GIMA Aluminum Patient Lifter

PROFESSIONAL MEDICAL PRODUCTS

Model: LW06301 (GIMA 43460)

Multilingual Titles: SOLLEVATORE IN ALLUMINIO ALUMINUM PATIENT LIFTER LÈVE-PERSONNE EN ALUMINIUM ELEVADOR DE ALUMINIO PARA PACIENTES

Important Safety Information

All serious accidents concerning the medical device supplied must be reported to the manufacturer and the competent authority of the member state where the registered office is located.

Summary of Contents

1 SAFETY WARNINGS

1.1 General warnings

The instruction manual is an integral part of the supply and must be carefully stored and accessible for immediate consultation by transfers, the owner, safety managers, users, and maintenance workers. It provides guidance on correct use, technical characteristics, and security precautions.

If the device is received with transport damage, it must not be used. Contact technical support for verification and inspection.

The device must be used by people physically capable of controlling the mass of the device or person transported. The conductor must be fully aware of this manual's contents.

Before each use, always check the efficiency of parts, brakes, and all safety features. The conductor must hold both hands firmly on the handlebar.

Requirements for use:

Assembly and adjustments must be carried out exclusively by authorized personnel.

Never lift the device with the passenger on board.

The device cannot be used exposed to water splash or bad weather conditions.

Drivers and patients must ensure long scarves or slow dresses do not become entangled, as this can be a source of danger.

Before using, ensure the weight of the person transported does not exceed the maximum allowed value, indicated on the lifting arm.

The lift is intended for lifting and transferring disabled people from bed to wheelchair and vice versa. It must not be used to transport people from one room to another. It is a gentle aid and should only be used for its designed purposes.

1.2 Symbols Used

The following pictograms can be found in the manual:

The manufacturer reserves the right to make changes to the product and its instruction manual without prior notice. The manufacturer is relieved of liability for damage resulting from misuse, unauthorized modifications, unauthorized spare parts, exceptional events, or non-compliance with instructions.

2 UNPACK

When using a trolley to move the packaged product, take care to avoid tipping injuries.

Open the packaging and take out its contents with caution, being careful not to damage it.

After unpacking, ensure the device is not damaged. Any damage must be reported to the carrier within 24 hours.

2.1 Advices on environmental protection

The packaging material is 100% recyclable. For disposal, follow local regulations. Keep packaging material (plastic bags, polystyrene parts, etc.) out of reach of children as a potential source of danger.

In accordance with Art. 13 of Legislative Decree No 151 of 25 July 2005 concerning electrical and electronic equipment and waste disposal:

3 DESCRIPTION

The electric lifter allows a disabled person to be lifted by a linear actuator to transfer them from bed to wheelchair and vice versa. The operation uses a cloth harness equipped with a hooking belt.

3.1 Illustration

The lifter consists of the following parts:

The hand controller features:

4 ASSEMBLY

The device must be fitted and tested by qualified personnel before use. These operations must be carried out by qualified personnel.

4.1 Frame Assembly

  1. Take all parts from the packaging and locate the lifter body on a clean, flat surface.
  2. Remove the locking bolt and raise the main frame until it reaches the base socket.
  3. Fix the locking bolt and ensure it is firmly locked.
  4. Release the transport strap of the lifting arm.

These operations must be carried out by qualified personnel.

5 TECHNICAL CHARACTERISTICS

6 USE INTENDED

6.1 Use Expected

The device is authorized for daily use only if all security elements and functional parts are efficient. The lift is intended to lift and transfer disabled people from bed to wheelchair and vice versa. It is a gentle aid and should not be used for purposes other than those for which it was designed. The aid can only operate on flat surfaces with a stable bottom. Use is exclusively as described in this manual; read these instructions carefully to become familiar with the device's functionality.

6.2 Prohibition of Use

6.3 Residual Risks

7 USE

Before daily use, always check the status and overall efficiency of the aid and battery charge.

7.1 Battery charge

The control unit has a "female" socket for battery charging on the battery chassis. Charging indications are provided.

