Instruction Manual for Endress plus Hauser models including: FTL4X, LCGFTL4X, Liquiphant FTL60 IO-Link Point Level Switch for Liquids, Liquiphant FTL60 IO-Link, Point Level Switch for Liquids, Level Switch for Liquids, Switch for Liquids, Liquids, Switch
Endress and Hauser SE Co. KG FTL4X Hygienic point level switch for liquids with BLE TX LCGFTL4X LCGFTL4X ftl4x
File Info : application/pdf, 32 Pages, 937.11KB
DocumentDocumentTI01789F/00/EN/01.24-00 71645388 2024-01-31 Products Solutions Services Technical Information Liquiphant FTL60 IO-Link Vibronic Point level switch for liquids Application · Point level switch for all pumpable liquids, for minimum or maximum detection in vessels, e.g. process tanks, storage tanks, and piping. · Process temperature range: 40 to +150 °C (40 to +302 °F) · Pressures up to 64 bar (928 psi) · Viscosities up to 10 000 mPas · Ideal substitute for float switches as reliable function is not affected by flow, turbulence, air bubbles, foam, vibration, solids content or buildup. Advantages · Easy commissioning with plug and play functionality · Certified, hygienic design (3-A, EHEDG, ASME BPE) · Proven conformity with materials standards, e.g. EC1935/2004, FDA, GB 4806, cGMP · Heartbeat Technology for predictive and preventive maintenance · Bluetooth® wireless technology for commissioning, operation and maintenance · CIP and SIP capabilities - up to protection class IP69 Table of contents Liquiphant FTL60 IO-Link About this document . . . . . . . . . . . . . . . . . . . . . . . . 4 Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 List of abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Graphic conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Function and system design . . . . . . . . . . . . . . . . . . . 5 Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Measuring system . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Communication and data processing . . . . . . . . . . . . . . . . 5 Reliability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Device-specific IT security . . . . . . . . . . . . . . . . . . . . . . . 6 Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Switching capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Signal on alarm for devices with current output . . . . . . . . . 6 Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Damping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Switch output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Protocol-specific data . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Terminal assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Available device plugs . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Potential equalization . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Overvoltage protection . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Performance characteristics . . . . . . . . . . . . . . . . . . . 9 Reference operating conditions . . . . . . . . . . . . . . . . . . . . 9 Take switch point into consideration . . . . . . . . . . . . . . . . . 9 Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Maximum measured error . . . . . . . . . . . . . . . . . . . . . . . 9 Hysteresis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Non-repeatability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Influence of the process temperature . . . . . . . . . . . . . . . . 9 Influence of the process pressure . . . . . . . . . . . . . . . . . . . 9 Influence of the process medium density (at room temperature and normal pressure) . . . . . . . . . . . . . . . . . 10 Response time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Warm-up time (according to IEC62828-4) . . . . . . . . . . . 10 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Installation instructions . . . . . . . . . . . . . . . . . . . . . . . . 11 Installing the device in piping . . . . . . . . . . . . . . . . . . . . 13 Special mounting instructions . . . . . . . . . . . . . . . . . . . . 13 Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Ambient temperature range . . . . . . . . . . . . . . . . . . . . . 14 Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Operating height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2 Climate class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Pollution degree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Shock resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Electromagnetic compatibility (EMC) . . . . . . . . . . . . . . . 15 Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Process temperature range . . . . . . . . . . . . . . . . . . . . . . 15 Thermal shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Process pressure range . . . . . . . . . . . . . . . . . . . . . . . . 16 Test pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Viscosity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Pressure tightness . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Solids contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Mechanical construction . . . . . . . . . . . . . . . . . . . . 16 Design, dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Process connections . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Surface roughness . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Display and user interface . . . . . . . . . . . . . . . . . . . 25 LED indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Remote operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 System integration . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Supported operating tools . . . . . . . . . . . . . . . . . . . . . . 27 Certificates and approvals . . . . . . . . . . . . . . . . . . . 27 Hygienic design requirements . . . . . . . . . . . . . . . . . . . . 27 Compliance with requirements derived from cGMP . . . . . . 27 TSE (BSE) compliance (ADI free - Animal Derived Ingredients) . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Industry Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 ASME BPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Ordering information . . . . . . . . . . . . . . . . . . . . . . . 27 Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Application packages . . . . . . . . . . . . . . . . . . . . . . . 28 Heartbeat Technology . . . . . . . . . . . . . . . . . . . . . . . . . 28 "Medium detection" operating mode . . . . . . . . . . . . . . . . 29 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Device-specific accessories . . . . . . . . . . . . . . . . . . . . . . 