EG4® 280Ah Indoor Buildable Conduit Box Install Guide

Model #: CS-280-BD-IN-XY

©2024 EG4 ELECTRONICS, LLC. All Rights Reserved. Version 1.1.1 | Information subject to change without notice.

Table of Contents

1. Abbreviations

AbbreviationFull Name
AWGAmerican Wire Gauge
AAmps
AhAmp hour(s)
ACAlternating Current
AFCIArc-Fault Circuit Interrupter
AHJAuthority Having Jurisdiction
kAICkilo-Amp Interrupting Capability
ANSIAmerican National Standards Institute
BATBattery
BMSBattery Management System
COMCommunication
CTCurrent Transformer
DCDirect Current
DIPDual In-line Package
DODDepth of Discharge
EGEquipment Ground
EGSEquipment Grounding System
EMCElectromagnetic Compatibility
EPSEmergency Power System
ESSEnergy Storage System
E-StopEmergency Stop
FCCFederal Communication Commission
GEGrounding Electrode
GECGrounding Electrode Conductor
GFCIGround Fault Circuit Interrupter
GFDIGround Fault Detector/Interrupter
ImpMaximum Power Point Current
IEEEInstitute of Electrical and Electronic Engineers
IPIngress Protection
IscShort-Circuit Current
In-lbs.Inch Pounds
kWKilowatt
kWhKilowatt-hour
LCDLiquid Crystal Display
LFPLithium Iron Phosphate
L1Line 1
L2Line 2
mmMillimeters
MPPTMaximum Power Point Tracking
mVMillivolt
NNeutral
NECNational Electric Code
NEMANational Electrical Manufacturers Association
NFPANational Fire Prevention Association
NmNewton Meters
NOCTNormal Operating Cell Temperature
PCPersonal Computer
PCBPrinted Circuit Board
PEProtective Earth
PPEPersonal Protective Equipment
PVPhotovoltaic
RSDRapid Shut Down
SCCStandards Council of Canada
SOCState of Charge
STCStandard Testing Conditions
ULUnderwriters Laboratories
UPSUninterrupted Power Supply
VVolts
VOCOpen-Circuit Voltage
VMPVoltage Maximum Power

2. Brief Description

The EG4® Indoor Buildable Conduit Box allows users a simple and effective way to protect cables and connections between battery and inverter. The conduit box is designed to pair the EG4 WallMount Indoor 280Ah Lithium Battery with either the EG4 FlexBOSS21, 18kPV Hybrid, 12kPV Hybrid, 6000XP Off-Grid, or the 12000XP Off-Grid Inverter*.

? NOTE: When using the 12000XP Off-Grid Inverter, the optional 12000XP conduit box top plate (sold separately) will be used instead of the normal top plate.

3. Packing List

The items listed below will arrive with the product shipment:

ItemDetails
Disassembled Indoor Buildable Conduit Box6 pieces. Total Weight: 14.70 lbs. (6.66 kg)
M6 x 1.0 Phillips Flat Head Screwx10
M6 x 1.0 Phillips Hex Head Screw w/ Washer setx4
M6 x 1.0 Phillips Hex Head Screw w/ Washer set (for battery mounting)x4
12000XP Conduit Box Top Plate*Sold separately
Rotating Cover
ModelQty
GLW-M634
GLW-M501
GLW-G 12
GLW-PG212
Grommets
ModelQty
RSB-282
RSB-352
RSB-501
RSB-634

4. Tools Needed

5. Conduit Box Knockout/Hole Patterns & Schematics

5.1 Exterior Dimensions

Diagram showing Top View of the conduit box with mounting holes and various circular knockouts. Dimensions are provided for overall size and knockout placement.

Overall Dimensions (Top View):

  • Width: 20.47in [520.00mm]
  • Depth: 9.82in [249.50mm]
  • Mounting Hole Offset from Edge: 0.46in [11.58mm]

Diagram showing Front View of the conduit box with mounting holes and knockout details. Dimensions are provided for overall size and knockout placement.

Overall Dimensions (Front View):

  • Width: 20.47in [520.00mm]
  • Height: 9.06in [230.00mm]
  • Mounting Hole Offset from Edge: 0.46in [11.58mm]
  • Vertical dimensions for mounting holes and knockouts are also detailed.

5.2 Right & Left Side Plate Knockout Dimensions

Diagram showing the Right Plate with multiple circular knockouts of varying sizes and positions. Dimensions for knockout diameters and distances from edges are provided.

Right Plate Dimensions:

  • Overall Width: 8.43in [214.00mm]
  • Overall Height: 7.71in [195.92mm]
  • Specific knockout dimensions and positions are detailed in the diagram.

Diagram showing the Left Plate with multiple circular knockouts of varying sizes and positions. Dimensions for knockout diameters and distances from edges are provided.

Left Plate Dimensions:

  • Specific knockout dimensions and positions are detailed in the diagram.

5.3 Top Plate Knockout Dimensions

Diagram showing the Top Plate with multiple circular knockouts of varying sizes and positions. Dimensions for knockout diameters and distances from edges are provided.

