User Manual for MEAN WELL models including: LCM-40TW, 40W Constant Power Mode With Tunable White LED Driver, LCM-40TW 40W Constant Power Mode, 40W Constant Power Mode, Constant Power Mode, Power Mode, LCM-40TW 40W Constant Power Mode With Tunable White LED Driver, Power Mode With Tunable White LED Driver, Tunable White LED Driver

LCM-40TW

欧诗全

LCM-40TW


File Info : application/pdf, 7 Pages, 1.19MB

PDF preview unavailable. Download the PDF instead.

LCM-40TW DS 001
40W Constant Power Mode With Tunable White LED Driver

LCM-40TW series
User's Manual



2









 
  II      

Note.10
 
      
 
 

 
                                                                                    

     

  

File Name:LCM-40TW-SPEC 2022-05-27

LCM-40TW 40W Constant Power Mode With Tunable White LED Driver

series

SPECIFICATION

MODEL

LCM-40TW

OUTPUT CHANNEL DC VOLTAGE RANGE NO LOAD VOLTAGE

CH1 20~50V 53V

CH2 20~50V 53V

DEFAULT CURRENT

700mA

700mA

OUTPUT

CURRENT ADJ. RANGE (BY DIP SWITCH)

500~1050mA

500~1050mA

RATED POWER

40W Max. total

CURRENT RIPPLE Note5 <2%

DIMMING RANGE

0~100%

START UP TIME Note9 500ms/230VAC

VOLTAGE RANGE

180~277VAC

260~390VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR

PF0.98/230VAC,PF0.95/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)

INPUT

TOTAL HARMONIC DISTORTION

THD< 10%(@load 50%/230VAC; @load 75%/277VAC) (Please refer to "TOTAL HARMONIC DISTORTION(THD)" section)

EFFICIENCY(Typ.) Note4 87%

AC CURRENT
INRUSH CURRENT
LEAKAGE CURRENT STANDBY POWER CONSUMPTION Note6

PROTECTION

OVERLOAD SHORT CIRCUIT

0.23A/230VAC COLD START 20A(twidth=310s measured at 50% Ipeak) at 230VAC; Per NEMA 410 <0.75mA / 277VAC
standby power consumption<0.5W (Dimming off)
105~135% rated output power Protection type: Hiccup mode, recovers automatically after fault condition is removed. Constant current limiting, recovers automatically after fault condition is removed

OVER TEMPERATURE WORKING TEMP. MAX. CASE TEMP.

Stage 1: Derating to 70% loading; stage2: Shut down.Recovers automatically after fault condition is removed Tcase=-30~85 (Please refer to " OUTPUT LOAD vs TEMPERATURE" section) Tcase=85

WORKING HUMIDITY

20 ~ 90% RH non-condensing

ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/ (0 ~ 50)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

OPERATING ALTITUDE 2000 meters

SAFETY STANDARDS

ENEC EN61347-1, EN61347-2-13(EL) appendix J suitable for emergency installations; EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;

DALI STANDARDS

Comply with IEC62386-101, 102, 207(DT6),209(DT8),251

SAFETY&EMC

WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF

I/P-O/P:3.75KVAC I/P-O/P:>100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55015, EN61000-3-2 Class C(@load 50%) ; EN61000-3-3; GB17625.1,GB17743, EAC TP TC 020 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level(surge immunity Line-Line 2KV), EAC TP TC 020 2111.7K hrs min. Telcordia SR-332 (Bellcore) 177.4Khrs min. MIL-HDBK-217F (25)

OTHERS

DIMENSION

123.5*81.5*23mm (L*W*H)

PACKING

0.24Kg ; 54pcs/15Kg/1.12CUFT

NOTE

     ~             ,    https://www.meanwell.com/serviceDisclaimer.aspx

File Name:LCM-40TW-SPEC 2022-05-27

LCM-40TW 40W Constant Power Mode With Tunable White LED Driver

series

BLOCK DIAGRAM

EMI FILTER

I/P

&

RECTIFIERS

POWER SWITCHING

O.L.P.

PWM&PFC CONTROL

RECTIFIERS &
FILTER
O.T.P.

DC to DC
DC to DC
CURRENT & VOLTAGE LIMIT
DETECTION CIRCUIT

+V -V1
+V -V2
DA+/PUSH DA-/N

DRIVING METHODS OF LED MODULE

 I-V Operating Area  LCM-40TW
For 40W application

55V 500mA,50V 700mA,50V 800mA,50V
50V

45V

40V 1050mA,38V
35V

30V

25V 500mA,27V
20V
15V

680mA,20V

1050mA,20V

400mA 500mA 600mA 700mA 800mA 900mA 1000mA 1100mA1200mA

DIP SWITCH TABLE
LCM-40TW is a multiple-stage constant power driver, selection of output current through DIP switch is exhibited below.

Vo Io
27~50V 500mA 25~50V 600mA

DIP S.W 1 2 3
---- ON ON ON ON ON ---- ---- ON ON ---- ON

20~50V 700mA(factory default) ON ON ----

20~50V 800mA

---- ON ----

Status DIP S.W 4

5

Activatied Channel

Single-address DT6 ---- ON CH1

Dual-address DT6 ON ON CH1,CH2

Single-address DT8 ---(factory default) ON

-------

CH1,CH2

20~44V 900mA

ON ---- ----

20~38V 1050mA

---- ---- ----

Note: 1.For more current setting,please contact MW's sales. 2.The operating voltage range which show on this table is recommend to use.

