User Manual for VELBUS models including: vmb4ryld

VMB4RYLD datasheet

• manual push buttons on board for testing purposes • Velbus connection • 4 Modules wide on the DIN rail • firmware upgradeable through the Velbus system Specifications high inrush (80A) current relays are used relays type: 4 voltage outputs DC: 12A / 30VDC max. voltage outputs AC: 16A / 230VAC max. voltage outputs max. total current


File Info : application/pdf, 1 Pages, 99.65KB

PDF preview unavailable. Download the PDF instead.

vmb4ryld datasheet
VMB4RYLD datasheet
4-channel relay module with voltage outputs for DIN rail
4-channel relay module with 40 modes.

Features
· different operation modes: moment control, on/off control, start/stop timer, staircase lighting timer, non-restartable timer, switch-off delay, switch-on delay, start timer by releasing push button, timer with blinking effect, 2-way timer...
· free programmable timer functions (using Velbus Link software and USB/ RS232 interface (VMB1USB, VMB1RS or VMBRSUSB))
· 250 possible id addresses · manual push buttons on board for testing purposes · Velbus® connection · 4 Modules wide on the DIN rail · firmware upgradeable through the Velbus system

Protocol manuals for developers: available for download at https://github.com/velbus
VELBUS · VMB4RYLD Legen Heirweg 33 · 9890 Gavere · Belgium velbus.eu
1

Specifications
high inrush (80A) current relays are used

relays
max. total current power supply max. power consumption dimensions width standby current consumption

type: 4 voltage outputs DC: 12A / 30VDC max. voltage outputs AC: 16A / 230VAC max. voltage outputs 12A / 30VDC or 16A / 230VAC all channels combined 15±3VDC
250mA
90 x 71 x 58mm / 3.5 x 2.8 x 2.3"
4 DIN modules
30 mA



References

Adobe PDF Library 15.0 Adobe InDesign 14.0 (Windows)