Shirokuma Wall Mounted RAK-PXB
Hitachi's Shirokuma systems are a premium range of stylish and highly-efficient wall mounted split systems. In ice white with a frosted sheer front panel combined with a matte and glass finish cabinet to reflect light, Shirokuma looks good from any angle.
Features and Benefits
- Capacities from 2.5kW to 5.8kW
- SCOP of 4.72 (A++) and SEER of 8.5 (A+++) for exceptional seasonal efficiency
- Elegant design complements any interior
- Low noise levels courtesy of Super Low fan speed
- Antibacterial Sanitizing
- Nano Titanium Wasabi filter for high air quality
- Energy saving sensor adjusts heating and cooling levels as room occupancy changes
- Weekly timer
- Compatible with H-LINK control and CS Net Web.
Remote Controllers
RAR-5E1 (NEW)
24-hour, 7-day infra red Remote Controller with features including:
- ECO operation energy saving function
- Leave Home Function: set temperature at 10°C automatically when no one is at home for up to 99 days
- Weekly Timer: 6 patterns
- Heating/Cooling Only operation: 2 ways of setting
- Room temperature display.
SPX-RCDB
Wired Remote Controller.
ErP-compliant products
ErP compliant, A++ to A+++ across the range.
Energy saving sensors
The sensor adjusts heating and cooling levels as room occupancy changes, allowing high energy savings.
Nano Titanium Wasabi Air Purification
A cutting-edge technology that uses a wasabi-modified Nano Titanium catalyst to provide a powerful antibacterial, anti-mould, anti-allergen, and deodorizing effect.
Comparison of Effects
Conventional anti-bacterial agents vs. Nano Titanium agents: Visual comparison indicating that Nano Titanium agents provide a higher removal ratio for bacteria and odors compared to conventional agents.
Ammonia Deodorizing Effect
A graph titled "Ammonia Deodorizing Effect" shows the percentage of odor removal over time. The Nano Titanium Wasabi Filter achieves 82% Odour Removal after 60 minutes, significantly outperforming the Plain Filter.
? *2 Test material: Nano Titanium Wasabi Air Purifying Filter (30.8 x 27.6cm 5T), Reactor volume: 1m³. Analysis: Gas Detector Tube Method. Flow rate through kit: 1m/s. Tested by the Nanopac Testing Laboratory.
Technical Specifications
Indoor Unit
RAK-25PXB | RAK-35PXB | RAK-50PXB | |
---|---|---|---|
Nominal Cooling Capacity (min-max) | 2.5 (0.9 - 3.1) kW | 3.5 (0.9 - 4.0) kW | 5.0 (1.9 - 5.2) kW |
Cooling Sensible Capacity | 2.3 kW | 3.0 kW | 3.7 kW |
UK Cooling Capacity (sensible) | 2.2 (2.0) kW | 2.7 (2.4) kW | 4.3 (2.8) kW |
Nominal Heating Capacity (min - max) | 3.20 (0.90- 4.20) kW | 4.00 (0.90- 4.80) kW | 5.80 (2.2- 7.00) kW |
Heating Capacity at -7°C(1) | 2.05 kW | 2.57 kW | 3.72 kW |
Nominal Cooling Power Input (min - max) | 0.545 (0.25 - 1.22) kW | 0.910 (0.25 - 1.4) kW | 1.560 (0.50 - 2.10) kW |
Nominal Heating Power Input (min - max) | 0.7 (0.25 - 1.2) kW | 0.955 (0.255 - 1.6) kW | 1.560 (0.50 - 2.70) kW |
Seasonal Efficiency SEER(3) | 8.5 | 8.5 | 7.2 |
Energy Efficiency Class | A+++ | A+++ | A++ |
Annual Energy Consumption | 150 kWh/yr | 209 kWh/yr | 300 kWh/yr |
Seasonal Efficiency SCOP(3) (Average Climate) | 4.7 | 4.72 | 4.5 |
