Cecotec Ready Warm Series Electric Radiator
Model Numbers: 800, 1200, 1800, 2000, 2500 Thermal
Fin Electric Radiator
Important Usage Note
This product is not suitable for primary heating purposes. This product is only suitable for well insulated spaces or occasional use.
1. Parts and Components
The following components are part of the electric radiator:
- 1. Control panel
- 2. Power switch
- 3. Stands (for floor mounting)
- 4. Temperature sensor
- 5. Wall supports (for wall mounting)
- 6. Wall support accessory
- 7. Remote control
- 8. ON/OFF button
- 9. Display
- 10. Schedule button
- 11. Up/Increase button (▲)
- 12. Down/Decrease button (▼)
- 13. Day mode indicator/button (☀️)
- 14. Night mode indicator/button (?)
- 15. Anti-frost mode indicator/button (❄️)
- 16. Lock indicator/button (?)
- 17. Mode button
- 18. Monday to Sunday indicator
- 19. Power indicator (?)
- 20. Hour - Temp display
- 21. Hour display
Diagram Description: The diagram shows the main unit with numbered parts, the control panel with buttons and display, stands for floor placement, wall supports, and the remote control.
2. Safety Instructions
Please read these instructions thoroughly before using the appliance. Keep this instruction manual for future reference or new users.
- Ensure the mains voltage matches the appliance's rating label and the outlet is grounded.
- This appliance is for household use only. Do not use for industrial or commercial purposes.
- Regularly check the power cord for visible damage. If damaged, contact Cecotec Technical Support for replacement to avoid danger.
- Do not cover the device to prevent overheating.
- When installing on a bathroom wall, ensure it is placed at a distance where no person in the shower or bath can reach it.
- Do not use the device directly on the floor without installing the legs.
- Keep the appliance away from heat sources, flammable substances, wet surfaces, or areas where it could fall into water or come into contact with liquids. Do not operate outdoors.
- Do not place the appliance immediately below a power socket.
- Allow the device to operate at maximum temperature for 2-3 hours in a ventilated area to eliminate manufacturing residues.
- The product surface gets hot during operation. Avoid skin contact and use the handle to move it.
- Always use the appliance with fins in an upright position.
- Keep packaging materials out of reach of children.
- The appliance is not intended for use by children under 8 years old. Children over 8 may use it under continuous supervision.
- Children aged 8 and above, and persons with reduced physical, sensory, or mental capabilities, or lack of experience/knowledge, may use the appliance if supervised or instructed on safe usage and potential hazards. Children should not play with the appliance.
- Supervise young children to ensure they do not play with the appliance. Close supervision is necessary when the appliance is used by or near children.
3. Product Assembly
Floor Assembly
Place the stands on the bottom part of the device, one on each side, and screw them in securely.
Wall Assembly
- Ensure the appliance is at least 20 cm from any obstacles (walls, shelves, floor) before installation.
- Drill two holes on the wall with a 140 mm distance between them.
- Attach the wall supports (5) to the wall using the provided studs and screws. Ensure the smaller-diameter side of the supports is hung from the wall.
- Screw the wall-support accessory (6) onto the two holes on the back-bottom part of the device. Ensure the side with one hole is against the wall.
- Hang the appliance from the supports.
- Once hung, mark the free hole of the wall-support accessory (6).
- Remove the appliance, drill a hole at the marked spot, and insert the corresponding stud.
- Finally, hang the appliance on the brackets and screw the mounting plate to the wall.
Diagram Description: The diagrams show the wall supports (part 5) and the wall-support accessory (part 6), illustrating how they attach to the wall and the appliance.
4. Operation
Automatic Lock
The control panel buttons will lock if no button is pressed for 1 minute during operation. To unlock, press and hold the (-) button for 3 seconds.
Manual Operation
The electric radiator can be operated manually or programmed.
Manual Mode
There are 3 operating modes:
- ☀️ Day mode: Temperature can be set from 5 to 35 °C.
- ? Night mode: Temperature can be set from 5 to 35 °C.
- ❄️ Anti-frost mode: Temperature can be set from 5 to 15 °C.
