 320.0 68.9 75.1% 7.5 (12.6l) (16.0l) (12.6l) (16.0l)
FR8 90, 110 510.0 783.5 422.6 168.9 300.0 706.0 386.0 81.8 l 48.4% 11.0 3 3 3 (16.0l)
FR9 132, 160 510.0 861.0 422.6 185.6 l 380.0 705.0 396.0 106.1 l 57.2% 15.0 (16.0l) (27.3l) 4 (27.3l)
FR10 185, 220 690.0 1078.0 450.0 334.7 l 426.0 922.3 440.0 172.9 51.6% 18.5 4 4 (27.0l) 5 (34.1l)

200V type

Frame Power iS7 Size (W x H x D) Vol. S300 Size (W x H x D) Vol. S300 / iS7 200V type
kW S300 iS7 S300 iS7 S300 iS7
FR1 0.4~3.7 150.0 284.0 200.0 8.5 l 150.0 276.0 194.0 8.0 l 94.3% 0.4
FR2 5.5, 7.5 200.0 355.0 225.0 16.0 l 180.0 310.0 225.0 12.6 l 78.6% 0.75
FR3 11 250.0 385.0 284.0 27.3 l 200.0 355.0 225.0 16.0 l 58.4% 1 1 (8.0l) 1 (8.0l) 1.5 1 (8.0l) 1 (8.0l)
FR4 15 250.0 385.0 284.0 27.3 l 240.0 424.0 265.0 27.0 l 98.7%
FR4 18.5 280.0 461.6 298.0 38.5 l 240.0 424.0 265.0 27.0 l 70.0%
FR5 22 280.0 461.6 298.0 38.5 l 252.0 500.0 271.0 34.1 l 88.7%
FR6 30 300.0 570.0 265.2 45.3 l 300.0 510.0 298.6 45.7 l 100.7%
FR7 37, 45 370.0 630.0 281.2 65.5 l 350.0 615.0 320.0 68.9 l 105.1%
FR9 55,75 465.0 750.0 355.6 124.0 l 380.0 705.0 396.0 106.1 l 85.5%

2. Terminal Comparison

[Diagram showing terminal layout for S300 and iS7]

Category Naming S300 I/O iS7 I/O
Terminal Block Type DI1~D18 Detachable type I/O 33pin (5mm pitch) Detachable type I/O 33pin
Digital Input DP, DG 8 EA 8 EA
Digital Power Output DA1, DB1, DC1, DA2, DC2, DQ3, EG 24V 24V
Digital Output 3-contact terminal 1EA, 2-contact terminal 1EA, O.C 1EA 3-contact terminal 1EA, 2-contact terminal 1EA, O.C 1EA
Analog Input AI1~AI3 V/I selectable 3EA V 1EA, I 1EA
Analog Ref. VR+, VR- +10V, -10V +12V, -12V
Analog Output AO1, AO2 Bipolar V / Unipolar I selectable 2EA Bipolar V & Unipolar I selectable 2EA
Pulse Train Input TI 1 EA External option (Encoder)
Pulse Train Output TO 1 EA External option (Encoder)
External DC Input(24V) EPI 1 EA External option (External Power option)
STO SP, SA, SB Provided as standard External option (Safety option)
Internal Comm. S+, S- RS-485 (Terminals, RJ45) RS-485 terminals

LS ELECTRIC Customer Support Platform

SSQ & Youtube Channel

  • Operate various platforms for automation technology content and data download

LS ELECTRIC Youtube: https://youtube.com/c/LSELECTRICAutomationOasis
Providing training videos for automation products on Youtube channel named LS ELECTRIC Automation Oasis

SSQ (Library): https://sol.ls-electric.com/
Providing a various of contents like Training material, Troubleshooting, Success stories, Product Introduction, User manuals on SSQ (Solution Square)

Youtube Channel Introduction

  • Providing training videos for PLC, HMI, SERVO, INV
  • Providing video in Korean/English

[Images of YouTube videos and SSQ interface]

Engineering SW Integration Services

  • Sample, Graphic library download
  • The latest software version check and updates

Quick and Easy Tech Information Search

  • High quality & up-to-date materials on technology and products
  • Easy access to materials in mobile
  • Information sharing through the community.

PDF preview unavailable. Download the PDF instead.

S300 Sales Material 250718 Microsoft PowerPoint Microsoft 365용

Related Documents

Preview LS LV Drive Series: M100, G100, S100, H100+, iS7, SP100 - Variable Frequency Drives
Explore the LS LV Drive Series, featuring M100, G100, S100, H100+, iS7, and SP100 variable frequency drives. Discover advanced features, energy efficiency, and robust performance for diverse industrial and commercial applications from LS ELECTRIC.
Preview LS Drive Series Variable Frequency Drives (VFDs) - Product Catalog
Comprehensive catalog detailing the LS Drive Series of Variable Frequency Drives (VFDs), including models iE5, iC5, iG5A, S100, iS7, iP5A, and iV5. Features, specifications, comparisons, and options for industrial power transmission and motor control applications.
Preview LS ELECTRIC G100/G100C General AC Drive: Features, Specifications, and Wiring
Comprehensive guide to the LS ELECTRIC G100 and G100C General AC Drives, detailing features, specifications, wiring diagrams, keypad functions, and peripheral devices. Learn about their advanced sensorless vector control, user-friendly design, and safety functions like STO.
Preview H100+ VFD PID Setup Quick Start Guide
This quick start reference provides essential information for setting up the PID loop on the LS Electric H100+ Variable Frequency Drive (VFD). It covers transducer identification, wiring, basic parameter configuration, operation verification, and troubleshooting steps.
Preview LS Electric S100 VFD Quick Start Reference Guide
A quick start reference guide for the LS Electric S100 Variable Frequency Drive (VFD), covering models from 0.5 to 100 HP. This guide provides essential information on mounting, wiring, basic programming, and operation, serving as a supplement to the full User Manual.
Preview LS ELECTRIC L7C AC Servo Systems: Features, Specifications, and Selection Guide
Comprehensive overview of LS ELECTRIC's L7C Series AC Servo Systems, detailing drive and motor features, tuning technology, selection criteria, mechanical integration, specifications, and accessories for industrial automation.
Preview LS ELECTRIC G100 PROFIBUS-DP Communication Module User Manual
This manual provides detailed information on the LS ELECTRIC G100 PROFIBUS-DP communication module, including its features, technical specifications, installation, operation, and troubleshooting. Learn how to connect the LSLV-G100 inverter to a PROFIBUS network for enhanced automation and control.
Preview LS ELECTRIC LSLV-G100 Series AC Variable Speed Drive Operation Manual
Operation manual for LS ELECTRIC's LSLV-G100 series AC Variable Speed Drives (0.4-22kW). Covers essential safety guidelines, detailed installation procedures, technical specifications, wiring, and basic operation for industrial applications. Includes information on peripheral device compatibility and software usage.