Philips ProjectLine LED 3CCT Batten
Product Overview and Installation Guide
Key Features and Certifications
Brand: Philips
Product Type: LED 3CCT Batten
Certifications: CE, UKCA
Usage: Indoor Use
Power Supply: 220V - 240V, 50Hz / 60Hz
Technology: LED
Operating Temperature: Max 40°C, Min -20°C
Lifespan: L70 30,000 hours
Product Specifications
Type | CCT (K) | System Lumen (Lm) | Power (W) | Dimensions (LxWxH mm) | Weight (kg) |
---|---|---|---|---|---|
Projectline Batten 30cm 3xCCT 400lm | 3000/6500/4000 | 400/420/440 | 3.4 | 325x20x32 | 0.049 |
Projectline Batten 60cm 3xCCT 800lm | 3000/6500/4000 | 750/800/850 | 6.5 | 585x20x32 | 0.078 |
Projectline Batten 90cm 3xCCT 1200lm | 3000/6500/4000 | 1120/1200/1250 | 9.6 | 885x20x32 | 0.112 |
Projectline Batten 120cm 3xCCT 1600lm | 3000/6500/4000 | 1500/1600/1700 | 13.0 | 1185x20x32 | 0.144 |
Product Dimensions
Length (L) varies by model. Width: 20mm. Height: 32mm.
Installation and Usage Instructions
Trunking Methods
Trunking Method A
Utilizes a click-fit connection: Male plug part connects into a female socket. Affix the next system component only after linking. Maximum amount of linking: 8 pieces.
Trunking Method B
Requires a connector jack cable for linking. Maximum amount of linking: 8 pieces.
Connection Options
Control via Wall Switch
One end of the luminaire connects to the lamp, and the other end is wired directly into the mains via a 15cm cable.
Plug-in, Without Switch
One end of the luminaire connects to the lamp, and the other end connects to a mains socket via a 1.5m power cable.
Light Setting with Wall Switch (Memory Function)
The luminaire can retain its last used color temperature (CCT) setting.
- Default Setting: In 'Relax mode', the default is 3000K.
- 'Work mode': 6500K.
- 'Awake mode': 4000K.
To change CCT: Toggle the switch (on → off → on) within 6.4 seconds. This cycles through CCT options: 3000K → 6500K → 4000K → 3000K, depending on the last status.
Reset Function
To reset the luminaire to the default CCT of 3000K:
Toggle the switch (on → off → on → off → on) within 1.2 seconds.
Important Notes
CCT Switching Availability: The CCT switching function is only available when the luminaire is wired directly to the mains. If the luminaire is NOT wired directly to the mains, just plugged into the wall mains socket, only the default 3000K (Relax mode) CCT option is available.
Installation: Installation must be performed by a qualified electrician in accordance with the latest IEE electrical regulations or national requirements.
Component Replacement: The light source and control gear within this luminaire are not replaceable. If damaged, the entire luminaire must be replaced.
Environment: Luminaire must not be used or stored in corrosive environments containing hazardous materials such as sulphur, chlorine, or phthalates.
Water Protection: This luminaire has an IPX0 rating, meaning it is not protected against water ingress. Water entering the luminaire can cause electrical failure or unsafe conditions.
Flexible Cable: If the luminaire includes an external flexible cable, it must only be replaced by the manufacturer, their service agent, or a similarly qualified person.
Electrostatic Discharge (ESD): ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE DEVICES.