Note: For the device to operate, the set temperature must always be higher than the room temperature. The display shows the temperature near the device, not the exact room temperature. When setting the temperature, select a few degrees higher than desired.
Turning the Device On
- Connect the device to power and turn on the power switch (2). The control panel will flash, and the "°C" symbol, room temperature, and power indicator (?) will light up. If the power indicator does not light up, press it.
- Select the desired operating mode (Day ☀️, Night ?, or Anti-frost ❄️) by pressing the corresponding button. The display will show the selected mode.
- Use the + and – buttons to set the desired temperature for the selected mode. The "°C" icon will blink while setting.
- Once set, the display will show the room temperature again.
- Repeat for other modes.
- Use the on/off button to turn the radiator on and off.
Thermostat
When the device reaches the set temperature, it will automatically switch off, and the thermostat icon (?) will turn off. When the room temperature falls below the set temperature, the device will automatically turn back on, and the thermostat icon (?) will light up again.
Note: The thermostat icon (?) may blink when the device is about to turn on or off. Set temperatures are saved even if the device is disconnected or turned off.
Reset
To reset the device while connected to power and the switch is on: ensure the device is unlocked (or unlock it with the remote control) and press the power button (-) for 3 seconds, or switch off from the power switch (2).
5. Programming
3 Operating Modes
- ☀️ Day mode: Temperature can be set from 5 to 35 °C.
- ? Night mode: Temperature can be set from 5 to 35 °C.
- ❄️ Anti-frost mode: Temperature can be set from 5 to 15 °C.
Manually set temperatures will apply to modes during programmed operations.
Setting Current Time and Day
- Press and hold the "PROG" button until "00:00" appears on the display.
- Hour digits will blink. Use + and – buttons to set the hour, then press "PROG" to save.
- Minute digits will blink. Use + and – buttons to set the minutes, then press "PROG" to save.
- The display will show the week calendar (1-7, Monday-Sunday). Select the current day using + and – buttons, then press "PROG" to save.
Setting Weekly Schedule
- The display will show the first 2 bars for the first time period (00:00 – 1:00) blinking, indicating Monday (1).
- Press the desired mode button (Day ☀️, Night ?, or Anti-frost ❄️) for the selected time interval. The corresponding bar will blink.
- Once the first period is scheduled, press "+" and the next time period's bars will blink.
- Repeat for all 24 hours of the day.
- When a day is scheduled, press "PROG" to finish that day and repeat for all 7 days of the week.
- After scheduling the whole week, press "PROG" to save settings and operate in the programmed mode.
WARNING: If the device is disconnected from the power supply, schedule settings are saved, but the current day and time will reset.
Resetting Current Time and Day
To reset: long-press "PROG" until "00:00" appears. Use + and – to set the hour, press "PROG", use + and – to set minutes, press "PROG" to save.
Adjusting Temperature Under Programmed Mode
During programmed operation, press the remote control's ON button twice, then use + and – to select the desired temperature. This temperature will be saved for future operations in that mode.
6. Remote Control
The remote control requires 1 x CR2025 battery (included).
- Remove the protection label from the battery compartment. Open the battery cover if necessary.
- The radiator can be scheduled using the remote control following the same steps as on the device panel.
7. Cleaning and Maintenance
- Turn off, unplug the appliance, and allow it to cool down before cleaning or repairing.
- Use a soft, dry cloth to clean the exterior parts.
- Do not use chemical, abrasive cleaning agents, or scouring pads, as they may damage the surface.
