40LM Chilled Water Fan Coil Unit

A Benchmark in Versatile Cooling Performance

About Carrier International Sdn Bhd

Carrier International Sdn Bhd (CISB) is a state-of-the-art manufacturing facility employing the latest technologies and expertise to provide comprehensive HVAC solutions. CISB serves customers in over 20 countries across the Middle East and Asia Pacific. With decades of honed insights, Carrier has earned the trust of stakeholders worldwide, including industry-accredited institutions that have awarded multiple accolades.

Location: Selangor, Malaysia

Operations: 1962–present

CISB also serves as a Regional Multi-purpose Training Hub and Experience Centre.

40LM Fan Coil Unit Series

The 40LM Fan Coil Unit Series is equipped with innovative technologies and a versatile design to meet the needs of diverse applications such as residential spaces, hotels, offices, hospitals, and multi-room buildings.

The system is a chilled water, furred-in model with Plenum Fan Coil units. Its low-silhouette construction makes it an ideal choice across various building types. It is offered with an insulated & painted condensate drain pan and a factory-fitted frame complete with filter media.

Standard features include a 3-speed direct drive motor and up to 4 cooling coils to provide maximum cooling capacity and efficiency. A standard copper tube aluminum fin (Cu/Al) evaporator coil is included for maximum heat transfer performance. Energy-efficient performance is ensured with Carrier's Lanced Sine Wave Fin pattern.

Technical Specifications

GENERAL Model 040 050 060 070 100 120 150 200
kW Btu/hr l/s
Type Chilled Water Fan Coil Unit
Nominal Capacity kW 8.811.714.819.127.029.843.762.2
Btu/hr 30,13939,86650,65265,21892,2681,01,7451,49,3792,06,278
Air Quantity (Range) l/s 6996437959071,3211,4202,1482,926
Power Supply V / Ph /Hz 230 / 1 / 50
Fan Type Centrifugal Forward-Curved Blades
Drive Direct Drive
Quantity Pcs 23
Motor Type Permanent Split Capacitor, 3 Speeds
Quantity Pcs 12
Power Output W 300450450750800800960 / 640800 / 462
Full Load Amp A 2.503.003.006.077.8411.5912.93150
Coil Type Copper Tube, Aluminium Plate Fins
Row - Fins/in (Face Area m2) 4 - 15 (0.33)4 - 18 (0.33)4 - 18 (0.40)4 - 15 (0.60)4 - 15 (0.60)4 - 15 (0.81)4 - 18 (1.08)4 - 15 (0.33)
Filter Type Washable
Quantity Pcs 12111221
Connections Supply Inch 1" BSPT MPT1" BSPT MPT3/4" NPT MPT
Return Inch
Drain Pipe Inch
Dimensions Height mm 347458469680965965963965
Width mm 749675963965965965965965
Length mm 1,0671,6271,9901,9461,9461,9461,9461,946
Weight Net Weight kg 42.542.547.578.078.0111.0160.046.5
Gross Weight kg 46.546.551.590.090.0123.0172.051.5

Physical Dimensions

Detailed physical dimensions are provided for various models:

Installation diagram illustrating unit placement, showing a top panel, side panel, and flexible duct connection. It indicates recommended clearance spaces of 305mm (12 inches), 889mm (35 inches), and 610mm (24 inches) for servicing and airflow, and references wiring specifications.

Preliminary Checks and Installation Requirements

Before installing the unit, ensure installation personnel are familiar with the following requirements:

Location, Mounting, and Isolation

The unit should be installed for horizontal discharge only. Suspend the unit horizontally using factory-provided holes located on the top side flanges. Do not restrict service areas. Refer to diagrams for recommended minimum clearance space. Clearance space beneath the unit may be acceptable provided the ceiling offers sufficient access for servicing and maintenance.

Select and adjust vibration isolators and suspension rods to ensure the unit is uniformly suspended. Verify ceiling strength is sufficient to support the unit load based on approximate unit weight.

