2 User Registration 1.15m 0.5m 1.15m 0.5m 1.15m 0.5m For user heights between 1.5m to 1.8m, it is recommended to install the device at 1.15m height above ground (can be
Інструкції та ПЗ
File Info : application/pdf, 16 Pages, 2.45MB
DocumentDocumentQUICK START GUIDE ProBio(QR) Version: 1.0 Date: May 2021 Safety Precautions Before installation, please read the following precautions carefully to prevent risks and dangers to this product, users and surroundings. Do not expose to direct sunlight, water, dust and soot. Do not place any magnetic object near the product. Magnetic objects such as Magnet, CRT, TV, Monitor or Speaker may damage the device. Do not place the device next to any heating equipment. Prevent water, drinks or chemicals leaking into the device. This product is not intended for use by children unless they are supervised. Do not drop or damage the device. Do not disassemble, repair or modify the device. Do not use the device for any purpose other than those specified. Remove dusts or dirts regularly. While cleaning, wipe dust off with a smooth cloth or towel instead of water. Contact your supplier in case of any problem! 1 User Registration 1) Recommended Standing Position For user heights between 1.5m to 1.8m, it is recommended to install the device at 1.15m height above ground (can be modified according to the user's average height). 1.15m 0.5m 1.15m 1.15m 0.5m 0.5m Recommended Procedures (as shown in the left image): During registration and verification procedures, the position of device should not be changed to ensure high verification preciseness. If it is necessary to move the device, its vertical height should not be changed. 2) Registration a. During registration, it is required to adjust your upper body to fit your eyes into the green frame on the screen. b. During verification, it is required to show your face in the center of the screen and fit your face into the green frame in the screen. 2 Device Overview 2.8" Touch Screen 190.8mm (7.51") Doorbell Camera Card Reading Area & QR Code Scanner 85mm (3.35") Tamper Switch Terminal Block USB Port Reset Button 103mm (4.05") 3 Speaker Device Installation Installation on the wall Attach the mounting template sticker to the wall, and drill holes according to the mounting paper. Fix the back plate on the wall using the wall mounting screws. Attach the device to the back plate. Fasten the device to the back plate with a security screw. Fixing Hole Fixing Hole MPS201508 Mounting Positioning Sticker (only for your reference) Instruction on using Mounting Positioning Sticker: Before fastening the device, please stick this Mounting Positioning Sticker onto where you want to install the device, and then drill holes and lay cables according to the symbols on the sticker. Baseline Wiring Hole 10 11 12 Fixing Hole Fixing Hole 13 1.15m recommended height from the ground for facial terminal and 1.4m for finger vein terminal, it can be adjusted according to 14 the staff height. 15 61mm(2.4") 129 mm (5.08") 1.15m 4 Power Connection Without UPS { Auxiliary AUX In GND { BELLBell BELL+ { Sensor SEN { GND Button BUT { NO1 Lock COM1 NC1 { ALAlarm AL+ { Power +12V Out GND { Wiegand IWD0 In IWD1 Red LED RLED Green LED GLED Beep BEEP {Ethernet RJ45-1 RJ45-2 RJ45-3 RJ45-6 { WD0 Wiegand Out WD1 GND { RXD RS232 TXD GND { 485A RS485 485B { +12V Power In GND With UPS (Optional) GND 1 2 12V DC 12V DC { Auxiliary AUX In GND { BELLBell BELL+ { Sensor SEN { GND Button BUT { NO1 Lock COM1 NC1 { ALAlarm AL+ { Power +12V Out GND { Wiegand IWD0 In IWD1 Red LED RLED Green LED GLED Beep BEEP {Ethernet RJ45-1 RJ45-2 RJ45-3 RJ45-6 { WD0 Wiegand Out WD1 GND { RXD RS232 TXD GND { 485A RS485 485B { +12V Power In GND GND 1 2 12V DC 12V DC Recommended AC Adapter Recommended AC Adapter: 12V, 3A To share the power with other devices, use an AC Adapter with higher current ratings. 5 Ethernet Connection LAN Connection Connect the device and the software over an Ethernet cable. An example is shown below: { Auxiliary AUX In GND { BELLBell BELL+ { Sensor SEN { GND Button BUT { NO1 Lock COM1 NC1 { ALAlarm AL+ { Power +12V Out GND { Wiegand IWD0 In IWD1 Red LED RLED Green LED GLED Beep BEEP {Ethernet RJ45-1 RJ45-2 RJ45-3 RJ45-6 { WD0 Wiegand Out WD1 GND { RXD RS232 TXD GND { 485A RS485 485B { +12V Power In GND 1 4 Default IP Address: 192.168.1.201 Subnet Mask: 255.255.255.0 8 7 6 5 4 3 2 1 RJ 45 ZKBioSecurity IP Address: 192.168.1.61 Subnet Mask: 255.255.255.0 DESCRIPTION RJ45-1 RJ45-2 RJ45-3 RJ45-6 WIRE Yellow Green Red Black Note: In LAN, the IP Addresses of the Server (PC) and the device must be in the same network segment when connecting to the ZKBioSecurity software. Click [Comm.] > [Ethernet] > [IP Address], enter the IP address and click [OK]. 