8. Technical Specifications
Model: Ready Warm 800 Thermal (Product Reference: 05330)
600 W, 220-240 V, 50/60 Hz | Made in China | Designed in Spain
Item | Symbol | Value | Unit | Type of heat input, for electric storage local space heaters only (select one) |
---|---|---|---|---|
Heat output | ||||
Nominal heat output | Pnom | 0.60 | kW | Manual heat charge control, with integrated thermostat |
Minimum heat output (indicative) | Pmin | 0.60 | kW | Manual heat charge control with room and/or outdoor temperature feedback |
Maximum continuous heat output | Pmax,c | 0.60 | kW | Electronic heat charge control with room and/or outdoor temperature feedback |
Auxiliary electricity consumption | ||||
Fan assisted heat output | ||||
Type of heat output/room temperature control (select one) | ||||
At nominal heat output | elmax | N/A | kW | Single stage heat output and no room temperature control |
At minimum heat output | elmin | N/A | kW | Two or more manual stages, no room temperature control |
In standby mode | elSB | 0.00094 | kW | With mechanic thermostat room temperature control |
With electronic room temperature control | ||||
Electronic room temperature control plus day timer | ||||
Electronic room temperature control plus week timer | ||||
Other control options (multiple selections possible) | ||||
Room temperature control, with presence detection | ||||
Room temperature control, with open window detection | ||||
With distance control option | ||||
With adaptive start control | ||||
With working time limitation | ||||
With black bulb sensor |
Model: Ready Warm 1200 Thermal (Product Reference: 05331)
900 W, 220-240 V, 50/60 Hz | Made in China | Designed in Spain
Item | Symbol | Value | Unit | Type of heat input, for electric storage local space heaters only (select one) |
---|---|---|---|---|
Heat output | ||||
Nominal heat output | Pnom | 0.90 | kW | Manual heat charge control, with integrated thermostat |
Minimum heat output (indicative) | Pmin | 0.90 | kW | Manual heat charge control with room and/or outdoor temperature feedback |
Maximum continuous heat output | Pmax,c | 0.90 | kW | Electronic heat charge control with room and/or outdoor temperature feedback |
Auxiliary electricity consumption | ||||
Fan assisted heat output | ||||
Type of heat output/room temperature control (select one) | ||||
At nominal heat output | elmax | N/A | kW | Single stage heat output and no room temperature control |
At minimum heat output | elmin | N/A | kW | Two or more manual stages, no room temperature control |
In standby mode | elSB | 0.00094 | kW | With mechanic thermostat room temperature control |
With electronic room temperature control | ||||
Electronic room temperature control plus day timer | ||||
Electronic room temperature control plus week timer | ||||
Other control options (multiple selections possible) | ||||
Room temperature control, with presence detection | ||||
Room temperature control, with open window detection | ||||
With distance control option | ||||
With adaptive start control | ||||
With working time limitation | ||||
With black bulb sensor |
Model: Ready Warm 1800 Thermal (Product Reference: 05332)
1200 W, 220-240 V, 50/60 Hz | Made in China | Designed in Spain
Item | Symbol | Value | Unit | Type of heat input, for electric storage local space heaters only (select one) |
---|---|---|---|---|
Heat output | ||||
Nominal heat output | Pnom | 1.2 | kW | Manual heat charge control, with integrated thermostat |
Minimum heat output (indicative) | Pmin | 1.2 | kW | Manual heat charge control with room and/or outdoor temperature feedback |
Maximum continuous heat output | Pmax,c | 1.2 | kW | Electronic heat charge control with room and/or outdoor temperature feedback |
Auxiliary electricity consumption | ||||
Fan assisted heat output | ||||
Type of heat output/room temperature control (select one) | ||||
At nominal heat output | elmax | N/A | kW | Single stage heat output and no room temperature control |
At minimum heat output | elmin | N/A | kW | Two or more manual stages, no room temperature control |
In standby mode | elSB | 0.00094 | kW | With mechanic thermostat room temperature control |
With electronic room temperature control | ||||
Electronic room temperature control plus day timer | ||||
Electronic room temperature control plus week timer | ||||
Other control options (multiple selections possible) | ||||
Room temperature control, with presence detection | ||||
Room temperature control, with open window detection | ||||
With distance control option | ||||
With adaptive start control | ||||
With working time limitation | ||||
With black bulb sensor |
Model: Ready Warm 2000 Thermal (Product Reference: 05333)
1500 W, 220-240 V, 50/60 Hz | Made in China | Designed in Spain
Item | Symbol | Value | Unit | Type of heat input, for electric storage local space heaters only (select one) |
