Elinchrom ELC Pro HD Monolight

Quick Start Guide

Elinchrom Studio App / Software

Speed up your workflow with the Elinchrom App / Software and take control of your light wherever you are.

  • Control up to 20 units
  • Save and reload presets
  • Edit a friendly name
  • Change group by drag & drop

Available on macOS, Windows, Android and iOS.

Learn more: www.elinchrom.com/range/app-software/

Error Management

Error Code Description Solution
1 Capacitor over voltage Switch the unit off, wait 2 minutes and switch the unit on again. If the error shows up again the unit requires a check up at an authorized Elinchrom service centre.
2 Over heat Wait until the unit has cooled down. The unit will switch back to the normal operation as soon as the temperature decreases to a normal working level.
3 Discharge error Switch the unit off, wait 2 minutes and switch the unit on again. If the error shows up again the unit requires a check up at an authorized Elinchrom service centre.
4 Charge timeout error Switch the unit off, wait 2 minutes and switch the unit on again. If the error shows up again the unit requires a check up at an authorized Elinchrom service centre.
5 Zero detect fault Switch the unit off, wait 2 minutes and switch the unit on again. If the error shows up again the unit requires a check up at an authorized Elinchrom service centre.
6 Charge hold error Switch the unit off, wait 2 minutes and switch the unit on again. If the error shows up again the unit requires a check up at an authorized Elinchrom service centre.
8 Fan error Switch the unit off, wait 2 minutes and switch the unit on again. If the error shows up again the unit requires a check up at an authorized Elinchrom service centre.
10 Supply input voltage too high The unit has detected a mains supply fault. Please check the mains/battery supply. It could be not working correctly.
11 Supply input voltage too low The unit has detected a mains supply fault. Please check the mains/battery supply. It could be not working correctly.
12 Supply under voltage detected until charge The unit has detected a mains supply fault. Please check the mains/battery supply. It could be not working correctly.
15 Temperatur sensor "Heat Sink" not connected Switch the unit off, wait 2 minutes and switch the unit on again. If the error shows up again the unit requires a check up at an authorized Elinchrom service centre.
16 Temperatur sensor "Front" not connected Switch the unit off, wait 2 minutes and switch the unit on again. If the error shows up again the unit requires a check up at an authorized Elinchrom service centre.
17 Temperatur sensor "Charge" not connected Switch the unit off, wait 2 minutes and switch the unit on again. If the error shows up again the unit requires a check up at an authorized Elinchrom service centre.
20 Power Board not connected/found Switch the unit off, wait 2 minutes and switch the unit on again. If the error shows up again the unit requires a check up at an authorized Elinchrom service centre.
24 Capacitor voltage symmetry error Switch the unit off, wait 10 minutes and switch the unit on again. If the error shows up again the unit requires a check up at an authorized Elinchrom service centre.
28 Flash tube after glow Switch the unit off, wait 2 minutes and switch the unit on again. If the error shows up again the unit requires a check up at an authorized Elinchrom service centre.

Display Panel Information

Display Panel – Dashboard

The Dashboard displays the following information:

  • 1. EL-Skyport synchronisation: Indicates normal or speed mode.
  • 2. EL-Skyport Frequency channel: Shows the current frequency channel.
  • 3. EL-Skyport Group number: Displays the current group number.
  • 4. Photocell status: Indicates the status of the photocell.
  • 5. Ready beep: Indicates if the ready beep is on or off.
  • 6. Power in J: Displays the power output in Joules.
  • 7. Flash duration in s: Shows the flash duration in seconds.
  • 8. Flash function: Indicates the current flash function.
  • 9. Flash function value: Displays the value of the flash function.
  • 10. Increase 1 f-stop (R): Button to increase power by 1 f-stop.
  • 11. Open flash test (S): Button to perform an open flash test.
  • 12. Decrease 1 f-stop (L): Button to decrease power by 1 f-stop.
  • 13. Recycling mode: Shows the current recycling mode.
  • 14. Power in f-stop equivalent: Displays power in f-stop equivalent.

Display Panel – Modeling Lamp

Controls and displays for the modeling lamp:

  • 1. Setting title: Name of the current setting.
  • 2. Modelling lamp status: On/Off status of the modeling lamp.
  • 3. Back to dashboard (R): Button to return to the dashboard.
  • 4. Visual Flash Confirmation function (S): Activates visual flash confirmation.
  • 5. Proportional modelling lamp setup (L): Adjusts proportional modeling lamp settings.
  • 6. Proportional modelling lamp value: Sets the proportional value (e.g., -0.5 to -2.0 f-Stop).
  • 7. Visual Flash Confirmation status: Indicates status of visual flash confirmation.
  • 8. Modelling lamp power in f-stop: Displays modeling lamp power in f-stop.

Knob Color Info

Display Color Description
Green Ready
Green blinking Discharging
Orange Charging
Red blinking Flashing before 100% ready
Red breathing Stand by

Elinchrom Support and Information

For further assistance, please visit:

Website: www.elinchrom.com

Support Email: support@elinchrom.ch

Phone: +41 21 637 26 77

Address: Av. de Longemalle 11, CH-1020 Renens, Switzerland

Follow Elinchrom on social media: [Facebook] [YouTube]

Download the ELC Pro HD User Guide: www.elinchrom.ch/support

Elinchrom is a registered trademark of ELINCHROM LTD, RENENS, SWITZERLAND.

Document reference: QSG ELC PRO HD - 73019 - 06.2022

Models: EL20616.1, ELC Pro HD 1000 Flash Head, EL20616.1 ELC Pro HD 1000 Flash Head

File Info : application/pdf, 2 Pages, 599.83KB

PDF preview unavailable. Download the PDF instead.

220630 ELC-Pro-HD QSG

References

Adobe PDF Library 16.0.7 Adobe InDesign 17.3 (Macintosh)

Related Documents

Preview Elinchrom ONE Quick Start Guide: Features, Setup, and Operation
A concise guide to setting up and using the Elinchrom ONE portable flash unit, covering screen views, connection, settings, and control panel operation.
Preview Elinchrom FIVE Battery User Manual - Features, Specs, and Safety
Comprehensive user manual for the Elinchrom FIVE Battery, covering features, technical specifications, charging instructions, safety precautions, and legal information. Learn how to use and maintain your Elinchrom FIVE Battery.
Preview Elinchrom Transmitter Pro X Quick Start Guide
A concise guide to setting up and using the Elinchrom Transmitter Pro X, covering connection, interface controls, setup menu options, and regulatory information.