30 DeviceCare SFE100 . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 FieldCare SFE500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Device Viewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Field Xpert SMT70 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 SmartBlue app . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Standard documentation . . . . . . . . . . . . . . . . . . . . . . . . 31 Endress+Hauser Liquiphant FTL60 IO-Link Supplementary device-dependent documentation . . . . . . . 31 Registered trademarks . . . . . . . . . . . . . . . . . . . . . . 31 Endress+Hauser 3 Symbols List of abbreviations 4 Liquiphant FTL60 IO-Link About this document Safety symbols DANGER This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury. CAUTION This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in minor or medium injury. NOTICE This symbol contains information on procedures and other facts which do not result in personal injury. Tool symbols Open-ended wrench Communication-specific symbols Bluetooth®: Wireless data transmission between devices over a short distance. IO-Link: Communications system for connecting intelligent sensors and actuators to an automation system. In the IEC 61131-9 standard, IO-Link is standardized under the description "Single-drop digital communication interface for small sensors and actuators (SDCI)". Symbols for certain types of information Permitted: Procedures, processes or actions that are permitted. Forbidden: Procedures, processes or actions that are forbidden. Additional information: Reference to documentation: Reference to page: Series of steps: 1. , 2. , 3. Result of an individual step: Symbols in graphics Item numbers: 1, 2, 3 ... Series of steps: 1. , 2. , 3. Views: A, B, C, ... PN Nominal pressure MWP Maximum working pressure The maximum working pressure is indicated on the nameplate. Operating tool Endress+Hauser Liquiphant FTL60 IO-Link Graphic conventions The term "operating tool" is used in place of the following operating software: · FieldCare / DeviceCare, for operation via IO-Link communication and PC · SmartBlue app, for operation using an Android or iOS smartphone or tablet PLC Programmable logic controller (PLC) · Installation, explosion and electrical connection drawings are presented in simplified format · Devices, assemblies, components and dimensional drawings are presented in reduced-line format · Dimensional drawings are not to-scale representations; the dimensions indicated are rounded off to 2 decimal places · Unless otherwise described, flanges are presented with sealing surface form EN1092-1; ASME B16.5, RF. Measuring principle Measuring system Function and system design The sensor's tuning fork vibrates at its intrinsic frequency. As soon as the liquid covers the tuning fork, the vibration frequency decreases. The change in frequency causes the point level switch to switch. Point level detection Maximum or minimum detection for liquids in tanks or pipes in all industries. Suitable for leakage monitoring, pump dry-running protection or overfill prevention, for example. The point level switch differentiates between the "covered" and "not covered" conditions. Depending on the MIN (minimum detection) or MAX (maximum detection) modes, there are two possibilities in each case: OK status and demand mode. OK status · In MIN mode, the fork is covered, e.g. pump dry-running protection · In MAX mode, the fork is not covered, e.g. overfill prevention Demand mode · In MIN mode, the fork is not covered, e.g. pump dry-running protection · In MAX mode, the fork is covered, e.g. overfill prevention A complete measuring system comprises: 1 2 3 Communication and data processing Reliability 1 PLC (programmable logic controller) 2 IO-Link master 3 Device A0053220 · Digital communication protocol IO-Link, 3-wire · Bluetooth (optional) IT security Our warranty is valid only if the product is installed and used as described in the Operating Instructions. The product is equipped with security mechanisms to protect it against any inadvertent changes to the settings. IT security measures, which provide additional protection for the product and associated data transfer, must be implemented by the operators themselves in line with their security standards. Endress+Hauser 5 Liquiphant FTL60 IO-Link Device-specific IT security The device offers specific functions to support protective measures by the operator. These functions can be configured by the user and guarantee greater in-operation safety if used correctly. The user role can be changed with an access code (applies to operation via Bluetooth or FieldCare, DeviceCare or asset management tools (e.g. AMS, PDM). Access via Bluetooth® wireless technology Secure signal transmission via Bluetooth® wireless technology uses an encryption method tested by the Fraunhofer Institute. · Without the SmartBlue app, the device is not visible via Bluetooth® wireless technology. · Only one point-to-point connection is established between the device and a smartphone or tablet. · The Bluetooth® wireless technology interface can be disabled via local operation or via SmartBlue. Measured variable Measuring range Input Level (point level), MAX or MIN safety Depends on the installation location and the pipe extension ordered Maximum sensor length 1.5 m (5 ft) Output signal Switching capacity Signal on alarm for devices with current output Load Output · 2 outputs, configurable as switch output, analog output or IO-Link output · The current output offers a choice of three different operating modes: · 4 to 20.5 mA · NAMUR NE 43: 3.8 to 20.5 mA (factory setting) · US mode: 3.9 to 20.5 mA · Switch status ON: Ia 200 mA 1); switch status OFF: Ia <0.1 mA 2) · Switch cycles: >1 · 107 · Voltage drop PNP: 2 V · Overload protection: Automatic load testing of switching current; · Max. capacitive load: 1 µF at max. supply voltage (without resistive load) · Max. cycle duration: 0.5 s; min. ton: 40 µs · Periodic disconnection from protective circuit in the event of overcurrent (f = 1 Hz) Current output Signal on alarm in accordance with NAMUR recommendation NE 43. · Max. alarm: can be set from 21.5 to 23 mA · Min. alarm: <3.6 mA (factory setting) For the current output, the following applies: In order to guarantee sufficient terminal voltage, a maximum load resistance R L (including line resistance) must not be exceeded, depending on the supply voltage U of the supply unit. 1) If outputs "1 x PNP + 4 to 20 mA" are used at the same time, switch output OUT1 can be loaded with up to 100 mA load current over the entire temperature range. Up to 50 °C (122 °F) ambient temperature and up to 85 °C (185 °F) process temperature, the switching current may be up to 200 mA. If the "1 x PNP" or "2 x PNP" configuration is used, the switch outputs can be loaded in total with up to 200 mA over the entire temperature range. 