User Guide for westermo models including: Viper-012, Unmanaged EN 50155 Switch, Viper-012 Unmanaged EN 50155 Switch
prieš 4 dienas — The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind are made in relation to the accuracy and ...
Read this manual completely and gather all information on the product. ... EN 50121-4/IEC 62236-4, Railway signaling and telecommunications apparatus.
Read this manual completely and gather all information on the product. ... not installed and used in accordance with the instructions, may cause harmful ...
File Info : application/pdf, 16 Pages, 1.19MB
DocumentDocumentw w w. we s t e r m o. c o m Viper-012 Unmanaged EN 50155 Switch 2 6641-22410 General information Legal information The contents of this document are provided "as is". Except as required by applicable law, no warranties of any kind are made in relation to the accuracy and reliability or contents of this document, either expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Westermo reserves the right to revise this document or withdraw it at any time without prior notice. Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused. More information about Westermo can be found at www.westermo.com 6641-22410 3 Safety and Regulations Warning signs are provided to prevent personal injury and/or damages to the product. The following levels are used: Level of warning Description Consequence personal injury Indicates a potentially Possible death or hazardous situation major injury Consequence material damage Major damage to the product WARNING Indicates a potentially Minor or moderate hazardous situation injury Moderate damage to the product CAUTION NOTICE Provides information in order to avoid misuse of the product, confusion or misunderstanding No personal injury Minor damage to the product Used for highlighting No personal injury general, but important information Minor damage to the product NOTE 4 6641-22410 Before installation: Read this manual completely and gather all information on the product. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this product. SAFETY DURING INSTALLATION The product must be installed by qualified service personnel and built in to an apparatus cabinet or similar, where access is restricted to service personnel only. During installation, ensure a protective earthing conductor is first connected to the protective earthing terminal (only valid for metallic housings). Westermo recommends a cross-sectional area of at least 4 mm2. Upon removal of the product, ensure that the protective earthing conductor is disconnected last. HAZARDOUS VOLTAGE Do not open an energized product. Hazardous voltage may occur when connected to a power supply. PROTECTIVE FUSE The power supply wiring must be sufficiently fused. It must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations. This product has no internal fuse and should be connected via an external fuse for protection. 6641-22410 REDUCE THE RISK OF FIRE To reduce the risk of fire, use only telecommunication line cords with a cable diameter of AWG 26 or larger. Regarding power cable dimensions, see Interface Specifications. 5 HOT SURFACE Be aware that the surface of this product may become hot. When it is operated at high temperatures, the external surface may exceed Touch Temperature Limit according to the product's relevant electrical safety standard. ELECTROSTATIC DISCHARGE (ESD) Prevent electrostatic discharge damages to internal electronic parts by discharging your body to a grounding point (e.g. use a wrist strap). 6 6641-22410 Care recommendations Follow the care recommendations below to maintain full operation of product and to fulfill the warranty obligations: · Do not drop, knock or shake the product. Rough handling above the specification may cause damage to internal circuit boards. · Use a dry or slightly water-damp cloth to clean the product. Do not use harsh chemicals, cleaning solvents or strong detergents. · Do not paint the product. Paint can clog the product and prevent proper operation. If the product is used in a manner not according to specification, the protection provided by the equipment may be impaired. If the product is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo technical support. Product disposal This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it. It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help to reduce hazardous substances and prevent potential negative consequences to both environment and human health, which could be caused by inappropriate disposal. Declaration of Conformity Hereby, Westermo declares that this product is in compliance with applicable EU directives and UK legislations. The full declaration of conformity and other detailed information is available at www.westermo.com/support/product-support. 