Generac Guardian Series Residential Standby Generators
8/11 kW Air-Cooled Gas Engine
Product Overview
The Generac Guardian Series offers reliable residential standby generators designed to provide backup power during utility outages. These air-cooled gas engine units feature advanced technology for performance and durability.
What's Included
- True Power™ Electrical Technology
- Two Line LCD Multilingual Digital Evolution™ Controller (Supports English, Spanish, French, Portuguese)
- Two Transfer Switch Options: 50 Amp Pre-Wired Switch or 200 Amp Service Rated Switch (See Page 4 for Details)
- Electronic Governor
- External Main Circuit Breaker
- System Status & Maintenance Interval LED Indicators
- Sound Attenuated Enclosure
- Flexible Fuel Line Connector
- Composite Mounting Pad
- Natural Gas or LP Gas Operation
- 5 Year Limited Warranty
- Capability to be installed within 18 inches (457 mm) of a building*
*Installation clearance requires location away from doors, windows, and fresh air intakes, and adherence to local codes.
Key Features
- Innovative Design & Prototype Testing: Generac's commitment to rigorous testing ensures superior performance and reliability. This includes component, reliability, environmental, destruction, and life testing, adhering to applicable CSA, NEMA, EGSA, and other standards.
- True Power™ Electrical Technology: Delivers superior harmonics and a sine wave form with less than 5% Total Harmonic Distortion for utility-quality power. This ensures confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVAC systems.
- Test Criteria: Units are rigorously tested, including Prototype Tested, System Torsional Tested, NEMA MG1-22 Evaluation, and Motor Starting Ability.
- Solid-State, Frequency Compensated Voltage Regulation: This advanced system provides optimized fast response to changing load conditions and maximum motor starting capability by electronically torque-matching surge loads to the engine. It offers digital voltage regulation at ±1%.
- Single Source Service Response: Generac's extensive dealer network provides comprehensive parts and service support for the entire unit.
- Generac Transfer Switches: Designed for long life and reliability, Generac offers integrated transfer systems and controls for complete system compatibility.
Standby Power Ratings
Model Series | Fuel Type | Standby Power Rating |
---|---|---|
006237-0, 006245-0 (Steel - Bisque) | 8 kW 60 Hz | 8,000 Watts (LP) / 7,000 Watts (NG) |
006437-1, 006438-2, 006439-1 (Steel - Bisque) | 11 kW 60 Hz | 11,000 Watts (LP) / 10,000 Watts (NG) |
006720-0 (Aluminum - Grey) | 11 kW 60 Hz | 11,000 Watts (LP) / 10,000 Watts (NG) |
Note: CUL certification applies to unbundled units and units packaged with pre-wired switches. Units packaged with the Smart Switch are UL certified in the USA only.
Generator Visual
The product features an image of a Generac Guardian Series air-cooled gas engine standby generator, model 006720-0, presented in a grey aluminum enclosure.
Engine Features and Benefits
- Generac (OHVI) Design: Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life.
- "Spiny-lok" Cast Iron Cylinder Walls: Rigid construction and added durability provide long engine life.
- Electronic Ignition/Spark Advance: Ensures smooth, quick starting every time.
- Full Pressure Lubrication System: Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Features up to a 2 year/200 hour oil change interval.
- Low Oil Pressure Shutdown System: Prevents catastrophic engine damage due to low oil.
- High Temperature Shutdown: Prevents damage due to overheating.
Generator Features and Benefits
- Revolving Field: Allows for a smaller, lighter unit that operates 25% more efficiently than a revolving armature generator.
- Skewed Stator: Produces a smooth output waveform for compatibility with electronic equipment.
- Displaced Phase Excitation: Maximizes motor starting capability.
- Automatic Voltage Regulation: Regulates output voltage to ±1%, preventing damaging voltage spikes.
- UL 2200 Listed: For your safety.
Transfer Switch Features
- Fully Automatic: Transfers your vital electrical loads to the energized source of power.
- Pre-wired, Color-Coded Conduits (Pre-wired switches only): Ensures the easiest, trouble-free installation.
- Remote Mounting: Mounts near your existing distribution panel for simple, low-cost installation.
Evolution™ Controls Features
- Auto/Manual/Off Illuminated Buttons: Selects operating mode and provides easy, at-a-glance status indication.
- Two-Line LCD Multilingual Display: Provides easily visible logs of history, maintenance, and events (up to 50 occurrences).
- Sealed, Raised Buttons: Offers a smooth, weather-resistant user interface for programming and operations.
- Utility Voltage Sensing: Constantly monitors utility voltage, with setpoints for 60% dropout and 80% pick-up.
- Generator Voltage Sensing: Constantly monitors generator voltage for clean power delivery.
- Utility Interrupt Delay: Prevents nuisance engine start-ups, adjustable from 2-1500 seconds.
- Engine Warm-up: Ensures the engine is ready to assume the load (approx. 5 seconds).
- Engine Cool-down: Allows the engine to cool before shutdown (approx. 1 minute).