Top Plate Dimensions:

  • Overall Width: 20.47in [520.00mm]
  • Specific knockout dimensions and positions are detailed in the diagram.

5.4 12000XP Top Plate* Knockout Dimensions

Diagram showing the specific 12000XP Top Plate for the 12000XP Off-Grid Inverter, featuring circular knockouts. Dimensions for knockout diameters and distances from edges are provided.

? NOTE: When using the 12000XP Off-Grid Inverter, this optional 12000XP conduit box top plate will be used instead of the normal top plate.

6. Conduit Box Assembly

The Indoor Buildable Conduit Box is a highly recommended accessory to enclose all battery cables for added protection and safety. The conduit box holds the wiring that runs between the inverter and the battery.

Exploded view diagram illustrating the assembly of the conduit box components.

Assembly Parts List:

No.Item
1Bottom Plate
2Left Side Plate
3Right Side Plate
4Back Plate
5Front Plate
6Top Plate
7Ground Screw and Wire
812000XP Top Plate*

? NOTE: When using the 12000XP Off-Grid Inverter, the optional 12000XP conduit box top plate will be used instead of the normal top plate.

Assembly Instructions:

? NOTE: Bottom plate should have the GROUND screw and wire (labeled 7) to the back left when viewing the front for assembly.

  1. Starting with the bottom plate (labeled 1), ensure the ground screw and wire are securely fastened. Align the left-side plate (labeled 2) with the holes on the bottom plate. Attach the left-side plate using three of the included M6 x 1.0 Phillips flat head screws.
  2. Locate the right-side plate (labeled 3), align with the holes in the bottom plate. Attach to the bottom plate using three of the included M6 x 1.0 Phillips flat head screws.
  3. Locate the back plate (labeled 4), align and attach using four of the M6 x 1.0 Hex head screw with washer set. Install the M6 x 1.0 Hex head screw with washer set going from the inside of the box to the outside.
  4. Locate the front plate (labeled 5), align and attach using the pre-installed thumbscrews.
  5. If pairing with the 12000XP Off-Grid inverter*, proceed to the next step. Locate the top plate (labeled 6), align with holes on top of the left and right-side plates. Attach the top plate using four of the included M6 x 1.0 Phillips flat head screws.
  6. Locate and use the 12000XP conduit box top plate* to ensure correct alignment of knockouts. Align with the holes on top of the left and right-side plates. Attach the 12000XP conduit box top plate using four of the included M6 x 1.0 Phillips flat head screws.
  7. Use the remaining four M6 x 1.0 Hex head screw with washer set to mount the conduit box to the battery.

Notes

This section is for user notes.

Models: 280Ah Indoor Buildable Conduit Box, 280Ah, Indoor Buildable Conduit Box, Buildable Conduit Box, Conduit Box, Box

File Info : application/pdf, 12 Pages, 1.07MB

PDF preview unavailable. Download the PDF instead.

EG4SPIDWMBCNDTS GUIDE-INSTALL-EN

References

Adobe PDF Library 24.5.96

Related Documents

Preview EG4 12kPV Hybrid Inverter: Powerful and Scalable Solar Energy Solution
Discover the EG4 12kPV, a compact and cost-effective 48V split-phase hybrid inverter for rural and suburban homeowners. Features swift setup, all-in-one control, reliable monitoring, and future-ready integration for seamless energy independence.
Preview EG4 18KPV User Manual: Installation, Operation, and Troubleshooting Guide
Comprehensive user manual for the EG4 18KPV hybrid solar inverter, covering installation, system connections, operation modes, monitoring setup, and troubleshooting. Learn how to safely and effectively use your EG4 18KPV system.
Preview EG4 Mobile App Firmware Update Guide
A step-by-step guide on how to update the firmware of EG4 inverters using the EG4 Mobile App. Covers downloading firmware, connecting to the dongle, and completing the update process.
Preview EG4 Hybrid Inverters: Backfed Breaker Installation Configuration
Detailed explanation of the backfed breaker installation method for EG4 Hybrid Inverters, including the 18kPV model, and its operational characteristics during grid outages.
Preview EG4 WallMount All Weather Battery Quick-Start Guide
This quick-start guide provides essential information for the safe and effective installation of the EG4 WallMount All Weather battery. It covers safety instructions, packing contents, location selection, mounting procedures, wiring, parallel installation, BMS communication setup, and firmware updates. Designed for installers and users of EG4 battery systems.
Preview EG4 Monitor Center Firmware Updates Guide
A step-by-step guide for distributors and installers to update inverter firmware using the EG4 Electronics Monitor Center. Learn how to log in, select maintenance, perform remote updates, and troubleshoot common issues.
Preview EG4 Hybrid Inverters Anti-Islanding Method Statement
Manufacturer's statement detailing the anti-islanding methodology used by EG4 Hybrid Inverters, compliant with IEEE STD. 1547 and UL STD. 1741.
Preview EG4 12kPV Hybrid Inverter: Device Monitoring & Settings Guide
Comprehensive guide to the EG4 12kPV Hybrid Inverter, covering device monitoring, system settings, operation modes, and technical specifications for optimal performance and management.