Navien NPF Hydro-furnaces

The leader in condensing technology brings the next level of comfort to forced-air heating.

Introducing the NPF Upflow and Horizontal High-Efficiency Hydro-Furnace

The NPF furnace offers advanced comfort through its innovative hydronic heating design.

NPF700-060U3BH Upflow

NPF700-060H3BH Horizontal

Technology that Delivers Next-Level Comfort

Unlike conventional gas furnaces where the combustion heat exchanger is in the conditioned airstream, the NPF heats water by burning gas in a sealed combustion heat exchanger, completely isolated from the airstream. This heated water is then pumped through a hydronic heat exchanger that gently transfers heat into the air. This unique method provides:

NPF Hydro-Furnace: A Closer Look

Conventional Furnace: Combustion heat exchanger is directly in the conditioned airstream, exposing air to high temperatures.

Navien NPF Hydro-Furnace: Our unique hydronic forced-air heating design keeps combustion in a separate, fully enclosed compartment for safe and quiet comfort.

The NPF features a durable stainless steel combustion heat exchanger located out of the airstream. A hydronic coil transfers heat from the water to the conditioned airstream at temperatures up to 150°F.

An Inside Look at the NPF Upflow

Our Stainless Steel Heat Exchanger and Burner

The heart of the NPF is its innovative stainless steel combustion heat exchanger, located out of the airstream. It heats water efficiently with 97% AFUE* and features ultra-low NOx compliance.

*Annual Fuel Utilization Efficiency.

The Elements of Next-Level Comfort

Quieter Operation

The NPF is one of the quietest furnaces in the industry, achieved through isolated combustion (outside the airstream), variable capacity operation, and intelligent blower ramping. Sound pressure levels are significantly lower compared to common household appliances.

Sound Pressure Levels (dBA) Comparison:

The NPF operates at significantly lower decibel levels, especially at minimum capacity.

Easier Operation

The intuitive EZ-Nav™ control panel puts control at your fingertips. Startup, configurations, and diagnostics are streamlined for easy operation. The NPF is compatible with single- or two-stage thermostats and integrates seamlessly with the latest thermostat and Indoor Air Quality (IAQ) technology.

Softer Heating

Our patented heat exchanger and hydronic coil gently heat the airstream, providing safe, even heating for a softer feel.

Greener Operation

The NPF is designed with the environment in mind, featuring high-efficiency ECM motor technology, 97% AFUE, and ultra-low NOx compliance. It qualifies for most regional incentives, lowers energy bills, and can potentially boost air conditioning and heat pump system efficiencies. Complies with SCAQMD Rule 1111.

Smarter Technology

The NPF's intelligent Variable Capacity System operates at 15%-100% capacity, optimizing air temperatures and airflow for maximum comfort and energy efficiency. It showcases adaptable technology integration and advanced control options, operating with standard or smart 1- or 2-stage thermostats. Self-diagnostic readouts facilitate easy system monitoring and maintenance.

NPF Variable Capacity Control System: Advanced Comfort for All Seasons

Heating Capacity and Efficiency

Items NPF700-060U3BH / NPF700-060H3BH NPF700-080U3BH / NPF700-080H3BH NPF700-100U5CH / NPF700-100H5CH
Heating (gas input) natural/ propane gas (BTU/h) Max heat 60,000 80,000 100,000
Min heat 9,000 11,000 14,000
AFUE (%) 97 97 97
Certified temperature rise range °F (°C) Max heat 45-75 (25-42)
Min heat 5-35 (3-19) 10-40 (6-22) 10-40 (6-22)
Burner control Modulating

Airflow Capacity and Blower Data

Items NPF700-060U3BH / NPF700-080U3BH / NPF700-100U5CH / NPF700-060H3BH / NPF700-080H3BH / NPF700-100H5CH
Certified external static pressure Heating Certified external static pressure 0.1" to 1.0" WC
Cooling
Airflow delivery range [CFM] (Rated ESP) Max heat 720-1,200 950-1,400 1,200-2,000
Min heat 350-1,200 450-1,400 400-2,000
Cooling 1,200 1,200 2,000
Nominal cooling capacity (TON) @400CFM 1.5-3.0 1.5-3.0 2.0-5.0
@350CFM 1.5-3.5 1.5-3.5 2.0-5.5
Circulator blower DxW 12" x 10" 12" x 10" 12" x 12"
Horsepower 1/2 1/2 1
Motor full load amps 7.6 7.6 11.0
Motor speed & type Variable, Electronically Commutated Motor (ECM)

Accessories

Dimensions

Dimensional drawings and measurements for NPF Upflow and Horizontal models are available.

Customer Support and Advanced Training

Navien provides extensive field support, webinars, and training events for builders, architects, and contractors. Their full-time customer support network offers quick answers to installation and operational questions.