6 RS485 Connection Rs485 Slave Reader Connection { Auxiliary AUX In GND { BELLBell BELL+ { Sensor SEN { GND Button BUT { NO1 Lock COM1 NC1 { ALAlarm AL+ { Power +12V Out GND { Wiegand IWD0 In IWD1 Red LED RLED Green LED GLED Beep BEEP { RJ45-1 RJ45-2 Ethernet RJ45-3 RJ45-6 { WD0 Wiegand Out WD1 GND { RXD Rs232 TXD GND { 485A RS485 485B { +12V Power In GND 1 7 1 8 DESCRIPTION WIRE +12V Red GND Black IWD0 White IWD1 Green RLED Blue GLED Gray BEEP Purple DESCRIPTION WIRE WD0 Green WD1 White GND Black RXD Gray TXD Purple GND Black 485A Blue 485B Yellow Do not use Rs485 Slave Reader DIP Settings 1. There are six DIP switches on the back of RS485 slave reader, switches 1 to 4 are for RS485 address, switch 5 is reserved, and switch 6 is for reducing noise on a long RS485 cable. 2. If the RS485 slave reader is powered from the terminal, the length of wire should be less than 100 meters or 330 ft. 3. If the cable length is more than 200 meters or 600 ft., the number 6 switch should be turned ON as shown below. ON 123456 Distance: Less 200 meters Distance: More than 200 meters ON 123456 7 Lock Relay Connection The system supports both Normally Opened Lock and Normally Closed Lock. The NO Lock (Normally Opened when powered) is connected with 'NO' and 'COM' terminals, and the NC Lock (Normally Closed when powered) is connected with 'NC' and 'COM' terminals. The power can be shared with the lock or can be used separately for the lock, as shown in the example with NC Lock below: Device Not Sharing Power with the Lock 1 { Auxiliary AUX In GND { BELLBell BELL+ { Sensor SEN { GND Button BUT { NO1 Lock COM1 NC1 { ALAlarm AL+ { Power +12V Out GND { Wiegand IWD0 In IWD1 Red LED RLED Green LED GLED Beep BEEP { RJ45-1 RJ45-2 Ethernet RJ45-3 RJ45-6 { WD0 Wiegand Out WD1 GND { RXD RS232 TXD GND { 485A RS485 485B { +12V Power In GND COM1 12V DC 12 GND NC1 Sensor 12V DC DESCRIPTION WIRE AUX Brown GND BELL- Purple Green BELL+ Orange SEN Yellow GND Red BUT Blue NO1 White COM1 Black NC1 Gray AL- Black AL+ Red Do not use ! Do not reverse the polarities. GND GND + - FR107 Diode Normally Closed Lock 8 Lock Relay Connection Device Sharing Power with the Lock 1 { Auxiliary AUX In GND { BELLBell BELL+ { Sensor SEN { GND Button BUT { NO1 Lock COM1 NC1 { ALAlarm AL+ { Power +12V Out GND { Wiegand IWD0 In IWD1 Red LED RLED Green LED GLED Beep BEEP { RJ45-1 RJ45-2 Ethernet RJ45-3 RJ45-6 { WD0 Wiegand Out WD1 GND { RXD RS232 TXD GND { 485A RS485 485B { +12V Power In GND 12 GND COM1 12V DC 1 7 DESCRIPTION WIRE AUX Brown GND BELL- Purple Green BELL+ Orange SEN Yellow GND Red BUT Blue NO1 White COM1 Black NC1 Gray AL- Black AL+ Red DESCRIPTION +12V GND IWD0 IWD1 RLED GLED BEEP WIRE Red Black White Green Blue Gray Purple Do not use ! Do not reverse the polarities. Sensor GND GND NC1 FR107 Diode Normally Closed Lock 9 Standalone Installation ZKBioSecurity ZKBioSecurity Electric Lock Input Emergency Button Door Sensor USB Disk App Store Download Ethernet ProBio Output ALARM Alarm No Touch EXIT Exit Button % Output Doorbell RS485/ Wiegand Dynamic QR code Card Reader Google play 11 Wiegand Output Connection { Auxiliary AUX In GND { BELLBell BELL+ { Sensor SEN { GND Button BUT { NO1 Lock COM1 NC1 { ALAlarm AL+ { Power +12V Out GND { Wiegand IWD0 In IWD1 Red LED RLED Green LED GLED Beep BEEP { RJ45-1 RJ45-2 Ethernet RJ45-3 RJ45-6 { WD0 Wiegand Out WD1 GND { RXD Rs232 TXD GND { 485A RS485 485B { +12V Power In GND 1 8 DESCRIPTION WD0 WD1 GND RXD TXD GND 485A 485B WIRE Green White Black Gray Purple Black Blue Yellow Do not use WD1 WD0 GND ? ? ? ?B??E? E P ?G??L? ED ?W??D1 ?W??D0 ?G??N D ?+??1? 2 V ??? 10 Device Operation User Registration When there is no Super Administrator set in the device, click on to enter the menu. Add a new user and set the User Role to Super Admin. The system will request the Administrator's verification before entering the menu. It is recommended to register a Super Administrator initially for security purposes. Method 1: Register on the device Tap on > [User Mgt.] > [New User] to register a new user.The options include entering the User ID and Name, setting User Role, registering Face, Card Number, Password, adding User Photo, and setting Access Control role. Method 2: Register on ZKBioSecurity software Please set the IP Address and Cloud Service Server Address in the Comm. menu option on the device. 