2) Differing for switch output OUT2, for switch status OFF: Ia< 3.6 mA and Ua<2 V and for switch status ON: voltage drop PNP:2.5 V 6 Endress+Hauser Liquiphant FTL60 IO-Link Damping Switch output Protocol-specific data Terminal assignment R L max [W] 1022 587 152 2 RLmax £ U 12V 23 mA 0 10 20 12 1 30 U [V] 1 Power supply 12 to 30 V 2 RLmax maximum load resistance U Supply voltage A0052603 If load is too great: · Failure current is indicated and error message is displayed (indication: MIN alarm current) · Periodic checking to establish if it is possible to quit fault state A damping affects all continuous outputs. Factory setting: 1 s (can be configured from 0 to 999 s) Preset switching delay times can be ordered: · 0.5 s when the tuning fork is covered and 1.0 s when the tuning fork is uncovered (factory setting) · 0.25 s when the tuning fork is covered and 0.25 s when the tuning fork is uncovered · 1.5 s when the tuning fork is covered and 1.5 s when the tuning fork is uncovered · 5.0 s when the tuning fork is covered and 5.0 s when the tuning fork is uncovered The user can also set the switching delays for when the fork is covered and uncovered in the range from 1 to 60 seconds independently of one another. (Operation via Bluetooth or FieldCare, DeviceCare) IO-Link specification 1.1.3 Device type ID: 0x91 0xDF 0x01 Power supply 2-wire OUT 0.5A L+ 21 34 1 Supply voltage L+, brown wire (BN) 2 OUT (L-), white wire (WH) A0052660 Endress+Hauser 7 Liquiphant FTL60 IO-Link Available device plugs Supply voltage Power consumption Potential equalization Overvoltage protection 8 3-wire or 4-wire OUT2 0.5A L+ 21 34 OUT1 L 1 Supply voltage L+, brown wire (BN) 2 Switch or analog output (OUT2), white wire (WH) 3 Supply voltage L-, blue wire (BU) 4 Switching or IO-Link output (OUT1), black wire (BK) The functionality of output 1 and 2 can be configured. Connection examples A L+ 21 34 L B L+ 21 34 L A0052457 C L+ 21 34 L A 1 x PNP switch and analog output B 1 x PNP switch output C 2 x PNP switch output M12 plug A0052458 21 34 1 View of the connection on the device A0052661 For further information, see the "Device-specific accessories" section 12 to 30 VDC on a direct current power unit IO-Link communication is guaranteed only if the supply voltage is at least 18 V. The power unit must be tested to ensure it meets safety requirements (e.g. PELV, SELV, Class 2) and must comply with the relevant protocol specifications. A suitable circuit breaker should be provided for the device in accordance with IEC/EN61010-1. Protective circuits against reverse polarity, HF influences and overvoltage peaks are installed. Non-hazardous area: To meet device safety specifications according to the IEC/EN61010 standard, the installation must ensure that the maximum current is limited to 500 mA. If necessary, establish potential equalization using the process connection or the grounding clamp supplied by the customer. The device satisfies the IEC/DINEN 61326-1 product standard (Table 2 Industrial environment). Depending on the type of connection (DC supply, input/output line) different test levels according to Endress+Hauser Liquiphant FTL60 IO-Link IEC/DINEN 61326-1 against transient overvoltages are applied (IEC/DINEN 61000-4-5 Surge): test level for DC power supply lines and input/output lines: 1 000 V line to earth. Overvoltage protection category In accordance with IEC/DINEN 61010-1, the device is intended for use in networks with overvoltage protection category II. Reference operating conditions Take switch point into consideration Performance characteristics · As per IEC 62828-2 · Ambient temperature: +23 °C (+73 °F) · Process temperature: +23 °C (+73 °F) · Humidity j = constant, in the range: 5 to 80 % RH ± 5 % · Medium density (water): 1 g/cm³ (62.4 lb/ft³) · Medium viscosity: 1 mPas · Ambient pressure pA = constant, in the range: 860 to 1 060 mbar (12.47 to 15.37 psi) · Process pressure: atmospheric pressure/unpressurized · Sensor installation: vertically from above · Switch direction of sensor: uncovered to covered · Supply voltage: 24 V DC ±3 V DC The following are typical switch points, depending on the orientation of the point level switch. Water +23 °C (+73 °F) Minimum distance between the tuning fork and the tank wall or pipe wall: 10 mm (0.39 in) A B C ~13 (0.5) ~4 (0.16) ~12.5 (0.49) D D D Resolution Maximum measured error Hysteresis Non-repeatability Influence of the process temperature Influence of the process pressure 2 Typical switch points. Unit of measurement mm (in) A Installation from above B Installation from below C Installation from the side D Switch point A0037915 Current output: <1 µA At reference operating conditions: max. ± 1 mm (0.04 in) at switch point Typically 2.5 mm (0.1 in) 0.5 mm (0.02 in) The switch point moves from +1.4 to 2.6 mm (+0.06 to 0.1 in) in the temperature range of 50 to +150 °C (58 to +302 °F) The switch point moves from 0 to 2.6 mm (0 to 0.1 in) in the pressure range of 1 to +64 bar (14.5 to +928 psi) Endress+Hauser 9 Liquiphant FTL60 IO-Link Influence of the process medium density (at room temperature and normal pressure) C [in] [mm] 6 0.2 4 0.1 2 00 -0.1 -2 -4 -0.2 -6 -0.3 -8 0.5 31.2 B () B1 A () A1 1 62.4 3 Switch point deviation over density A Setting ()>0.7 g/cm³ (43.7 lb/ft³) A1 Reference operating condition = 1 g/cm³ (62.4 lb/ft³) B Setting ()>0.5 g/cm³ (31.21 lb/ft³) B1 Reference operating condition = 0.7 g/cm³ (43.7 lb/ft³) C Switch point deviation 1.5 93.6 2 [g/cm] [lb/³] 124.9 A0037669 Density setting · TCtyp., [mm/10 k] · >0.7 g/cm³ (43.7 lb/ft³): 0.2 · >0.5 g/cm³ (31.21 lb/ft³): 0.2 · Pressuretyp., [mm/10 bar] · >0.7 g/cm³ (43.7 lb/ft³): 0.3 · >0.5 g/cm³ (31.21 lb/ft³): 0.4 Response time Dynamic behavior of switch output 20 ms Dynamic behavior, current output · Dead time (t1): 3.5 ms maximum · Time constant T63 (t2): 10 ms maximum · Time constant T90 (t3): 24 ms maximum Warm-up time (according to IEC62828-4) The warm-up time indicates the time the sensor requires to reach its maximum accuracy or performance after the supply voltage is applied Warm-up time: 10 s Orientation Mounting · Any orientation for compact version or version with a tube length up to approx. 