If the device is intended to remain unused for a long-term (over one month), recharge the battery every month.

7.2 Lifting function

7.3 Safety ring functionality

In case of potential malfunctions of the electrical group or critical situations (e.g., unexpected shutdowns due to low battery), the height of the lifting arm and its barbell can be adjusted manually by acting on the appropriate safety ring located at the end of the linear actuator.

OPERATING MODE OF THE RING SYSTEM:

The red knob (a) at the top of the actuator can be manually moved downwards (from fig. 1 to fig. 2 position). This allows manual ascent or descent of the lifting arm. The lift is equipped with safety against accidental crushing by the arm; if the arm encounters an obstacle during motorized downward movement, it will move to the position referred to in figure 2 and automatically cease downward thrust.

7.4 Use of Slings

For harness use, follow this procedure:

Open the lift base: The base spread is operated by a special pedal system at the back. Press pedal (A) to open, press pedal (B) to close.

8 ROUTINE MAINTENANCE

The lifter requires ordinary maintenance like any product to remain in perfect condition. Daily remove food leftovers, hair, and dust using a domestic vacuum cleaner. The following table outlines recommended maintenance frequencies.

FrequencyTask
6 monthsCleaning metal parts
Proceed with cleaning these parts according to use and necessity
6 monthsCleaning plastic parts
Proceed with cleaning these parts according to use and necessity
6 monthsCleaning wheels
Proceed with cleaning these parts according to use and necessity
2 monthsLubrication
Depending on the use and need
1 yearGeneral Check:
Check the wheels and tighten the bolts
Check the braking system
Check paint for rust or chipping
Check plastic parts are intact and their state of wear, consider replacement if requested
Check if the electric motors are working properly and lubricate the screws
6 months (if transferred to third parties or restored)Battery:
Check that the battery charging time is not too long; otherwise, contact the authorized technical support service.
If transferred to third parties or restoredDisinfection:
[Qualified Personnel Only] Disinfection substances must be used by specifically qualified personnel only. The disinfection of this device must be carried out by specialized centers according to the dispositions made by the competent health authority. For more information, contact the authorized technical support service.

8.1 Cleaning metal parts

Painted metal parts can be cleaned with commercial sprays for domestic use, but avoid those containing alcohol or solvents, which can discolor or damage the paint. Chrome parts can be cleaned with normal household products and dried well. Do not use jets or splashes of water.

8.2 Cleaning plastic parts

For cleaning plastic parts, use a common plastic detergent for commercial use, following the instructions and contraindications provided with the product. Avoid solvent or alcohol products. Do not use jets or splashes of water.

8.3 Cleaning wheels

Periodically clean the wheels, depending on the environment of use. Remove any solid parts, threads, or hair that may wedge themselves in the gum or wrap around the hub, making rotation difficult. Clean the mechanism of the snares using a toothbrush.

9 TROUBLE SHOOT

[Qualified Personnel Only] When operations are represented by this symbol, they must be carried out by qualified personnel only.

ComponentInconvenienceSolution
WheelSqueaking while movingCleaning the wheels
Lubricate the wheels
Replace the wheels
BatteryThe battery is lowCheck the battery charge; if necessary, provide charging.
The security button is pressedUnlock the button.
BatteryConnection cables (actuator/remote control/control unit) are not properly connectedCheck electrical connections.
Check the functionality of electrical components.
BatteryThe battery is not charged normally, takes too long, or does not happen comprehensively.Verify the electrical integrity of the control unit.
Check the integrity and connection modes of the connection between machine and network.
BatteryThe battery has a limited charge.

10 WARRANTY

The product is covered by a legal 12-month warranty starting from the delivery date, against any kind of manufacturing defect.

Throughout the warranty duration, maintenance is guaranteed at the manufacturer's expense if the problem is a manufacturing defect. Warranty is void if routine maintenance is neglected.

Warranty does not cover parts subject to normal wear (e.g., wheels) or damages from:

Shipping and packaging for warranty repair are at the expense of the dealer or manufacturer. Warranty does not entitle the customer to demand compensation.