Ductwork should be installed according to the Carrier System Design Manual and all applicable codes. Use flexible connections to minimize duct-to-unit alignment problems and reduce vibration and noise transmission.

A Legacy of Innovation

In 1902, Willis Carrier created the world's first modern air conditioning system, fundamentally changing indoor life. Carrier continues to draw inspiration from this breakthrough, introducing new technologies to enhance comfort. A nationwide network of experts advances Willis Carrier's lifework, with local Carrier dealers equipped to create customized systems tailored to individual lifestyles.

Contact Information

Carrier International Sdn. Bhd. (3385-T)

Lot 4, Jalan P/6, 43650 Bandar Baru Bangi, Selangor Darul Ehsan, Malaysia.

Tel: 03-8913 7600

©2025 Carrier. All Rights Reserved. This catalogue provides certain general information and is intended for general guidance only. Carrier is not liable for any damage arising out of the use of this catalogue. Images shown are for reference only, actual products may vary. The manufacturer reserves the right to change product specifications without prior notice.

Models: 40LM-040, 40LM-050, 40LM-060, 40LM Chilled Water Fan Coil Unit, 40LM, Chilled Water Fan Coil Unit, Water Fan Coil Unit, Fan Coil Unit, Coil Unit, Unit

PDF preview unavailable. Download the PDF instead.

Carrier 40LM refresh Catalogue 2025 V2 tcm865-257371 Adobe PDF Library 17.0 Adobe InDesign 20.1 (Macintosh)

Related Documents

Preview Carrier 42CT AC & BLDC Motor Fan Coil Unit Specifications and Features
Detailed specifications, features, and technical data for the Carrier 42CT AC and BLDC Motor Fan Coil Unit, including performance parameters, dimensions, and electrical data.
Preview Carrier 42NX Ductable Fan Coil Unit - Product Specifications
Detailed specifications and performance data for the Carrier 42NX ductable fan coil unit, covering cooling and heating capacities, airflow, sound levels, electrical data, and various configuration options.
Preview Carrier 40VNS Series 4-Way Cassette Air Conditioner Installation Manual
This installation manual provides detailed instructions for the Carrier 40VNS series 4-way cassette chilled water fan coil units. It covers safety precautions, installation procedures, wiring diagrams, testing, maintenance, and troubleshooting.
Preview Carrier 4-Way Cassette Air Conditioner User Manual
User manual for Carrier 4-way cassette chilled water fan coil units, model series 40VNS, providing operating instructions, maintenance guidelines, and troubleshooting tips.
Preview Carrier 42NL et 42NH : Ventilo-convecteurs Gainables - Spécifications Techniques
Découvrez la gamme de ventilo-convecteurs gainables Carrier 42NL et 42NH. Ce guide technique détaille les performances, dimensions, configurations et spécifications pour une sélection optimale de votre unité CVC.
Preview Carrier 42DH/42DV Series Fan Coil Air Conditioners Product Data
Carrier's 42DH and 42DV Series Fan Coil Air Conditioners offer efficient and flexible climate control for various buildings. These direct drive units feature EC motors, robust construction, and multiple configurations for easy installation and optimized performance. This product data sheet details AHRI ratings, specifications, and options for models ranging from 600 to 3000 cfm.
Preview Carrier FT5 Fan Coil: Performance, Efficiency, and InteliSense™ Technology
Explore the Carrier FT5 Fan Coil, featuring InteliSense™ technology, Puron Advance® refrigerant, and a variable speed ECM motor for superior comfort, efficiency, and environmental responsibility. View detailed specifications, performance data, and model information for residential and light commercial HVAC applications.
Preview Carrier NAVA4 Accessory Coil Installation Instructions
This document provides detailed installation instructions for the Carrier NAVA4 Accessory Coil, designed for FEV fan units. It covers safety precautions, procedures for downflow and upflow applications, refrigerant tubing, condensate drain setup, unit start-up, and maintenance. Includes wiring diagrams and airflow performance data for R-410A systems.