500 mm (19.7 in) · Vertical orientation from above for device with long pipe · Minimum distance between the tuning fork and the tank wall or pipe wall: 10 mm (0.39 in) 10 Endress+Hauser Liquiphant FTL60 IO-Link Installation instructions 4 Installation examples for a vessel, tank or pipe A0053113 Mounting instructions During installation, it is important to ensure that the sealing element used has an operating temperature that corresponds to the maximum temperature of the process. · Devices with CSA approval are intended for indoor use · Devices are suitable for use in wet environments in accordance with IEC/EN61010-1 Take viscosity into consideration Viscosity values · Low viscosity: <2 000 mPas · High viscosity: >2 000 to 10 000 mPas Low viscosity Low viscosity, e.g. water: <2 000 mPas It is permitted to position the tuning fork within the installation socket. > 50 (1.97) Endress+Hauser > 25 (0.98) 5 Installation example for low-viscosity liquids. Unit of measurement mm (in) High viscosity NOTICE Highly viscous liquids may cause switching delays. Make sure that the liquid can run off the tuning fork easily. Deburr the socket surface. High viscosity, e.g. viscous oils: 10 000 mPas The tuning fork must be located outside the installation socket! A0033297 11 Liquiphant FTL60 IO-Link > 40 (1.57) 6 Installation example for a highly viscous liquid. Unit of measurement mm (in) A0037348 Avoid buildup · Use short installation sockets to ensure that the tuning fork projects freely into the vessel · Leave sufficient distance between the buildup expected on the tank wall and the tuning fork 7 Installation examples for a highly viscous process medium Take clearance into consideration. Allow sufficient clearance outside the tank for mounting and electrical connection. A0033239 8 Take clearance into consideration. 12 A0053359 Endress+Hauser Liquiphant FTL60 IO-Link Aligning the tuning fork using the marking The tuning fork can be aligned using the marking in such a way that the medium drains off easily and buildup is avoided. Markings on process connection: Material specification, thread designation, circle, line or double line Installing the device in piping 316L/G1 9 Position of the tuning fork when installed horizontally in the vessel using the marking A0039125 · Flow velocity up to 5 m/s with a viscosity of 1 mPas and density of 1 g/cm³ (62.4 lb/ft³) (SGU). Check for correct functioning in the event of other process medium conditions. · The flow will not be significantly impeded if the tuning fork is correctly aligned and the marking is pointing in the direction of flow. · The marking is visible when installed. Special mounting instructions 10 Installation in pipes (take fork position and marking into consideration) A0034851 Vessel with heat insulation If process temperatures are high, the device should be incorporated in the usual vessel insulation system to prevent the electronics from heating as a result of thermal radiation or convection. The insulation in this case should not be higher than the neck of the device. 1 2 Endress+Hauser 11 Vessel with heat insulation (example) 1 Vessel insulation 2 Insulation max. up to the housing neck A0053115 Support the device Support the device in the event of severe dynamic load. Maximum lateral loading capacity of the pipe extensions and sensors: 75 Nm (55 lbf ft). 13 Liquiphant FTL60 IO-Link 12 Examples of support in the event of dynamic load A0053109 Weld-in adapter with leakage hole Weld in the weld-in adapter in such a way that the leakage hole is pointing downwards. This enables any leaks to be detected quickly. 316L 13 Weld-in adapter with leakage hole A0039230 Environment Ambient temperature range 40 to +85 °C (40 to +185 °F) The permitted ambient temperature is reduced at higher process temperatures. The following information only takes functional aspects into consideration. Additional restrictions may apply for certified device versions. 14 Endress+Hauser Liquiphant FTL60 IO-Link Storage temperature Operating height Climate class Degree of protection Pollution degree Vibration resistance Shock resistance Electromagnetic compatibility (EMC) Ta °F °C 185 85 P1 P2 104 40 32 0 -40 -40 P5 -40 0 80 -40 32 176 14 Ambient temperature Ta depending on the process temperature Tp P3 P4 150 °C Tp 302 °F A0053280 P Tp P1 40 °C (40 °F) P2 +80 °C (+176 °F) P3 +150 °C (+302 °F) P4 +150 °C (+302 °F) P5 40 °C (40 °F) Ta +85 °C (+185 °F) +85 °C (+185 °F) +40 °C (+77 °F) 40 °C (40 °F) 40 °C (40 °F) 40 to +85 °C (40 to +185 °F) Up to 5 000 m (16 404 ft) above sea level According to IEC60068-2-38 test Z/AD (relative humidity 4 to 100%). Test as per IEC60529 Edition 2.2 2013-08/ DINEN60529:2014-09 DINEN60529:2014-09 and NEMA 250-2014 For mounted M12 connecting cable: IP66/68/69, NEMA type 4X/6P /IP68,: (1.83mH2O for 24 h)) Pollution degree 2 according to IEC/EN61010-1 · Stochastic noise (random sweep) as per DINEN60068-2-64 Case 2/ IEC60068-2-64 Case 2 · Guaranteed for 5 to 2 000 Hz: 1.25 (m/s2)2/Hz, ~5 g · Test standard: DINEN60068-2-27 Case 2 · Shock resistance: 30 g (18 ms) in all 3 axes · Electromagnetic compatibility as per EN61326 series and NAMUR recommendation EMC (NE21) · Maximum deviation under the effect of disturbance: < 0.5% For more details refer to the EU Declaration of Conformity. Process Process temperature range 40 to +150 °C (40 to +302 °F) Pay attention to the pressure and temperature dependency. Endress+Hauser 15 Liquiphant FTL60 IO-Link Thermal shock Process pressure range Test pressure Density Viscosity Pressure tightness Solids contents 120 K/s Pressure specifications LWARNING The maximum pressure for the device depends on the lowest-rated component with regard to pressure (components are: process connection, optional mounted parts or accessories). Only operate the device within the specified limits for the components! MWP (maximum working pressure): The MWP is specified on the nameplate. This value refers to a reference temperature of +20 °C (+68 °F) and may be applied to the device for an unlimited time. Note temperature dependence of MWP. For flanges, refer to the following standards for the permitted pressure values at higher temperatures: EN 1092-1 (with regard to their stability/ temperature property, the materials 1.4435 and 1.4404 are grouped together under 13E0 in EN 1092-1, Tab. 18; the chemical composition of the two materials can be identical) ASME B 