File Name:LCM-40TW-SPEC 2022-05-27

LCM-40TW 40W Constant Power Mode With Tunable White LED Driver

series

DIMMING OPERATION
Output wiring diagram
AC/L AC/N Push Button

AC/L AC/N
DA+/PUSH DA-/N

LCM-40TW

AC/L AC/N
DA+ DA-

AC/L AC/N
DA+/PUSH DA-/N

LCM-40TW

PUSH dimming (primary side)
·The factory default dimming level is at 100%. ·If the push action lasts less than 0.05 sec., it will not lead to a change for the status of the driver. ·Up to 10 drivers can perform the PUSH dimming at the same time when utilizing one common push button. ·The maximum length of the cable from the push button to the last driver is 20 meters.

Action Short Push Double Click Long Push

Action duration 0.1~1s Click twice in 1.5s 1.5~10s

PUSH dimming functions table

Status
DT6 (Single Address)

Output CH1

DT6 (Dual Address)

CH1,CH2

DT8

CH1(C.W.) ,

(Single Address) CH2(W.W.)

Push button function
Short Push : ON/OFF Double Click : go to maximum. Long Push: Dim up/down. - dim up stop at maximum; dim down stop at min dim (not dim off) - with next push, direction change (up/down) - dim up possible even if when unit is in standby mode (dim off mode)
Short Push: ON/OFF Double Click : go to maximum. Long Push : Dim up+CCT cooler/Dim down+CCT warmer - dim up stop at maximum; dim down stop at min dim (not dim off) - with next push, direction change (up/down) - dim up possible even if when unit is in standby mode (dim off mode)
Short Push : ON/OFF Double Click : Switch between Dim control or CCT control mode Long Push : Dim up/down or CCT control - dim up stop at maximum; dim down stop at min dim (not dim off) - with next push, direction change (up/down, warm/cold) - dim up possible even if when unit is in standby mode (dim off mode)

File Name:LCM-40TW-SPEC 2022-05-27

Output current (%) CCT setup range

LCM-40TW 40W Constant Power Mode With Tunable White LED Driver

series

DIMMING CURVE
Dimming characteristics
100% 90% 80% 70% 60% 50% 40% 30% 20% 10%
0% 0 15 30 45 60 75 90 105 120 135 150 165 180 195 210 225 240 255
Dimming Level
OUTPUT CONNECTIONS

Dynamic range in colour temperature control

Cool white

0.2%

Operating Window

Warm white 100%

100 % - 0.2 % Dimming range

0.2%
0.4%

Application
One channel output control(DT6)
Two channels output control(DT6)
Tunable white control(DT8)

Output channels Single address Dual address Single address

Output connections schematic diagram
CH1 CH2 +V +V -V1 -V2
CH1 CH2 +V +V -V1 -V2
CH1 CH2 +V +V -V1 -V2
c.w w.w

LOAD (%)

OUTPUT LOAD vs TEMPERATURE

100 80 60 40 20

-30 -15

0

15

30

40 45 50 60

70 (HORIZONTAL)

AMBIENT TEMPERATURE,Ta ()
STATIC CHARACTERISTIC

LOAD (%)

100 90 80 70 60 50 40
180 190 200 210 220 230 240 250 260 270 280 295
INPUT VOLTAGE (V) 60Hz De-rating is needed under low input voltage.

LOAD (%)

100 80 60 40 20

-30

0

20

45

55

65

75 85 90 (HORIZONTAL)

Tcase ()

File Name:LCM-40TW-SPEC 2022-05-27

THD

LCM-40TW 40W Constant Power Mode With Tunable White LED Driver

series

TOTAL HARMONIC DISTORTION (THD)

 Tcase at 85
10 9 8 7 6 5 4 3 2 1 0 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD (230Vac Input)

500mA 600mA 700mA 800mA 900mA 1050mA

POWER FACTOR (PF) CHARACTERISTIC
 Tcase at 85

THD

16 14 12 10
8 6 4 2 0
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD (277Vac Input)

500mA 600mA 700mA 800mA 900mA 1050mA

PF

1 0.95
0.9 0.85
0.8 0.75
0.7 0.65
0.6 0.55
0.5 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD (230Vac Input)

500mA 600mA 700mA 800mA 900mA 1050mA

PF

1 0.9 0.8 0.7
0.6 0.5 0.4
0.3 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD (277Vac Input)

500mA 600mA 700mA 800mA 900mA 1050mA

EFFICIENCY vs LOAD
LCM-40TW series possess superior working efficiency that up to 87% can be reached in field applications.  Tcase at 85

95 90 85 80 75 70 65 60 55 50
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD (230Vac Input)

500mA 600mA 700mA 800mA 900mA 1050mA

EFFICIENCY (%)

95 90 85 80 75 70 65 60 55 50
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD (277Vac Input)

500mA 600mA 700mA 800mA 900mA 1050mA

File Name:LCM-40TW-SPEC 2022-05-27

EFFICIENCY (%)

6.75

81.5

LCM-40TW 40W Constant Power Mode With Tunable White LED Driver

series

MECHANICAL SPECIFICATION

123.5

6.75

110

6.75

Case No.LCM-60A Unit:mm

2-4.2 6.75

68

39.3 7.8

65.5
7.8 2-4

Terminal Pin No. Assignment( TB1)

Pin No. Assignment

1

AC/L

2

AC/N

3

DA+/PUSH

4

DA-/N

 Terminal Pin No. Assignment(TB2)

Pin No. Assignment

1

+V

2

+V

3

-V1(C.W.)

4

-V2(W.W.)

1

2

3

TB1

4

1 TB2 2 3 4
54321
ON

LCM-40TW

15

tc

40

Bottom View
tc : Max. Case Temperature

23 4

Installation Manual
Please refer to : http://www.meanwell.com/manual.html

File Name:LCM-40TW-SPEC 2022-05-27



References

Corel PDF Engine Version 16.1.0.843