1. Click[Access]>[Device]>[Device]>[Search]tosearchthedeviceonthesoftware.When an appropriate Server Address and port is set on the device, the searched devices will be displayed automatically. Refresh New Delete Export Search Control Set up Step 1 Search View/Get Communication Search Total Progress IP Address No device found? Download Search Tools to Local Disk Step 2 Searched devices count:1 Device Type Serial Number IP Address MAC Address 192.168.163.201 Subnet Mask Gateway Address 255.255.255.0 192.168.163.201 Serial Number CJHC203336 Device Type Set Server ProBio OperationsStep 3 Add Add Device Name 192.168.163.201 Icon Type Area Door Area Name Add to Level Clear Data in the Device when Adding The current systen communication port[iCs l6e6a0r9D, patleaaisnetmheakDeesvuirceetwhehdenevAicdediisnsge]t wcoilrlredcetlleyt.e data in the device(except event record), please use with caution! Step 4 OK Cancel 12 Device Operation 2. Click [Add] in the operation column, a new window will pop-up. Select the Icon type, Area, and Add to Level from each drop-down and click [OK] to add the device. 3. Click [Personnel] > [Person] > [New] and fill in all the required fields to register a new user in the software. 4. Click [Access] > [Device] > [Control] > [Synchronize All Data to Devices] to synchronize all the data to the device including the new users. For more details, please refer the ZKBioSecurity User Manual. Ethernet and Cloud Server Settings Eg: 192.168.163.163 Eg: 192.168.163.1 Eg: 110.80.38.74 Eg: 6609 Click on > [COMM.] > [Ethernet] to set the network parameters. If theTCP/IP communication of the deviceissuccessful,theicon willbedisplayedintheupperrightcornerofthestandbyinterface. Click on > [COMM.] > [Cloud Server Setting] to set the Server Address and Server Port, the IP Address and Port Number of the server after the software is installed. If the device communicates with theServersuccessfully,theicon willbedisplayedintheupperrightcornerofthestandbyinterface. Access Control Settings Click on > [Access Control] to enter the access control management interface and set the relevant parameters of the access control. 13 Device Operation QR Code as the Mobile Credential The device can recognize the QR code image on the ZKBioSecurity Mobile APP captured by the QR code scanner, making it easy to access without contact. Please set the IP Address and Cloud Service Server Address in the COMM. menu option on the device. 1. Mobile APP Configuration After downloading and installing the , the user needs to set the Server before login. a. On the Server, choose [System] > [Authority Management] > [Client Register] to add a registered App client. b. Open the App on the Smartphone. On the login screen, tap [Server Setting] and type the IP Address or the Domain Name of the Server, and its Port Number. c. Tap the QR Code icon to scan the QR code of the new App client. After the client is identified successfully, set the Client Name and tap [Testing Connection]. d. After the network is connected successfully, tap [Save]. 2. Employee Mobile Login The Mobile Credential function is only valid when logging in as an employee. Tap on Employee to switch to Employee Login screen. Employees can login with the Personnel ID in [Personnel] > [Personnel] > [Person] and self-service password. The default selfservice password is 123456. 3. Scan the QR Code Find the access control QR code on the ZKBioSecurity Mobile App. Show the QR code to the QR code scanner of the device. The device prompts that the verification is successful. Note: 1. The user must have a card number registered in advance on the device or on the software. 2. When scanning, the QR code and the scanner must stay parallel at a distance of 15 to 30cm. For more details, please refer the ZKBioSecurity Mobile APP User Manual. Mobile Credential Eg: http://110.80.38.74 http://110.80.38.74 6609 Eg: 6609 4667D7 Mike 14 ZKTeco Industrial Park, No.32, Industrial Road, Tangxia Town, Dongguan, China. Tel: +86 769-82109991 Fax: +86 755-89602394 www.zkteco.com Copyright©2021 ZKTECO CO., LTD. All rights reserved.Acrobat Distiller 21.0 (Windows)