EDF3 Ventilation Control System
Installation and Wiring Manual
Item #: 463326
Rev Date: 2021-08-24
Product #: 415515
Selectable Operation Modes
An electronic wall control compatible with all Fantech HRV/ERV models. This control activates the system in three possible modes of operation:
- ECONO: Continuous operation in ventilation mode at low or medium speed.
- 20 MIN/H: 20 minutes ON, 40 minutes OFF (Intermittent mode).
- CONT: Continuous high speed in ventilation or recirculation mode.
- OFF: Standby mode, both fans off.
Introduction
This three-function wall control is compatible with all Fantech HRV/ERV models. It activates the system in three possible operating modes:
- ECONO: Continuous operation at low or medium speed.
- 20 MIN/H: 20 minutes ON, 40 minutes OFF (Intermittent mode).
- CONT: Continuous high speed in ventilation or recirculation mode.
- OFF: Standby mode, both fans off.
Wiring
Connect the wires to the EDF3 wall control. Insert the stripped end of the wires into the electrical connection terminals. Connect the wires to the "W" terminals on the EDF3 and to the "W" positions on the terminal connection block located on the fresh air appliance, near the power cord. Tighten screws using a slot head screwdriver.
Diagram Description: The wiring diagram shows connection points labeled 'W' on the EDF3 control and corresponding 'W' terminals on the fresh air appliance.
Jumper Settings
Before installing this control, the jumpers on the back can be changed to influence its operation.
Jumper JP1: Econo Mode Fan Speed
Selects if the Econo function triggers the fan to run at LOW or MEDIUM speed. JP1 is shipped from the factory set to LOW. To select MEDIUM speed, move the jumper to connect the JP1 center pin with the MED pin.
Jumper JP2: Continuous Mode
Selects if the Cont function triggers the Fresh Air Appliance to run continuously in ventilation mode (VENT) or recirculation mode (RECIRC). JP2 is shipped from the factory set to Ventilation mode. To select Recirculation mode, move the jumper to connect the JP2 center pin with the RECIRC pin.
Diagram Description: The jumper settings diagram illustrates the placement of jumpers JP1 and JP2 on the control board. JP1 has options for LOW and MED fan speeds for ECONO mode. JP2 has options for VENT (Ventilation) and RECIRC (Recirculation) for continuous mode.
Installation
Screw the control mounting plate to the electrical box, then screw the cover over the mounting plate.
Diagram Description: The installation diagram shows the mounting plate being secured to an electrical box with machine screws, followed by attaching the cover. The mounting plate and electrical box are noted as 'Not Included'.