16.5a, (the latest version of the standard applies in each case). The Pressure Equipment Directive (2014/68/EU) uses the abbreviation "PS". The abbreviation "PS" corresponds to the MWP (maximum working pressure) of the device. MWP data that deviate from this are provided in the relevant sections of the Technical Information. · PN = 64 bar (928 psi): test pressure = 1.5·PN maximum100 bar (1 450 psi) depending on the selected process connection · Membrane burst pressure at 200 bar (2 900 psi) The device function is limited during the pressure test. Mechanical integrity is guaranteed up to 1.5 times the process nominal pressure PN. Liquids with density > 0.7 g/cm³ (43.7 lb/ft³) Setting >0.7 g/cm³ (43.7 lb/ft³), as supplied to the customer Liquids with density 0.5 g/cm³ (31.2 lb/ft³) Setting >0.5 g/cm³ (31.2 lb/ft³), can be ordered as preset value or configurable Liquids with density > 0.4 g/cm³ (25.0 lb/ft³) Setting >0.4 g/cm³ (25.0 lb/ft³), can be ordered as preset value or configurable For information on medium differentiation/density detection: Documentation Liquiphant density (FEL60D) with density computer FML621 (Endress+Hauser website www.endress.com Downloads) 10 000 mPas Up to vacuum In vacuum evaporation plants, select the 0.4 g/cm³ (25.0 lb/ft³)/ density setting. 5 mm (0.2 in) Design, dimensions Mechanical construction Device height The device height consists of the following components: · Housing with electronics module · Temperature spacer with/without pressure-tight feedthrough (second line of defense), optional · Compact version, pipe extension or short pipe version · Process connection The individual heights of the components can be found in the following sections: · Determine the height of the device and add the individual heights · Take the installation clearance into consideration (space that is needed to install the device) 16 Endress+Hauser Liquiphant FTL60 IO-Link 1 2 3 4 5 6 7 Dimensions 15 Product design 1 Housing with electronics module 2 Temperature spacer, pressure-tight feedthrough (second line of defense), optional 3 Process connection, e.g. clamp/Tri-Clamp 4 Process connection, e.g. thread 5 Compact probe version with tuning fork 6 Pipe extension probe with tuning fork 7 Short pipe version of probe with tuning fork Housing A0053358 45 (1.77) 95 (3.74) 115 (4.53) 54 (2.13) 12 (0.47) A0053970 Temperature spacer, pressure-tight feedthrough (optional) Provides sealed insulation for the vessel and a normal ambient temperature for the housing. Endress+Hauser 17 Liquiphant FTL60 IO-Link 1 A 1 Temperature spacer with/without pressure-tight feedthrough with maximum insulation length A 140 mm (5.51 in) A0053111 Product Configurator, feature "Sensor design": · Temperature spacer · Pressure-tight feedthrough (second line of defense) If the sensor is damaged, this protects the housing from vessel pressures up to 100 bar (1 450 psi). The "Pressure-tight feedthrough" version can only be selected in conjunction with the "Temperature spacer" option. Probe design Compact version Sensor length L: depends on process connection A For more details, see the "Process connections" section. L L L L 16 Probe design: Compact version, sensor length L A0042435 Short tube version Sensor length L: depends on process connection · Thread G 1 approx. 118 mm (4.65 in) · Ingold, flush-mounted tank connection, DIN11851 pipe union, Varivent, Clamp/Tri-Clamp approx. 115 mm (4.53 in) · Flush-mounted 1" (G1 welding boss from Endress+Hauser) approx. 104 mm (4.09 in) Pipe extension · Sensor lengths L: 148 to 1 500 mm (5.83 to 59.06 in) · Length tolerances L: <1 m (3.3 ft) = 5 mm (0.2 in), 1 to 3 m (3.3 to 9.8 ft) = 10 mm (0.39 in) A B C 21.5 ( 0.85) 21.5 ( 0.85) 21.5 ( 0.85) 17 Probe designs: pipe extension, short pipe (sensor length L). Unit of measurement mm (in) A Thread G1 B e.g. Clamp/Tri-Clamp, Varivent C Flush-mounted tank connection for installation in welding neck A0051989 18 Endress+Hauser Liquiphant FTL60 IO-Link Tuning fork 40 (1.57) 17.2 (0.68) 1.5 (0.06) 10 (0.39) 17 (0.67) Weight Materials Process connections Endress+Hauser 18 Tuning fork. Unit of measurement mm (in) A0038269 The weights of the individual components must be added together for the total weight. Housing including electronics module 0.2 kg (0.44 lb) Temperature spacer 0.6 kg (1.32 lb) Pressure-tight feedthrough 0.7 kg (1.54 lb) Pipe extension · 1 000 mm: 0.9 kg (1.98 lb) · 50 in: 1.15 kg (2.54 lb) Process connection See "Process connections" section Materials in contact with process Delta-ferrite content For the delta-ferrite content of the wetted parts, 1% can be guaranteed and certified (for welds 3%). Process connection and pipe extension 316L (1.4404 or 1.4435) Tuning fork 316L (1.4435) Seals Scope of delivery including seal · Ingold fitting, seal material: EPDM (in compliance with FDA, USP Class VI) · Flush-mounted tank connection for installation in welding neck, seal material: silicone Materials not in contact with process · Housing: 316L (1.4404) · Display: Polycarbonate · Device plug: For more information, see section on "Power supply". Process connection, sealing surface · Flange ASME B16.5, RF · Flange EN1092-1, A · Flange EN1092-1, B1 · Thread ISO228, G · Ingold · Flush-mounted tank connection · DIN11851 pipe union · DIN11864-1 pipe union 19 · DRD · SMS1145 pipe union · Varivent (Varinline) · Clamp/Tri-Clamp Height of process connection A B Liquiphant FTL60 IO-Link C 18 (0.71) 18 (0.71) 37 (1.46) 19 Maximum height specification for the process connections. Unit of measurement mm (in) A Process connection with threaded connection B For example: Clamp/Tri-Clamp, Varivent C Flush-mounted tank connection for installation in welding neck A0052399 Thread ISO228 G ¾ for installation in weld-in adapter G ¾ with defined thread start for flush mounting in weld-in adapter · Only for sensor design: compact version · Material: 316L · Pressure rating, temperature: 40 bar (580 psi), +100 °C (+212 °F) · Pressure rating, temperature: 25 bar (363 psi), +150 °C (+302 °F) · Weight: 0.2 kg (0.44 lb) · Accessories: weld-in adapter, optionally available as "Accessory enclosed" A seal is not included in the delivery. The maximum temperature and maximum pressure depend on the clamping ring and sealing element used (according to the process connection design). The lowest value applies in each case. 66.5 (2.62) 32 50.5 (1.99) 20 Thread ISO228 G¾. Unit of measurement mm (in) A0035549 Thread ISO228 G 1 for installation in weld-in adapter G 1 with defined