40LM Fan Coil Unit Series
The 40LM Fan Coil Unit Series is equipped with innovative technologies and a versatile design to meet the needs of diverse applications such as residential spaces, hotels, offices, hospitals, and multi-room buildings.
The system is a chilled water, furred-in model with Plenum Fan Coil units. Its low-silhouette construction makes it an ideal choice across various building types. It is offered with an insulated & painted condensate drain pan and a factory-fitted frame complete with filter media.
Standard features include a 3-speed direct drive motor and up to 4 cooling coils to provide maximum cooling capacity and efficiency. A standard copper tube aluminum fin (Cu/Al) evaporator coil is included for maximum heat transfer performance. Energy-efficient performance is ensured with Carrier's Lanced Sine Wave Fin pattern.
Technical Specifications
GENERAL | Model | 040 | 050 | 060 | 070 | 100 | 120 | 150 | 200 | |
---|---|---|---|---|---|---|---|---|---|---|
kW | Btu/hr | l/s | ||||||||
Type | Chilled Water Fan Coil Unit | |||||||||
Nominal Capacity | kW | 8.8 | 11.7 | 14.8 | 19.1 | 27.0 | 29.8 | 43.7 | 62.2 | |
Btu/hr | 30,139 | 39,866 | 50,652 | 65,218 | 92,268 | 1,01,745 | 1,49,379 | 2,06,278 | ||
Air Quantity (Range) | l/s | 699 | 643 | 795 | 907 | 1,321 | 1,420 | 2,148 | 2,926 | |
Power Supply | V / Ph /Hz | 230 / 1 / 50 | ||||||||
Fan | Type | Centrifugal Forward-Curved Blades | ||||||||
Drive | Direct Drive | |||||||||
Quantity | Pcs | 2 | 3 | |||||||
Motor | Type | Permanent Split Capacitor, 3 Speeds | ||||||||
Quantity | Pcs | 1 | 2 | |||||||
Power Output | W | 300 | 450 | 450 | 750 | 800 | 800 | 960 / 640 | 800 / 462 | |
Full Load Amp | A | 2.50 | 3.00 | 3.00 | 6.07 | 7.84 | 11.59 | 12.93 | 150 | |
Coil | Type | Copper Tube, Aluminium Plate Fins | ||||||||
Row - Fins/in (Face Area m2) | 4 - 15 (0.33) | 4 - 18 (0.33) | 4 - 18 (0.40) | 4 - 15 (0.60) | 4 - 15 (0.60) | 4 - 15 (0.81) | 4 - 18 (1.08) | 4 - 15 (0.33) | ||
Filter | Type | Washable | ||||||||
Quantity | Pcs | 1 | 2 | 1 | 1 | 1 | 2 | 2 | 1 | |
Connections | Supply | Inch | 1" BSPT MPT | 1" BSPT MPT | 3/4" NPT MPT | |||||
Return | Inch | |||||||||
Drain Pipe | Inch | |||||||||
Dimensions | Height | mm | 347 | 458 | 469 | 680 | 965 | 965 | 963 | 965 |
Width | mm | 749 | 675 | 963 | 965 | 965 | 965 | 965 | 965 | |
Length | mm | 1,067 | 1,627 | 1,990 | 1,946 | 1,946 | 1,946 | 1,946 | 1,946 | |
Weight | Net Weight | kg | 42.5 | 42.5 | 47.5 | 78.0 | 78.0 | 111.0 | 160.0 | 46.5 |
Gross Weight | kg | 46.5 | 46.5 | 51.5 | 90.0 | 90.0 | 123.0 | 172.0 | 51.5 |
Physical Dimensions
Detailed physical dimensions are provided for various models:
- Physical dimensions for 40LM040, 40LM050, and 40LM060 models, showing variations in height, width, and length.
- Physical dimensions for the 40LM070 model, detailing its height, width, and length.
- Physical dimensions for 40LM100 and 40LM120 models, illustrating their respective heights, widths, and lengths.
- Physical dimensions for the 40LM150 model, showing its height, width, and length.
- Physical dimensions for the 40LM200 model, detailing its height, width, and length.
Installation diagram illustrating unit placement, showing a top panel, side panel, and flexible duct connection. It indicates recommended clearance spaces of 305mm (12 inches), 889mm (35 inches), and 610mm (24 inches) for servicing and airflow, and references wiring specifications.
Preliminary Checks and Installation Requirements
Before installing the unit, ensure installation personnel are familiar with the following requirements:
- Space Requirement and Clearance
- Ceiling or Mounting Strength
- Condensate Drain Connection
- Power Supply and Wiring
- Piping Connections
- Air Duct Connections
Location, Mounting, and Isolation
The unit should be installed for horizontal discharge only. Suspend the unit horizontally using factory-provided holes located on the top side flanges. Do not restrict service areas. Refer to diagrams for recommended minimum clearance space. Clearance space beneath the unit may be acceptable provided the ceiling offers sufficient access for servicing and maintenance.
Select and adjust vibration isolators and suspension rods to ensure the unit is uniformly suspended. Verify ceiling strength is sufficient to support the unit load based on approximate unit weight.
Ductwork should be installed according to the Carrier System Design Manual and all applicable codes. Use flexible connections to minimize duct-to-unit alignment problems and reduce vibration and noise transmission.
A Legacy of Innovation
In 1902, Willis Carrier created the world's first modern air conditioning system, fundamentally changing indoor life. Carrier continues to draw inspiration from this breakthrough, introducing new technologies to enhance comfort. A nationwide network of experts advances Willis Carrier's lifework, with local Carrier dealers equipped to create customized systems tailored to individual lifestyles.
Contact Information
Carrier International Sdn. Bhd. (3385-T)
Lot 4, Jalan P/6, 43650 Bandar Baru Bangi, Selangor Darul Ehsan, Malaysia.
Tel: 03-8913 7600