Spare parts are available for 5 years from the product's discontinuation date.

If problems are detected, immediately inform the authorized dealer, providing problem details from the device's data decal and filling out the defect and failure reporting form. The customer, after arrangements with the dealer, will handle shipment for warranty repair. Technical intervention during warranty will be by the manufacturer to confirm manufacturing defects.

This manual must be kept by the owner and stay with the device for guarantee exercise.

Warranty starts from the delivery date.

Expected lifespan

The average lifespan of the Electric Lifter is 5 years. Lifespan may increase or decrease depending on frequency of use and maintenance.

11 ACCESSORIES

LW06401: Economy Sling

LW06407: Universal Sling

SYMBOL LEGEND

[Manufacturer]Manufacturer[EC REP]Authorized representative in the European community
[Date of Manufacture]Date of manufacture[CE MDR Compliant]Medical Device compliant with Regulation (EU) 2017/745
[Product Code]Product code[Medical Device]Medical Device
[Lot Number]Lot number[UDI]Unique device identifier
[Caution: Read Instructions]Caution: read instructions (warnings) carefully[WEEE Disposal]WEEE disposal
[Read Instructions]Leggere le istruzioni per l'uso (Italian)[Imported By]Imported by

GIMA WARRANTY TERMS

The Gima 12-month standard B2B warranty applies.

Disposal

Disposal: The product must not be disposed of with other domestic waste. Users must dispose of this equipment by bringing it to a specific recycling point for electric and electronic equipment.

Models: LW06301 GIMA 43460, LW06301 Aluminum Patient Lifter, LW06301, Aluminum Patient Lifter, Patient Lifter, Lifter

File Info : application/pdf, 9 Pages, 1.50MB

PDF preview unavailable. Download the PDF instead.

M43460EN

References

Adobe InDesign 18.2 (Windows) Adobe PDF Library 17.0

Related Documents

Preview GIMA Safety Belt - User Manual and Specifications
Detailed user manual and technical specifications for the GIMA Safety Belt, including usage instructions, material details, storage, cleaning, and model information for B2, B4, B8, B9, B10, B11, B12.
Preview GIMA UP-7000 Multi-Parameter Patient Monitor User Manual
Comprehensive user manual for the GIMA UP-7000 Multi-Parameter Patient Monitor, detailing its features, operation, safety guidelines, and technical specifications for professional medical use.
Preview GIMA Sterile Insulin Pen Needles: Instructions for Use, Specifications, and Safety
Comprehensive guide to GIMA sterile insulin pen needles (34G-28G). Learn about specifications, usage, safety precautions, contraindications, and storage for single-use insulin injection.
Preview GIMA Pressure Activated Safety Lancets (PA) - Medical Device for Capillary Blood Sampling
Information on GIMA Pressure Activated Safety Lancets (Model PA), a sterile, single-use device for capillary blood sampling. Includes intended use, instructions, warnings, storage, and disposal.
Preview GIMA Vacuum Splint Kit (AS-04) - Professional Medical Product Instructions
Comprehensive instructions and specifications for the GIMA Vacuum Splint Kit (Model AS-04), a professional medical device for immobilization. Includes usage, storage, cleaning, and safety information.
Preview GIMA Safety Belt - Patient Restraint Device
GIMA offers a range of safety belts designed to secure patients and prevent them from sliding or falling from stretchers. Available in various models with different lengths and materials, these belts are essential for patient safety during transport.
Preview Gima Single-Use MC-INTOSH Blade N. 3 - Product Information
Product details for Gima's single-use MC-INTOSH blade, model LS-78130 (GIMA 34376), including medical device information, usage warnings, and manufacturer details.
Preview GIMA Medical Furniture Catalog: Comprehensive Range of Hospital and Healthcare Equipment
Explore GIMA's extensive catalog of high-quality medical furniture, including patient lifters, hospital beds, examination couches, trolleys, and specialized chairs. Discover innovative solutions designed for comfort, safety, and efficiency in healthcare settings.