thread start, comprising sealing surface for flush mounting in weld-in adapter · Material: 316L · Pressure rating, temperature: 40 bar (580 psi), +100 °C (+212 °F) · Pressure rating, temperature: 25 bar (363 psi), +150 °C (+302 °F) · Weight: 0.33 kg (0.73 lb) · Accessories: weld-in adapter, optionally available as "Accessory enclosed" A seal is not included in the delivery. The maximum temperature and maximum pressure depend on the clamping ring and sealing element used (according to the process connection design). The lowest value applies in each case. 20 Endress+Hauser Liquiphant FTL60 IO-Link 80 (3.15) 41 61.3 (2.41) 21 Thread ISO228 G1. Unit of measurement mm (in) Ingold fitting Ingold fitting 25 x 46 mm (2.52 in) · Material: 316L · Pressure rating: 16 bar (232 psi) · Temperature: 150 °C (302 °F) · Weight: 0.2 kg (0.44 lb) · Scope of delivery: cap-nut G1¼, seal 46 (1.81) 51.5 (2.03) 22 Ingold fitting 25 x 46 mm (2.52 in). Unit of measurement mm (in) Flush-mounted tank connection for installation in weld-in adapter · Material: 316L · Pressure rating, temperature: 40 bar (580 psi), +100 °C (+212 °F) · Pressure rating, temperature: 25 bar (363 psi), 140 °C (284 °F) · Weight: 0.44 kg (0.97 lb) · Accessories: weld-in adapter, optionally available as "Accessory enclosed" · Scope of delivery: cap-nut, seal 55.5 (2.19) Endress+Hauser 23 Flush-mounted tank connection. Unit of measurement mm (in) DIN11851 pipe union DN32 PN25 · Material: 316L · Slotted nut · Pressure rating, temperature: 40 bar (580 psi), +100 °C (+212 °F) · Pressure rating, temperature: 25 bar (363 psi), 140 °C (284 °F) · Weight: 0.3 kg (0.66 lb) DN40 PN25 · Material: 316L · Slotted nut · Pressure rating, temperature: 40 bar (580 psi), +100 °C (+212 °F) · Pressure rating, temperature: 25 bar (363 psi), 140 °C (284 °F) · Weight: 0.35 kg (0.77 lb) A0035551 A0051991 A0051993 21 Liquiphant FTL60 IO-Link DN50 PN25 · Material: 316L · Slotted nut · Pressure rating: 25 bar (363 psi) · Temperature: 140 °C (284 °F) · Weight: 0.47 kg (1.04 lb) A seal is not included in the delivery. The maximum temperature and maximum pressure depend on the clamping ring and sealing element used (according to the process connection design). The lowest value applies in each case. 66.5 (2.62) 24 DIN11851 pipe union. Unit of measurement mm (in) A0051995 DIN11864-1 pipe union DIN11864-1 A DN50 pipe DIN11850 · Material: 316L · Slotted nut · Pressure rating: 25 bar (363 psi) · Temperature: 140 °C (284 °F) · Weight: 0.47 kg (1.04 lb) A seal is not included in the delivery. The maximum temperature and maximum pressure depend on the clamping ring and sealing element used (according to the process connection design). The lowest value applies in each case. 66.5 (2.62) 25 DIN11864-1 pipe union. Unit of measurement mm (in) A0052381 DRD DRD 65 mm (2.56 in) · Material: 316L · Pressure rating, temperature: 40 bar (580 psi), +100 °C (+212 °F) · Pressure rating, temperature: 25 bar (363 psi), 140 °C (284 °F) · Weight: 0.43 kg (0.95 lb) · Accessories: welding flange with PTFE flat seal, optionally available as "Accessory enclosed" A seal is not included in the delivery. The maximum temperature and maximum pressure depend on the clamping ring and sealing element used (according to the process connection design). The lowest value applies in each case. 22 Endress+Hauser Liquiphant FTL60 IO-Link 66.5 (2.62) 26 DRD. Unit of measurement mm (in) A0051992 SMS1145 pipe union SMS 2" PN25 · Material: 316L · Pressure rating: 25 bar (363 psi) · Temperature: 140 °C (284 °F) · With cap-nut · Weight: 0.33 kg (0.72 lb) A seal is not included in the delivery. The maximum temperature and maximum pressure depend on the clamping ring and sealing element used (according to the process connection design). The lowest value applies in each case. 66.5 (2.62) 27 SMS1145 pipe union. Unit of measurement mm (in) A0051994 Varivent (Varinline) Varivent F pipe DN25-32 PN40 · Material: 316L · Pressure rating: 25 bar (363 psi) · Temperature: 150 °C (302 °F) · Weight: 0.36 kg (0.79 lb) A seal is not included in the delivery. The maximum temperature and maximum pressure depend on the clamping ring and sealing element used (according to the process connection design). The lowest value applies in each case. 56.5 (2.22) ø50 (1.97) 28 Varivent F pipe DN25-32 PN40. Unit of measurement mm (in) A0052749 Endress+Hauser 23 Liquiphant FTL60 IO-Link Varivent N pipe DN65-162 PN25 · Material: 316L · Pressure rating: 25 bar (363 psi) · Temperature: 150 °C (302 °F) Suitable for GEA Tuchenhagen · Weight: 0.72 kg (1.59 lb) A seal is not included in the delivery. The maximum temperature and maximum pressure depend on the clamping ring and sealing element used (according to the process connection design). The lowest value applies in each case. 56.5 (2.22) ø68 (2.68) 29 Varivent N pipe DN65-162 PN25. Unit of measurement mm (in) A0051996 Tri-Clamp ISO 2852 DN25-38 (1 to 1½"), DIN 32676 DN25-40 · Material: 316L · Pressure rating: 25 bar (363 psi) · Temperature: 150 °C (302 °F) · Weight: 0.3 kg (0.66 lb) ISO 2852 DN40-51 (2"), DIN 32676 DN50 · Material: 316L · Pressure rating: 25 bar (363 psi) · Temperature: 150 °C (302 °F) · Weight: 0.3 kg (0.66 lb) The Tri-Clamp connection is compatible with NA Connect. A seal is not included in the delivery. The maximum temperature and maximum pressure depend on the clamping ring and sealing element used (according to the process connection design). The lowest value applies in each case. 66.5 (2.62) 66.5 (2.62) 50.5 (1.99) 64 (2.52) 30 Tri-Clamp 1 to 1½". Unit of measurement mm (in) A0035555 A0037671 31 Tri-Clamp 2". Unit of measurement mm (in) 24 Endress+Hauser Liquiphant FTL60 IO-Link Flanges 66.5 (2.62) Surface roughness LED indicator Endress+Hauser 32 Example with flange. Unit of measurement mm (in) ASME B16.5 flanges, RF Pressure rating Cl.150 Type NPS 2" Material 316/316L A0035554 Weight 2.4 kg (5.29 lb) EN flanges EN 1092-1, A Pressure rating PN25/40 PN25/40 Type DN25 DN50 Material 316L (1.4404) 316L (1.4404) Weight 1.3 kg (2.87 lb) 3.2 kg (7.06 lb) EN flanges EN 1092-1, B1 Pressure rating PN25/40 PN25/40 Type DN25 DN50 Material 316L (1.4404) 316L (1.4404) Weight 1.4 kg (3.09 lb) 3.2 kg (7.06 lb) · Housing: Ra <1.6 µm (63 µin), electropolished · Parts in contact with process: Ra <1.5 µm (59.1 µin) CoC ASME BPE Optional: · Ra<0.3 µm (12 µin) mechanically polished (3-A, EHEDG) · Ra<0.38 µm (15 µin) electropolished, (3-A, EHEDG, CoC ASME BPE) In this version, the wetted parts are made of 316L (1.4435) in