Installation Guide for SAMSUNG models including: MIM-B14, MIM-B14, MIM-B14 External Controller, External Controller, Controller
MIM-B14 | MIM-B14 | Samsung Australia
File Info : application/pdf, 2 Pages, 3.53MB
DocumentDocumentEXTERNAL CONTROLLER INSTALLATION Parts PRODUCT NAME QUANTITY EXTERNAL CONTROLLER 1EA PCB CASE 1EA HARNESS WIRES 1EA for EACH WIRE SCREW 2EA SHAPE Installation 1. Fix PCB case( ) inside the indoor unit control box or at an appropriate position with screws ( ). 2. After fixing PCB cases, attach the external controller PCB. (See the following figure, Assembly Drawing) [figure, Assembly Drawing] SCREW PCB CASE WIRE WIRE or WIRE SCREW fixing Positions Screw fixing positions when necessary Align the case locking with the PCB locking 3. Connect 2 pin wire ( ) between the external controller PCB CN83 and indoor unit PCB EXT_CTRL connector(CN83). 4. Connect 4 pin wire ( ) between the external controller PCB CN81 and indoor unit PCB COMP/ERROR connector(CN81). 5. Connect 4 pin wire ( ) between the external controller PCB CN81 and indoor unit PCB R32 CHECK LAMP/ EXTERNAL ALARM connector(YELLOW). Refer to Indoor Unit manual. Installation option setting of indoor unit Indoor unit with DIP S/W Operation Specification according to Indoor Unit PCB installation option Set up WIRE NO. 1,2 3,4 5,6 K11 OFF COMP. Check OUTPUT STATE Error Check Signal Input (TIMER) K11 & K12 OFF Operating Check DB98-26202A-05 Indoor unit without DIP S/W Purpose Turn on/off the indoor unit via external contact control Control external heater Turn on/off the indoor unit via external contact control and control external heater (1*) 5, 6 INPUT DRY CONTACT DRY CONTACT 3, 4 OUTPUT 1, 2 OUTPUT THERMO ON/OFF or OPERATION ON/OFF External heater's Switch External heater's Switch ERROR STATUS (Normal Close) (*1) When the purpose is to use as external heater's on/off signal, monitoring signal for external contact control will not be outputted. Circuit diagram of external controller's output For turning on/off the indoor unit via external contact control AC LAMP For controlling external heater (On/Off) Circuit diagram for using external heater for the indoor units without hot water coil terminal AC Relay External Heater Detailed method about Installation option establishment refers to Indoor Unit manual. (External contact control setting: Refer to SGE14, SGE15 of 02 Series installation option External heater control setting: Refer to SEG15 of 02 Series Installation Option and SEG18 of 05 Series installation option)) Dry contact(no power source contact) must be be connected to the input terminal 5,6. When MIM-B14 is used for controlling external heater, its contact should not be connected directly to the load. (Only use as switch as shown in above diagram.) This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste. For correct disposal of this product, please visit http://www.samsung.com/weee.pdf This product is India RoHS compliant FR Cet appareil, ses accessoires, piles et cordons se recyclent À DÉPOSER À DÉPOSER EN MAGASIN EN DÉCHÈTERIE OU Points de collecte sur www.quefairedemesdechets.fr ! English Harici Kontrol Ünitesi KURULUMU Parçalar ÜRÜN ADI HARC KONTROL ÜNTES ELEKTRONK KART KUTUSU MIKTAR 1 ADET 1 ADET TEÇHZAT KABLOLARI HER KABLO ÇN 1 ADET VDA 2 ADET EKIL Kurulum 1. Elektronik kart kutusunu ( ) ç ünite kontrol kutusu içine veya uygun bir konuma vidalarla ( ) sabitleyin. 2. Elektronik kart kutusunu sabitledikten sonra, harici kontrol ünitesi kartini takin. (Aaidaki Montaj emasina bakin) [ekil, Montaj emasi] VDA PCB KASASI KABLO KABLO veya KABLO VDA sabitleme Konumlari Gerektiinde sabitleme konumlarini vidalayin Kasa kilidini elektronik kart kilidiyle hizalayin 3. 2 pinli kabloyu ( ) harici kontrol ünitesi karti CN83 ve iç ünite PCB EXT_CTRL konektörü (CN83) arasina balayin. 4. 4 pinli kabloyu ( ) harici kontrol ünitesi karti CN81 ve iç ünite PCB KOMP/HATA konektörü (CN81) arasina balayin. 5. 4 pinli kabloyu ( ) harici kontrol ünitesi karti CN81 ve iç ünite karti R32 LAMBA KONTROLÜ/HARC ALARM konektörü (SARI) arasina balayin. ç Ünite kilavuzuna bakin. ç ünitenin kurulum seçenei ayari DP Siviç'i olan ç Üniteler ç Ünite elektronik kart kurulum ayari KABLO NO. 1,2 3,4 5,6 ÇIKI DURUMU K11 KAPALI K11 ve K12 KAPALI Hata Bilgisi KOMP. Çaliiyor Bilgisi Çalima Bilgisi Sinyal Girii (ZAMANLAYICI) DP Siviç'i olmayan ç Üniteler Amaç Harici kontak kontrolü vasitasiyla iç üniteyi açin/ kapatin Harici isiticiyi kontrol edin Harici kontak kontrolü ve kontrol harici isiticisi vasitasiyla iç üniteyi açin/kapatin(*1) 5, 6 GR KURU KONTAK KURU KONTAK 3, 4 ÇIKI TERMO AÇIK/KAPALI ya da ÇALIMA AÇIK/KAPALI Harici isiticinin Anahtari Harici isiticinin Anahtari 1, 2 ÇIKI HATA DURUMU (Normal durum: kapali) (*1) Amaç harici isiticinin açik/kapali sinyalinin kullanimi olduunda, harici kontak kontrolü izleme sinyal çikii olmayacaktir. Harici Kontrol Ünitesi Elektronik Kartinin devre diyagrami Harici Kontak Kontrol Ünitesi vasitasiyla ç Ünitenin Açilmasi/Kapanmasi AC LAMBASI Harici Kontak Kontrol Ünitesi vasitasiyla Harici Isiticinin Kontrolü (Açma/Kapama) Sicak su bobin terminali olmadan iç üniteler için harici isiticiyi kullanmak için devre diyagrami Kurulum opsiyon kod ayari hakkinda ayrintili yöntem için ç Ünite kurulum kilavuzuna bakin. (Harici kontak kontrol ayari: Bkz. 02 Serisi kurulum opsiyon kodu SGE14, SGE15 Harici isitici kontrol ayari: Bkz. 02 Serisi kurulum opsiyon kodu SEG15 ve 05 Serisi kurulum seçenei SEG18) Kuru kontak (güç kaynai kontai yok) giri terminali 5,6'ya balanmalidir. Harici isiticiyi kontrol etmek için MIM-B14 kullanildiinda, kontai dorudan yüke balanmamalidir. (Yukaridaki diyagramda gösterildii gibi yalnizca anahtar olarak kullanin.) TÜRKÇE