Energy Efficiency Class | A++ | A++ | A+ |
Nominal Load Efficiency EER / COP(4) | 4.59 / 4.57 | 3.85 / 4.19 | 3.21 / 3.72 |
Annual Energy Consumption | 811 kWh/yr | 999 kWh/yr | 1,529 kWh/yr |
Energy Class (Cool/Heat) | A / A | A / A | A / A |
Noise Level Cooling (sound pressure) (SL / L / M / H) | 20/26/32/40 dB(A) | 22/29/35/42 dB(A) | 25/31/39/47 dB(A) |
Noise Level Heating (sound pressure) (SL / L / M / H) | 20/27/33/40 dB(A) | 22/30/35/42 dB(A) | 25/31/39/48 dB(A) |
Noise level (sound power)(2) | 55 dB(A) | 60 dB(A) | 60 dB(A) |
Air flow cooling mode (SL / L / M / H) | 300/330/510/560 m³/h | 320/340/430/580 m³/h | 350/400/580/720 m³/h |
Air flow heating mode (SL / L / M / H) | 290/370/560/610 m³/h | 310/360/480/630 m³/h | 350/420/620/800 m³/h |
Dehumidification | 1.4 l/h | 1.6 l/h | 2.0 l/h |
Dimensions (H x W x D) | 295 x 900 x 210 mm | 295 x 900 x 210 mm | 295 x 900 x 210 mm |
Weight | 11.0 Kg | 11.0 Kg | 11.0 Kg |
Power Supply | 35V DC from outdoor unit | 35V DC from outdoor unit | 35V DC from outdoor unit |
Drain Diameter (ext.) | φ16mm | φ16mm | φ16mm |
Remote Controller (standard) | Infra red RAR-5E1 | Infra red RAR-5E1 | Infra red RAR-5E1 |
Outdoor Unit
RAC-25WXB | RAC-35WXB | RAC-50WXB | |
---|---|---|---|
Noise level cooling (sound pressure) (night mode) | 46 dB(A) | 47 dB(A) | 51 dB(A) |
Noise level heating (sound pressure) (night mode) | 47 dB(A) | 49 dB(A) | 51 dB(A) |
Noise level (sound power)(2) | 60 dB(A) | 61 dB(A) | 65 dB(A) |
Air flow (Cooling / Heating) | 1860 / 1620 m³/h | 1920 / 1620 m³/h | 2160 / 2160 m³/h |
Dimensions (H x W x D) | 548 x 750 x 288 mm | 548 x 750 x 288 mm | 736 x 800 x 350 mm |
Weight | 34.0 Kg | 34.0 Kg | 49.5 Kg |
Piping diameter (Liquid / Gas) | 1/4 - 3/8 Inch (6.35 - 9.52 mm) | 1/4 - 3/8 Inch (6.35 - 9.52 mm) | 1/4 / 1/2 Inch (6.35 - 12.70 mm) |
Minimum Piping Length | 3 m | 3 m | 3 m |
Maximum Piping Length / Height Difference | 20 / 10 m | 20 / 10 m | 20 / 10 m |
Current Quantity of Refrigerant | 1.08 Kg | 1.17 Kg | 1.35 Kg |
Chargeless / Additional Refrigerant Charge | 20/- | 20/- | 20/- |
Power supply | 230V / 1Ph / 50Hz | 230V / 1Ph / 50Hz | 230V / 1Ph / 50Hz |
Recommended fuse size | 15 A | 15 A | 25 A |
Starting current | 5.0 A | 5.0 A | 8.0 A |
Running current (cooling / heating) | tbc | tbc | tbc |
Interconnecting Cables | 3 + E No. | 3 + E No. | 3 + E No. |
Working Range (cooling / heating) | -10°C~43°C / -15°C~21°C | -10°C~43°C / -15°C~21°C | -10°C~43°C / -15°C~21°C |
Refrigerant / GWP | R410A / 1975 | R410A / 1975 | R410A / 1975 |
Compressor type | Rotary | Rotary | Rotary |
? (1) Value includes the defrost ratio.
? (2) Sound power level is the A-weighted sound power level [dB(A)] measured at standard rated conditions for the "cooling" mode operation in accordance to EN12102.
? (3) Data calculated in accordance to prEN14825 and the Commission Communication 2012/C 172/01.
? (4) Nominal load efficiency (Cooling 35°C/27°C, Heating 7°C/20°C).
Contact Information
United Kingdom
Email: aircon.enquiries@hitachi-eu.com
Call: 01628 585 394
Ireland
Email: aircon.ireland@hitachi-eu.com
Call: 00 353 1 216 4406