accordance with BN2 (delta-ferrite content < 1%) Display and user interface The device is optionally available with Bluetooth® wireless technology. Functions: · Display of the operating status (operation or fault) · Display of Bluetooth connection, locking status and function · Easy setup of the following functions with one button: · Bluetooth On/Off · Locking On/Off · Trigger proof test or functional test 25 Liquiphant FTL60 IO-Link Remote operation 1 2 3 4 5 E 1 Operating status LED 2 Operating key "E" 3 Bluetooth LED 4 Trigger proof test or functional test LED 5 Keypad lock LED Proof-test function For proof testing in safety instrumented systems according to WHG The operating status LED shows the simulation status generated by the proof test. Via IO-Link or Bluetooth A0052426 6 2 4 1 3 5 33 Options for remote operation via IO-Link 1 PLC (programmable logic controller) 2 IO-Link master 3 Computer with operating tool e.g. DeviceCare/FieldCare) 4 FieldPort SFP20 5 Field Xpert SMT70/SMT77 or computer with operating tool (e.g. DeviceCare/FieldCare) 6 Transmitter A0053130 Operation via Bluetooth® wireless technology (optional) Prerequisite · Device with Bluetooth order option · Smartphone or tablet with Endress+Hauser SmartBlue app or PC with DeviceCare from version 1.07.07 or FieldXpert SMT70/SMT77 The connection has a range of up to 25 m (82 ft). The range can vary depending on environmental conditions such as attachments, walls or ceilings. The operating keys on the display are locked as soon as the device is connected via Bluetooth. 26 Endress+Hauser Liquiphant FTL60 IO-Link System integration Supported operating tools · IO-Link V1.1. · Smart Sensor Profile type 4.3 · SIO: Yes · Speed: COM2; 38.4 kBaud · Process data width: See Operating Instructions · Data storage: Yes · Block configuration: Yes Smartphone or tablet with Endress+Hauser SmartBlue app, DeviceCare from version 1.07.07, FieldCare. Hygienic design requirements Compliance with requirements derived from cGMP TSE (BSE) compliance (ADI free - Animal Derived Ingredients) Industry Canada ASME BPE Certificates and approvals Current certificates and approvals for the product are available at www.endress.com on the relevant product page: 1. Select the product using the filters and search field. 2. Open the product page. 3. Select Downloads. Other certificates and approvals for the product are available under https://www.endress.com-> Downloads. · Notes on installation and certification in accordance with 3-A and EHEDG: SD02503F document "Hygienic approvals" · Information on 3-A and EHEDG-certified adapters: TI00426F document "Weld-in adapters, process adapters and flanges" · 3-A and EHEDG-certified versions of the sensor are suitable for Cleaning-in-Place (CIP) and Sterilization-in-Place (SIP) without removing them from the plant. This means that the sensor does not need to be removed during cleaning. The maximum permitted pressure and temperature values for sensor and adapter must not be exceeded (see notes in this TI). · ASME BPE cGMP is suitable for wetted parts: · The certificate is only available in English · Materials of construction · ADI-free based upon EMA/410/01 Rev.3 (TSE/BSE compliant) · Polishing and surface finish · Material/compound compliance table: USP, FDA As the manufacturer, Endress+Hauser states: · That the parts of this product in contact with the process are not made from materials derived from animals or · at least comply with the requirements of guidelines outlined in EMA/410/01 rev. 3 (TSE (BSE) compliance). CNR-Gen Section 7.1.3 The measuring system meets the requirements of the ASME BPE standard (Bioprocessing Equipment). Ordering information Detailed ordering information is available from your nearest sales organization www.addresses.endress.com or in the Product Configurator at www.endress.com: 1. Select the product using the filters and search field. 2. Open the product page. Endress+Hauser 27 Identification Liquiphant FTL60 IO-Link 3. Select Configuration. Product Configurator - the tool for individual product configuration · Up-to-the-minute configuration data · Depending on the device: Direct input of measuring point-specific information such as measuring range or operating language · Automatic verification of exclusion criteria · Automatic creation of the order code and its breakdown in PDF or Excel output format · Ability to order directly in the Endress+Hauser Online Shop Measuring point (TAG) The device can be ordered with a tag name. Location of tag name Select in the additional specification: · Stainless steel wired-on tag plate · Paper adhesive label · Tag provided by the customer · Nameplate · IEC 61406 stainless steel tag · IEC 61406 stainless steel + NFC tag · IEC 61406 stainless steel, stainless steel tag · IEC61406 stainless steel + NFC, stainless steel · IEC61406 stainless steel tag, plate provided · IEC61406 stainless steel + NFC, plate provided Definition of tag name Specify in the additional specification: 3 lines of maximum 18 characters each The specified tag name appears on the selected plate. Visualization in SmartBlue app The first 32 characters of the tag name The tag name can always be changed specifically for the measuring point via Bluetooth. Display on the nameplate The first 16 characters of the tag name Display in electronic nameplate (ENP) The first 32 characters of the tag name For details, see document SD03128P Heartbeat Technology Application packages The application package can be ordered together with the device or can be activated subsequently with an activation code. Detailed information on the relevant order code is available from the website www.endress.com or from the Endress +Hauser Sales Center. Heartbeat Technology offers diagnostic functionality through continuous self-monitoring, the transmission of additional measured variables to an external Condition Monitoring system and the in situ verification of devices in the application. Heartbeat Diagnostics Continuous self-monitoring of the device. Diagnostic messages output to: · the onsite display · an asset management system (e.g. FieldCare or DeviceCare) · an automation system (e.g. PLC) 28 Endress+Hauser Liquiphant FTL60 IO-Link "Medium detection" operating mode Heartbeat Verification · Monitoring of the installed device without interrupting the process, including a verification report · Clear measuring point assessment (pass/fail) with high total test coverage as part of the manufacturer's specification · Can be