6641-22410 7 Agency approvals and standards compliance Type Approval / Compliance EMC EN 61000-6-1, Immunity residential environments EN 61000-6-2, Immunity industrialokokvironments EN 61000-6-3, Emission residential environments EN 61000-6-4, Emission industrial environments EN 50121-3-2, Railway applications Rolling stock apparatus EN 50121-4/IEC 62236-4, Railway signaling and telecommunications apparatus Environmental EN 61373, Railway applications Rolling stock equipment. Shock and vibration tests IEEE 1478, Environmental conditions for transit rail car electronic equipment EN 50124-1, Railway applications Insulation coordination EN 50155, Railway applications Electronic equipment used on rolling stock IEC 60068-2-27, (shock 100g, 6 ms, halfsine) EN 45545-2, Fire safety standard FCC Part 15.105 Notice: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ... Reorient or relocate the receiving antenna ... Increase the separation between the equipment and receiver ... Connect the equipment into an outlet on a circuit different from that to which the receiver is connected ... Consult the dealer or an experienced radio/TV technician for help. 8 6641-22410 Type tests and environmental conditions Environmental phenomena Basic standard Description Test levels ESD EN 61000-4-2 Enclosure Contact: ±6 kV Air: ±8 kV Fast transients EN 61000-4-4 Power port ±5 kV Signal ports ±2 kV Earth port ±1 kV Surge EN 61000-4-5 Power port L-E: ±2 kV, 12, 9 F, 1.2/50 s L-L: ±1 kV, 2, 18 F, 1.2/50 s L-E: ±2 kV, 42, 0.5 F, 1.2/50 s L-L: ±2 kV, 42, 0.5 F, 1.2/50 s L-E: ±8.4 kV, 100, 0.05/0.1 s L-L: ±8.4 kV, 100, 0.05/0.1 s Ethernet ports L-E: ±2 kV, 2 Power frequency magnetic field EN 61000-4-8 Enclosure 300 A/m; 0, 16.7, 50, 60 Hz Pulsed magnetic field EN 61000-4-9 Enclosure 300 A/m Radiated RF immunity EN 61000-4-3 Enclosure 20 V/m @ (80 MHz 2.7 GHz) 1 kHz sine, 80% AM 10 V/m @ (2.7 6 GHz) 1 kHz sine, 80% AM Conducted RF immunity EN 61000-4-6 Power port 10 V, 80% AM, 1 kHz; (0.15 80) MHz Ethernet ports 10 V, 80% AM, 1 kHz; (0.15 80) MHz Earth port 10 V, 80% AM, 1 kHz; (0.15 80) MHz Radiated RF emission CISPR 16-2-3 Enclosure Class B (30 6000 GHz) ANSI C63,4 (FCC Part 15) Class B (30 6000 GHz) Conducted RF emission CISPR 16-2-1 Power port Class B Ethernet ports Class B Dielectric strength EN 60950-1 Power port to all other ports 1.5 kV ACrms, 50 Hz, 1 min Fast Ethernet ports 1.5 kVACrms, 50 Hz, 1 min to all other ports Environmental Temperatures EN 60068-2-1 Operating 40 to +70°C (40 to +158°F)* EN 60068-2-2 Storage and transport 50 to +85°C (58 to +185°F) Humidity EN 60068-2-30 Operating 5 to 95% relative humidity Storage and transport 5 to 95% relative humidity Altitude Operating 2 000 m / 70 kPa Service life Operating 15 years MTBF 636,000 hours MIL-C217F2, GB, 25°C (+77°F) Vibration IEC 60068-2-6 Non operating long 7.9 m/s² (RMS) 5 150 Hz (sine) life simulation IEC 60068-2-64 Operating (random) 1 m/s² (RMS) 5 150 Hz Shock IEC 60068-2-27 Operating 10 g, 30 ms, 20 g, 11 ms, 100 g, 6 ms Bump IEC 60068-2-27 Operating 10 g, 11 ms Enclosure Zinc Fire enclosure Dimension W x H x D With connectors See "Dimensions" chapter for details Weight 1.4 kg Degree of protection EN 60529 Enclosure IP67** Cooling Convection * Refer to "Safety" section ** Provided all connectors are connected with IP67 cabling or fitted with protective caps (delivered with the unit), tightened to the specified torque 6641-22410 9 Description Designed for harsh industrial environments The Viper-012 is a unmanaged rugged Ethernet switch designed for applications with severe operating conditions and extreme environments. With an ultra robust design, sealed to IP67 and vibration resistant to and exceeding on-board rail standards this unit is ideal for situations where mechanical stress, moisture, condensation, dirt or continuous vibrations could adversely affect the function of standard Ethernet switches. Fully approved for onboard rolling stock, this unit can be deployed in e.g. trains, trams, busses, mining trucks, army vehicles and drilling rigs. Product model 3641-0540 Viper-012 unmanaged switch. 