Owner's Manual for SJE RHOMBUS models including: Installer Friendly Series Three Phase Simplex, Installer Friendly Series, Three Phase Simplex, Phase Simplex, Simplex
File Info : application/pdf, 2 Pages, 1.63MB
DocumentDocumentINSTALLER FRIENDLY SERIES® (IFS) THREE PHASE SIMPLEX Demand Dose or Timed Dose, Float or C-LevelTM Sensor Controlled System for Pump Control and System Monitoring 3 AD 6 2 1 4 B 9 5 10 Installer Friendly Series® CE F The IFS simplex control panel utilizes an innovative circuit board design to control one 208/240/480 VAC three phase pump in water and sewage applications. IFS panels feature an easy-to-use touch pad on inner door for programming and system monitoring. The panel configuration can be easily converted in the field to either a timed dose or demand dose. Available with the EZconnex® float system. The panel can utilize the C-LevelTM sensor for continuous level monitoring. It senses the level in the tank and sends a signal to the panel. Pump activation levels can be adjusted by using the panel touch pad. C-LevelTM CL40 sensor operating range is 3-39.9 inches (7.6-101.3 cm). C-LevelTM CL100 operating range is 3-99.5 inches (7.6-252.7 cm). TOUCH PAD FEATURES A. Level Status indicators illuminate when floats or set points are activated; alarm will activate if a float operates out of sequence B. HOA (Hand-Off-Automatic) buttons control pump mode with indication; Hand mode defaults to Automatic when stop level or redundant off level is reached C. Pump Run indicator will illuminate when pumps are called to run D. LED Display for system information including: level in inches or centimeters (C-LevelTM only), mode, pumps elapsed time (hh:mm), events (cycles), alarm counter, float error count, timed dose override counter (timed dose only), and ON/OFF times (timed dose only) E. NEXT push button toggles display F. UP and SET push buttons set pump ON/OFF times (timed dose only) and activation levels (C-LevelTM only) 7 11 8 12 Panel layout may vary with options. Reg. Cdn Pat. & TM Off C-LevelTM Sensor US Patent No. 8,336,385; 8,567,242; 8,650,949 COMPONENTS 1. Enclosure base measures 14 x 12 x 6 inches (35.56 x 30.48 x 15.24 cm); NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use) 2. Red LED beacon provides 360° visual check of alarm condition 3. Exterior Alarm Test/Normal/Silence switch allows horn and light to be tested and horn to be silenced in an alarm condition; alarm automatically resets once alarm condition is cleared 4. Motor protective switch provides adjustable overload, branch circuit protection and pump disconnect 5. IEC motor contactor controls pump by switching electrical lines 6. Multi-tap transformer (208/240/480 VAC primary) provides 120 VAC control alarm voltage or 600 VAC primary transformer 7. Float connection terminal block 8. Control Power indicator/fuse indicator light illuminates if control power is present in panel; alarm will activate if control fuse is blown 9. Alarm Power indicator/fuse indicator light illuminates if alarm power is present in panel 10. Large incoming power connection terminal block 11. Terminal block float wiring label 12. Ground lugs 13. Alarm horn provides audio warning of alarm condition (83 to 85 decibel rating) (Not shown) Note: Options, voltage, and amp range selected may change enclosure size and component layout. Note: Schematic/Wiring Diagram and Pump Specification Label are located inside the panel. 