---|---|---|---|---|
Heat output | ||||
Nominal heat output | Pnom | 1.5 | kW | Manual heat charge control, with integrated thermostat |
Minimum heat output (indicative) | Pmin | 1.5 | kW | Manual heat charge control with room and/or outdoor temperature feedback |
Maximum continuous heat output | Pmax,c | 1.5 | kW | Electronic heat charge control with room and/or outdoor temperature feedback |
Auxiliary electricity consumption | ||||
Fan assisted heat output | ||||
Type of heat output/room temperature control (select one) | ||||
At nominal heat output | elmax | N/A | kW | Single stage heat output and no room temperature control |
At minimum heat output | elmin | N/A | kW | Two or more manual stages, no room temperature control |
In standby mode | elSB | 0.00094 | kW | With mechanic thermostat room temperature control |
With electronic room temperature control | ||||
Electronic room temperature control plus day timer | ||||
Electronic room temperature control plus week timer | ||||
Other control options (multiple selections possible) | ||||
Room temperature control, with presence detection | ||||
Room temperature control, with open window detection | ||||
With distance control option | ||||
With adaptive start control | ||||
With working time limitation | ||||
With black bulb sensor |
Model: Ready Warm 2500 Thermal (Product Reference: 05334)
1800 W, 220-240 V, 50/60 Hz | Made in China | Designed in Spain
Item | Symbol | Value | Unit | Type of heat input, for electric storage local space heaters only (select one) |
---|---|---|---|---|
Heat output | ||||
Nominal heat output | Pnom | 1.8 | kW | Manual heat charge control, with integrated thermostat |
Minimum heat output (indicative) | Pmin | 1.8 | kW | Manual heat charge control with room and/or outdoor temperature feedback |
Maximum continuous heat output | Pmax,c | 1.8 | kW | Electronic heat charge control with room and/or outdoor temperature feedback |
Auxiliary electricity consumption | ||||
Fan assisted heat output | ||||
Type of heat output/room temperature control (select one) | ||||
At nominal heat output | elmax | N/A | kW | Single stage heat output and no room temperature control |
At minimum heat output | elmin | N/A | kW | Two or more manual stages, no room temperature control |
In standby mode | elSB | 0.00094 | kW | With mechanic thermostat room temperature control |
With electronic room temperature control | ||||
Electronic room temperature control plus day timer | ||||
Electronic room temperature control plus week timer | ||||
Other control options (multiple selections possible) | ||||
Room temperature control, with presence detection | ||||
Room temperature control, with open window detection | ||||
With distance control option | ||||
With adaptive start control | ||||
With working time limitation | ||||
With black bulb sensor |
9. Disposal of Old Electrical Appliances
The European directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE), specifies that old household electrical appliances must not be disposed of with the normal unsorted municipal waste. Old appliances must be collected separately, in order to optimize the recovery and recycling of the materials they contain, and reduce the impact on human health and the environment.
The crossed out "wheeled bin" symbol (🚳) on the product reminds you of your obligation to dispose of the appliance correctly. If the product has a built-in battery or uses batteries, they should be removed from the appliance and disposed of appropriately.
Consumers must contact their local authorities or retailer for information concerning the correct disposal of old appliances and/or their batteries.
10. Technical Support Service and Warranty
This product is under warranty for 2 years from the date of purchase, as long as the proof of purchase is submitted, the product is in perfect physical condition, and it has been given proper use, as explained in this instruction manual.
The warranty will not cover the following situations:
- The product has been used for purposes other than those intended for it, misused, beaten, exposed to moisture, immersed in liquid or corrosive substances, as well as any other fault attributable to the customer.
- The product has been disassembled, modified, or repaired by persons, not authorised by the official Technical Support Service of Cecotec.
- Faults deriving from the normal wear and tear of its parts, due to use.
- The warranty service covers every manufacturing defects of your appliance for 2 years, based on current legislation, except consumable parts. In the event of misuse, the warranty will not apply.
If at any moment you detect any problem with your product or have any doubt, do not hesitate to contact Cecotec Technical Support Service at +34 96 321 07 28.