10 6641-22410 Interface specifications DC, Power port Rated voltage 24 to 110 VDC Operating voltage 16.8 to 143 VDC (14.4 to 154 VDC for 100 ms) Rated current Viper-x12: Max 350 mA @ 24 V, max 90 mA @ 110 V Viper-x12-T3G: Max 550 mA @ 24 V, max 120 mA @ 110 V Rated frequency DC Inrush current, I²t 1 mA²s @ 24 V and 6 mA²s @ 110 V Startup current* 535 mA @ 24 V 145 mA @ 110 V Polarity Reverse polarity protected Redundant power input Yes Isolation to 1500 VAC rms to all other Connection 4 pin male M12 A-coded connector, use Westermo cable 3146-1106 for 1.5 m 3146-1107 for 5 m Connector size M12, recommended cable area 0.5 mm² recommended (minimum 0.25 mm²), cable dimensions depend on choice of M12 connector * External supply current capability for proper start-up X1-X12 Ethernet ports Electrical specification Data rate Duplex Circuit type Transmission range Isolation to Connection Shielded cable Conductive housing Number of ports IEEE std 802.3. 2005 Edition 10 Mbit/s, 100 Mbit/s, manual or auto Full or half, manual or auto Viper-x12: X1-X12: TNV-1 Viper-x12-T3G: X1-X3, X5-X7, X9-X11: TNV-1 X4, X8, X12: SELV Up to 150 m with CAT5e cable or better Viper-x12: 1500 VAC rms to all other ports Viper-x12-T3G: X1-X3, X5-X7, X9-X11: 1500 VAC rms to other ports X4, X8, X12: 500 VAC rms to other ports 4-pin M12 D-code, auto MDI/MDI-X, use e g Westermo cable 3146-1100 M12-M12 1 m 3146-1101 M12-M12 5 m 3146-1103 RJ45-M12 1 m 3146-1104 RJ45-M12 5 m Not required, but recommended in severe electromagnetic environments Yes 12 6641-22410 11 M12 Torque 0.6±0,1 Nm / 0,45±0,1 lbft Location of interface ports and LED Ethernet connection TX LED indicators For Westermo internal use only X1 SRV 1 X2 SRV 2 X3 DC X4 X5 X9 X6 X10 X7 X11 X8 X12 Earth connection Power connection 12 6641-22410 Power Connector Pin-out Pin number Signal No 1 +DC1 2 1 No 2 +DC2 No 3 -COM 3 4 No 4 -COM LED Indicators LED DC X1 to X12 Status OFF GREEN RED OFF GREEN GREEN FLASH YELLOW Description Unit has no power. Power OK on DC1 and DC1. Power failure on DC1 or DC2. No Link. Link established. Data traffic indication. Port alarm and no link. * SRV 1 & SRV 2 only for internal use by Westermo staff X1 * SRV 1 X2 SRV 2 X3 DC X4 X5 X9 X6 X10 X7 X11 X8 X12 M12 Torque 0.6±0,1 Nm / 0,45±0,1 lbft 6641-22410 13 Wall mounting There are four 6 mm bore holes intended for mounting the unit. The unit can be mounted vertical or horizontal. Use four M5 screws with 12 mm washer on a flat and stable surface. Connection of cables Recommended tightening torque for the M12 connectors: 0.6 Nm Note that unused connectors must be covered by a protective cap (delivered with the unit), tightened to the specified torque, in order to fulfill the specified ingress protection code. Removal Disconnect all cables and unscrew the unit from the wall. Time For Replacement < 15 minutes Cooling This unit relies on convection cooling. Make sure that it is installed so that the ambient temperature is within the specified temperature range, e.g. by avoiding obstruction of the airflow around the unit. 14 6641-22410 Dimensions Measurements are stated in millimeters. Rev Description 01 Created Date 130225 Designer PaPu Approved ToDu 36,7 ±1 7,4 ±0,5 22 ±1 11 ±1 M5 6,7 ±1 3 5 174 ±1 164 ±1 142 ±1 7 5 110 111 65,4 ±1 54,1 ±1 73,5 72 48,8 48 24 23,3 0 1,5 14 0 6,5 -0,5(4x) Pos No Quantity Description Designation / Dimension Material / Remark Denomination Viper-12-series Designer PaPu Approved Date ToDu 130225 Scale 1:1 Sheet 1(1) Dimensional Drawing Drawing No. 6001-0001-U-01 Status Approved © 2010 Westermo Teleindutri AB All rights reserved 100 ±1 56 ±0,5 23 ±1 1 6 1 0 6641-22410 15 Westermo · Metallverksgatan 6, SE-721 30 Västerås, Sweden Tel +46 16 42 80 00 Fax +46 16 42 80 01 E-mail: info@westermo.com www.westermo.com REV. C 6641-22410 2022-08 Westermo Network Technologies AB, Sweden