9500055J-WEB Rev 01/23 © 2020 SJE, Inc. All Rights Reserved. SJE Rhombus is a trademark of SJE, Inc. www.sjerhombus.com · Toll Free 888-342-5753 B.15 Installer Friendly Series® PRICING WORKSHEET INSTALLER FRIENDLY SERIES® THREE PHASE SIMPLEX - Demand or timed dose float controlled system for pump control and system monitoring. IFS CONTROL PANEL 5 MODEL TYPE 1 ALARM PACKAGE W ENCLOSURE RATING PUMP FULL LOAD AMPS FLOAT SWITCH APPLICATION CONTROL PANEL 3 IFS MODEL TYPE 3 5 Three Phase Simplex (includes Option 8AC as standard) $2,326.00 ALARM PACKAGE 3 1 Alarm Package (includes test/normal/silence switch, fuse, red light, & horn) Base ENCLOSURE RATING 3 W Weatherproof, NEMA 4X (engineered thermoplastic) Base 208/240/480V 600V 001 1.0 - 1.6 FLA 005 1.0 - 1.6 FLA Base 101 1.6 - 2.5 FLA 105 1.6 - 2.5 FLA Base 201 2.5 - 4.0 FLA 205 2.5 - 4.0 FLA Base PUMP FULL LOAD AMPS 301 4.0 - 6.3 FLA 401 6.0 - 10.0 FLA 305 4.0 - 6.3 FLA 405 6.0 - 10.0 FLA Base Base 511 9.0 - 14.0 FLA 515 9.0 - 14.0 FLA $59.00 611 13.0 - 18.0 FLA 615 13.0 - 18.0 FLA $59.00 621 17.0 - 23.0 FLA 625 17.0 - 23.0 FLA $72.00 701 20.0 - 25.0 FLA 705 20.0 - 25.0 FLA $72.00 H Floats - Pump Down (select Option 17 below) Base FLOAT SWITCH APPLICATION E EZconnex® Float Switch System (select Option 33 or 34 below) X No Floats - $102.00 - $102.00 C C-LevelTM Sensor (select Option 24 or 29) Select Option 3E and/or 4A & 4D for high water alarm and/or redundant off floats - $102.00 8AC OPTIONS (LISTED BELOW) IFS Three Phase Simplex Base Price $2,326.00 Alarm Package Enclosure Rating Pump Full Load Amps Float Switch Application Total Options TOTAL LIST PRICE NOTE: Pump down applications only. Industry practices suggest that a secondary device, such as a float switch, be used for redundant activation of the high level alarm and pump shut off when using the C-LevelTM sensor. OPTIONS 3A Alarm Flasher 3B Manual Alarm Reset DESCRIPTION LIST PRICE $66.00 $119.00 3E High Water Alarm Float (must also select Option 17) Only Available with Float Switch Application = C $34.00 4A Redundant Off (must also select Option 4D if floats are required) 4D Redundant Off Float (must also select Option 4A and Option 17) $72.00 $34.00 5A Thermal Cutout/Heat Sensor Auto Reset (for pumps with thermal switch leads) $51.00 5E Seal Failure Circuit and Red Indicator (2 Wire) 6A Auxiliary Alarm Contact, Form C $198.00 $51.00 3 8AC Display Board - Includes: ETM Counter, Events (Cycles) Counter, Alarm Counter (included as standard) $0.00 10E Lockable Latch - NEMA 4X $51.00 10G Lightning Arrestor $247.00 10K Anti-condensation Heater $124.00 11C Additional NEMA 1 Remote Alarm Panel (must also select Option 6A) $114.00 11D Additional NEMA 4X Remote Alarm Panel (must also select Option 6A) $368.00 16A 10' Cord in Lieu of 20' Cord (per Float) - $3.00 16B 15' Cord in Lieu of 20' Cord (per Float) - $2.00 16C 30' Cord in Lieu of 20' Cord (per Float) $6.00 16D 40' Cord in Lieu of 20' Cord (per Float) $18.00 OPTIONS DESCRIPTION LIST PRICE 17C Sensor Float® / Internally Weighted (per Float) - Mercury $13.00 17D Sensor Float® / Externally Weighted (per Float) - Mercury $15.00 17G SJE MilliAmpMasterTM / Pipe Clamp (per Float) - Mechanical $0.00 17H SJE MilliAmpMasterTM / Externally Weighted (per Float) - Mechanical $8.00 17J Sensor Float® / Pipe Clamp (per Float) - Mercury $6.00 24E C-LevelTM CL40 Sensor with 4' Vent Tube and 20' Cord $349.00 24F C-LevelTM CL40 Sensor with 4' Vent Tube and 40' Cord $384.00 24G C-LevelTM CL40 Sensor with 8' Vent Tube and 20' Cord $354.00 24H C-LevelTM CL40 Sensor with 8' Vent Tube and 40' Cord $390.00 24X No C-LevelTM CL40 Sensor $0.00 29A C-LevelTM CL100 Sensor with 10' Vent Tube and 20' Cord $359.00 29B C-LevelTM CL100 Sensor with 10' Vent Tube and 40' Cord $396.00 29X No C-LevelTM CL100 Sensor $0.00 33D EZconnex® 3-Port, 25', with 10' Floats (3) / Pipe Clamp $313.00 33E EZconnex® 3-Port, 50', with 10' Floats (3) / Pipe Clamp $355.00 33G EZconnex® 3-Port, 25', with 20' Floats (3) / Pipe Clamp $337.00 33H EZconnex® 3-Port, 50', with 20' Floats (3) / Pipe Clamp $379.00 34D EZconnex® 4-Port, 25', with 10' Floats (3) / Pipe Clamp, Sealing Plug $400.00 34E EZconnex® 4-Port, 50', with 10' Floats (3) / Pipe Clamp, Sealing Plug $454.00 34G EZconnex® 4-Port, 25', with 20' Floats (3) / Pipe Clamp, Sealing Plug $423.00 34H EZconnex® 4-Port, 50', with 20' Floats (3) / Pipe Clamp, Sealing Plug $476.00 EZconnex® mechanically-activated, narrow angle float switches with quick release connections B.16 www.sjerhombus.com · email: customer.service@sjeinc.com