used to document normative requirements · Meets the requirements for measurement traceability in accordance with ISO9001 (ISO9001:2015 Section 7.1.5.2) The verification report can be generated via Bluetooth. Heartbeat Monitoring · Continuously provides device and/or process data for an external system. Analysis of these data provides a basis for process optimization and predictive maintenance. · Loop diagnostics wizard: Detection of elevated measuring circuit resistance values or declining power supply · Process window wizard: Two frequency limits for monitoring the upper and lower range of the oscillation frequency (can be defined independently of one another). Changes in the process can be identified, e.g. corrosion or buildup. · Safety mode wizard: The device can be write-protected via the software using this wizard. The safety-related parameters must be confirmed in the wizard. Detailed description See Special Documentation for SD Heartbeat Technology. Default setting of operating mode (as-delivered state): point level detection of liquids. This setting covers most applications. In addition, the following operating modes can be selected in combination with the Heartbeat package: · Foam detection · Foam suppression Foam detection Area of application: point level detection in liquids with foam generation. The device detects the foam and switches as soon as the tuning fork is immersed in the foam or when the fork is uncovered. Application in accordance with the WHG (German Water Resources Act) is not possible in this operating mode. Detection of light foams such as: · Beer foam · Milk foam Influence on switching behavior: · Particularly large air bubbles in the foam · Significantly reduced liquid content in the foam · Change in the properties of the foam during operation Foam suppression Area of application: point level detection in liquids with foam generation. The device only switches when immersed in a homogeneous liquid. The device does not react to the foam in this setting (is suppressed). Application in accordance with the WHG (German Water Resources Act) is not possible in this operating mode. Endress+Hauser 29 Liquiphant FTL60 IO-Link Device-specific accessories Accessories Accessories currently available for the product can be selected via the Product Configurator at www.endress.com: 1. Select the product using the filters and search field. 2. Open the product page. 3. Select Spare parts & Accessories. M12 socket M12 socket, straight · Material: Body: PA; union nut: stainless steel; seal: EPDM · Degree of protection (fully locked): IP69 · Order number: 71638191 M12 socket, elbowed · Material: Body: PA; union nut: stainless steel; seal: EPDM · Degree of protection (fully locked): IP69 · Order number: 71638253 Cables Cable 4 x 0.34 mm2 (20 AWG) with M12 socket, elbowed, screw plug, length 5 m (16 ft) · Material: body: TPU; union nut: nickel-plated die-cast zinc; cable: PVC · Degree of protection (fully locked): IP68/69 · Order number: 52010285 · Wire colors · 1 = BN = brown · 2 = WT = white · 3 = BU = blue · 4 = BK = black Welding neck, process adapter and flange For details, refer to TI00426F/00/EN "Weld-in adapters, process adapters and flanges". DeviceCare SFE100 Configuration tool for IO-Link, HART, PROFIBUS and FOUNDATION Fieldbusfield devices DeviceCare is available for download free of charge at www.software-products.endress.com. You need to register in the Endress+Hauser software portal to download the application. Technical Information TI01134S FieldCare SFE500 FDT-based plant asset management tool It can configure all intelligent field units in your system and helps you manage them. By using the status information, it is also a simple but effective way of checking their status and condition. Technical Information TI00028S Device Viewer Field Xpert SMT70 All the spare parts for the device, along with the order code, are listed in the Device Viewer (www.endress.com/deviceviewer). Universal, high-performance tablet PC for device configuration in Ex Zone 2 and non-Ex areas For details, see "Technical Information" TI01342S SmartBlue app Mobile app for easy configuration of devices on site via Bluetooth wireless technology 30 Endress+Hauser Liquiphant FTL60 IO-Link Standard documentation Supplementary devicedependent documentation Documentation For an overview of the scope of the associated Technical Documentation, refer to the following: · Device Viewer (www.endress.com/deviceviewer): Enter the serial number from the nameplate · Endress+Hauser Operations app: Enter serial number from nameplate or scan matrix code on nameplate. Document type: Operating Instructions (BA) Installation and initial commissioning contains all the functions in the operating menu that are needed for a routine measuring task. Functions beyond this scope are not included. Document type: Description of Device Parameters (GP) The document is part of the Operating Instructions and serves as a reference for parameters, providing a detailed explanation of each individual parameter of the operating menu. Document type: Brief Operating Instructions (KA) Quick guide to the first measured value includes all essential information from incoming acceptance to electrical connection. Document type: Safety Instructions, certificates Depending on the approval, safety instructions are supplied with the device, e.g. XA. This documentation is an integral part of the Operating Instructions. Information on the Safety Instructions (XA) that are relevant for the device is provided on the nameplate. Additional documents are supplied depending on the device version ordered: Always comply strictly with the instructions in the supplementary documentation. The supplementary documentation is an integral part of the device documentation. Registered trademarks Apple® Apple, the Apple logo, iPhone, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Android® Android, Google Play and the Google Play logo are trademarks of Google Inc. Bluetooth® The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by Endress+Hauser is under license. Other trademarks and trade names are those of their respective owners. ® Is a registered trademark. It may only be used in conjunction with products and services by members of the IO-Link Community or by non-members who hold an appropriate license. For more detailed information on its use, refer to the rules of the IO-Link Community at: www.io.link.com. Endress+Hauser 31 *71645388* 71645388 www.addresses.endress.com