Specifications

Items NPF700-060U3BH NPF700-080U3BH NPF700-100U5CH NPF700-060H3BH NPF700-080H3BH NPF700-100H5CH
Installation type Upflow Upflow Upflow Horizontal left Horizontal left Horizontal left
Venting type Forced draft direct vent or non-direct vent
Maximum vent length 2" 70 ft.
3" 140 ft.
Ignition Electronic spark ignition
Natural gas supply pressure (from source) 3.5" to 10.5" WC
Propane gas supply pressure (from source) 8.0" to 13.0" WC
Natural gas manifold pressure -0.01" to -0.02" WC
Propane gas manifold pressure -0.01" to -0.02" WC
Gas connection size 1/2" NPT
Water connection size 1/4" NPT
Condensate size 3/4" NPT
Materials Casing Corrosion resistant baked on pre-painted steel
Combustion heat exchanger Stainless steel
Hydronic heat exchanger Copper & aluminum
Venting Exhaust 2" or 3" PVC, CPVC, approved PP, 2" or 3" special gas vent type BH (Class III, A/B/C) 2" or 3" SS
Intake 2" or 3" PVC, CPVC, PP, 2" or 3" special gas vent type BH (Class III, A/B/C) 2" or 3" SS
Vent clearance 0" to combustibles
Safety devices Flame rod, ignition operation detector, water temperature high limit switch, high limit sensor for exhaust temperature, Vent Installation Detector (VID), water level sensor, burner high limit sensor, Pressure Relief Valve (PRV), leak sensor
Dimensions in (mm), WxDxH 17.5 x 31 x 34.5 (445 x 787 x 876) 17.5 x 31 x 34.5 (445 x 787 x 876) 21 x 31 x 34.5 (533 x 787 x 876) 34.5 x 31 x 17.5 (876 x 787 x 445) 34.5 x 31 x 17.5 (876 x 787 x 445) 34.5 x 31 x 21 (876 x 787 x 533)
Shipping weight lb (Kg) 145.0 (65.8) 145.0 (65.8) 167.6 (76.0) 145.0 (65.8) 145.0 (65.8) 167.6 (76.0)
Power supply 120V AC, 60 Hz
Max current (A) 10.9 10.9 14.3 10.9 10.9 14.3
Circuit breaker amps (A) 15 15 20 15 15 20
Wire size (AWG) 14 14 12 14 14 12

Warranty Information

Registered Furnaces Non-Registered Furnaces
Heat exchanger Lifetime* 20 Years**
Parts 10 Years* 5 Years**
Labor 1 Year* 1 Year**

*Limited warranties to original owner in residential applications with prompt registration.
**20-years heat exchanger, 5-year parts, and 1-year labor for non-registered furnaces.
Visit navieninc.com for complete warranty details and restrictions.

We are @Navieninc everywhere.

Navien Inc. | Navieninc.com | 800-519-8794
20 Goodyear, Irvine, CA 92618

Navien Canada, Inc. | Navieninc.ca | 800-519-8794
555 Hanlan Rd., Unit 7, Vaughan, ON L4L 4R8

Models: NPF700-060H3BH Horizontal, NPF700-060U3BH Upflow, NPF Series Condensing Hydronic Furnace, NPF Series, Condensing Hydronic Furnace, Hydronic Furnace, Furnace

File Info : application/pdf, 8 Pages, 7.51MB

PDF preview unavailable. Download the PDF instead.

475426 nvnnpf-brochure-2024

References

Adobe PDF Library 17.0 Adobe InDesign 20.0 (Macintosh)

Related Documents

Preview Navien High Efficiency Combi-Boilers: Endless Hot Water and Heating
Discover Navien's NCB-H and NFC-H series combi-boilers, offering high efficiency, high capacity, and compact design for comfortable home heating and endless hot water. Learn about their innovative features, energy savings, and warranty.
Preview Navien NCB300 Condensing Combi Boiler User's Information Manual
This manual provides essential information for the safe and efficient operation of the Navien NCB300 series condensing combi boilers. It covers installation, operation, troubleshooting, and warranty details.
Preview Navien NHB-110 Boiler CSD-1 Compliance Report
Manufacturer's and Installing Contractor's Report for the Navien NHB-110 high-efficiency condensing boiler, detailing ASME CSD-1 compliance, controls, and safety device specifications.
Preview Navien Combi-Boiler Quick Installation Guide: NCB Series
Concise guide for installing Navien NCB series combi-boilers, covering unpacking, mounting, gas and water connections, venting, electrical setup, and initial operation. Includes safety warnings and technical specifications.
Preview Navien NPE Condensing Water Heater Installation & Operation Manual
Comprehensive guide for the installation and operation of Navien NPE Condensing Water Heaters, covering safety, components, specifications, and troubleshooting.
Preview Navien NPE Condensing Water Heaters User's Information Manual
Comprehensive user's information manual for Navien NPE Condensing Water Heaters, covering safety, operation, maintenance, and troubleshooting for models NPE-180A2, NPE-210A2, NPE-240A2, NPE-180S2, NPE-210S2, and NPE-240S2.
Preview Navien NPE Series Tankless Water Heater: Quick Installation Guide
A concise guide for installing Navien NPE series tankless water heaters, covering safety, location, mounting, connections, venting, and operation. Includes model numbers NPE-180A2, 210A2, 240A2, 150S2, 180S2, 210S2, 240S2.