Circuit identification stickers for use on cover directory labels to identify branch circuits |
PSDS |
DE5 |
Door Lock Kit: Use with convertible indoor load center covers (Series S-1) |
PK6FL |
DE3A |
Filler Plates: Fills opening in covers if twistout is removed in error |
HOMFP |
DE3C |
Filler Plates: Fills main circuit breaker opening in convertible load centers (100-125 A) |
QOM1FP |
DE3A |
Filler Plates: Fills main circuit breaker opening in convertible load centers (150-225 A) |
QOM2FP |
DE3A |
Generator Circuit Breaker Interlock Kit: For use on "S" Series NEMA 1 and NEMA 3R load centers. Interlocks a QOM1 2P main circuit breaker of a load center (100-125 A) with a Homeline 2P (15-125 A) branch circuit breaker |
HOMCRBGK1C |
DE3D |
Generator Circuit Breaker Interlock Kit: For use on "S" Series NEMA 1 and "S1" Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150-225 A) with a Homeline 2P (15-125 A) branch circuit breaker |
HOMCGK2C |
DE3D |
Generator Circuit Breaker Interlock Kit: For use on "S2" and "S3" Series NEMA 3R QOM2 load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150-225 A) with a Homeline 2P (15-125 A) branch circuit breaker |
HOMRBGK2C |
DE3D |
Ground Bar Kits: Ground Bar Assembly - 3 connectors |
PK3GTA1 |
DE3A |
Ground Bar Kits: Ground Bar Assembly - 4 connectors |
PK4GTA1 |
DE3A |
Ground Bar Kits: Ground Bar Assembly - 7 connectors |
PK7GTA1 |
DE3A |
Ground Bar Kits: Ground Bar Assembly - 9 connectors |
PK9GTA1 OBS |
DE3A |
Ground Bar Kits: Ground Bar Assembly - 15 connectors |
PK15GTA1 |
DE3A |
Ground Bar Kits: Ground Bar Assembly - 19 connectors |
PK18GTA1 |
DE3A |
Ground Bar Kits: Ground Bar Assembly - 23 connectors |
PK23GTA1 |
DE3A |
Ground Bar Kits: Ground Bar Assembly - 27 connectors |
PK27GTA1 |
DE3A |
Ground Bar Kits: Standard PK15GTA with a 1–4/0 Al/Cu Lug |
PK15GTA |
DE3A |
Ground Bar Kits: Standard PK18GTA with a 1–4/0 Al/Cu Lug |
PK18GTAL |
DE3A |
Ground Bar Kits: Ground Bar Pack - PK9GTA, PK9GTA & Lug |
PKGTALP1 |
DE3A |
Ground Bar Kits: Ground Bar Pack - PK9GTA, PK18GTA & Lug |
PKGTALP2 |
DE3A |
Ground Bar Kits: Ground Bar Pack - PK15GTA, PK18GTA & Lug |
PKGTALP3 |
DE3A |
Ground Bar Kits: Insulator Kit for PK7GTA through PK27GTA |
PKGTAB |
DE3A |
Handle Padlock Attachment: For padlocking main circuit breakers in convertible load center, "OFF" (50–125 A) |
QOM1PA |
DE2E |
Handle Padlock Attachment: For padlocking main circuit breakers in convertible load center, "OFF" (100–225 A) |
QOM2PA |
DE2E |
Neutral Bonding Screw: For use on all Homeline and QO 125A convertible main load centers |
4028344850K |
DE5 |
Neutral Bonding Screw: For use on QO 150A-225A convertible main load centers |
4028345850K |
DE5 |
Neutral / Ground Lugs: Field-installed for 14–2 AWG Al or 14–4 AWG Cu wire |
LK70AN |
DE3B |
Neutral / Ground Lugs: Field-installed for 6–2/0 AWG Al/Cu wire |
LK100AN |
DE3B |
Neutral / Ground Lugs: Field-installed for 14–2/0 AWG Al/Cu wire |
LK125AN |
DE3B |
Neutral / Ground Lugs: Field-installed for 4 AWG to 300 kcmil Al/Cu wire. Use in Series S, 150-225A QO load center or S03 and below, 150-225A HOM load center |
LK225AN |
DE3A |
Neutral / Ground Lugs: Field-installed for 4 AWG–300 kcmil Al/Cu wire. Use in Series S04, 150–225 A HOM load center |
LK225ANHOM |
DE3A |
Replacement Cover Directory Label: 1 through 42 numbered universal replacement directory label for load center covers |
LSDL |
DE5 |
Retaining Kit for Breakers Used as Back-fed Mains: Secures circuit breaker to interior when used as a back-fed main. For HOM612L100F/S, RB and HOM48L125GC, GRB load centers |
HOM1RK |
DE3C |
Retaining Kit for Breakers Used as Back-fed Mains: Secures ONE circuit breaker right side of interior when used as a back-fed main For 100–125 A convertible main load centers, Series S01 and S02 |
HOM4RK2LA |
DE3C |
Retaining Kit for Breakers Used as Back-fed Mains: Secures ONE circuit breaker right side of interior when used as a back-fed main For 150–225 A convertible main load centers, Series S01 and S02 |
HOM4RK2HA OBS |
DE3C |
Retaining Kit for Breakers Used as Back-fed Mains: Secures circuit breaker to interior when used as a back-fed main For 2P 150–200 A circuit breakers |
HOM5RK |
DE3C |
Service Entrance Barriers: QO/Homeline 1Ø 100–125 A QOM1 convertible main load centers |
PKSB1LA |
DE3A |
Service Entrance Barriers: QO/Homeline 1Ø 150–225 A QOM2 convertible main load centers |
PKSB1HA |
DE3A |
Service Entrance Barriers: Homeline back-fed main breaker applications |
PKSB1HOMBF |
DE3A |