- Programmable Exerciser: Runs the generator for 12 minutes every other week (or weekly/monthly) to prevent oil seal drying and maintain readiness, offering flexibility and lower fuel costs.
- Smart Battery Charger: Delivers charge only when needed, adapting to outdoor air temperature.
- Main Line Circuit Breaker: Protects the generator from overload.
- Electronic Governor: Maintains a constant 60 Hz frequency.
Unit Features
- SAE Weather Protective Enclosure: Ensures quiet operation and protection against weather, withstanding winds up to 150 mph. Features a hinged key locking roof panel for security, lift-out front for maintenance access, and durable electrostatically applied textured epoxy paint.
- Enclosed Critical Grade Muffler: Mounted inside the unit to prevent injuries.
- Small, Compact, Attractive: Designed for easy, eye-appealing installation, as close as 18 inches away from a building.
Installation System
- 1 ft (305 mm) Flexible Fuel Line Connector: Absorbs generator vibration when connected to rigid pipe.
- Composite Mounting Pad: Eliminates the need to pour a concrete pad unless required by local municipalities.
Specifications
Generator Specifications
006237-0, 006245-0 (8 kW) | 006437-1, 006438-2, 006439-1 (11 kW) | |
---|---|---|
Rated Maximum Continuous Power Capacity (LP) | 8,000 Watts* | 11,000 Watts* |
Rated Maximum Continuous Power Capacity (NG) | 7,000 Watts* | 10,000 Watts* |
Rated Voltage | 240 | 240 |
Rated Maximum Continuous Load Current – 240 Volts (LP/NG) | 33.3/29.2 | 45.8/41.7 |
Total Harmonic Distortion | Less than 5% | Less than 5% |
Main Line Circuit Breaker | 35 Amp | 50 Amp |
Phase | 1 | 1 |
Number of Rotor Poles | 2 | 2 |
Rated AC Frequency | 60 Hz | 60 Hz |
Power Factor | 1.0 | 1.0 |
Battery Requirement (not included) | Group 26R, 12 Volts and 525 CCA Minimum | Group 26R, 12 Volts and 525 CCA Minimum |
Unit Weight (lb/kg) | 360/163.3 | 407/184.6 |
Dimensions (L x W x H) in/mm | 48 x 25 x 29 / 1218 x 638 x 732 | 48 x 25 x 29 / 1218 x 638 x 732 |
Sound output in dB(A) at 23 ft (7 m) at normal load** | 62 | 63 |
Exercise Duration | 12 min | 12 min |
*Maximum wattage and current are subject to factors like fuel content, ambient temperature, altitude, and engine condition. Power decreases with altitude and higher temperatures.
**Sound levels are taken from the front of the generator. Other sides may have higher levels depending on installation.
Engine Specifications
GENERAC OHVI | GENERAC OHVI V-TWIN | |
---|---|---|
Type of Engine | GENERAC OHVI | GENERAC OHVI V-TWIN |
Number of Cylinders | 1 | 2 |
Displacement | 410 cc | 530 cc |
Cylinder Block | Aluminum w/ Cast Iron Sleeve | Aluminum w/ Cast Iron Sleeve |
Valve Arrangement | Overhead Valve | Overhead Valve |
Ignition System | Solid-state w/ Magneto | Solid-state w/ Magneto |
Governor System | Electronic | Electronic |
Compression Ratio | 9.5:1 | 9.5:1 |
Starter | 12 Vdc | 12 Vdc |
Oil Capacity Including Filter | Approx. 1.5 qt/1.4 L | Approx. 1.7 qt/1.6 L |
Operating rpm | 3,600 | 3,600 |
Fuel Consumption (Natural Gas) | 1/2 Load: 78 ft³/hr (2.21 m³/hr) Full Load: 121 ft³/hr (3.43 m³/hr) | 1/2 Load: 124 ft³/hr (3.51 m³/hr) Full Load: 195 ft³/hr (5.52 m³/hr) |
Fuel Consumption (Liquid Propane) | 1/2 Load: 31.6 (0.87) [3.29] ft³/hr (gal/hr) [l/hr] Full Load: 51.6 (1.42) [5.37] ft³/hr (gal/hr) [l/hr] | 1/2 Load: 42.8 (1.18) [4.45] ft³/hr (gal/hr) [l/hr] Full Load: 70 (1.92) [7.28] ft³/hr (gal/hr) [l/hr] |
Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet: 3.5-7" water column (7-13 mm mercury) for natural gas, 10-12" water column (19-22 mm mercury) for LP gas.
Controls Specifications
2-Line Plain Text Multilingual LCD Display | Simple user interface for ease of operation. |
Mode Buttons: Auto, Manual, Off | Automatic Start on Utility failure (Auto). Start with starter control (Manual). Stops unit (Off). |
Ready to Run/Maintenance Messages | Standard |
Engine Run Hours Indication | Standard |
Programmable Start Delay | Adjustable 2-1500 seconds (factory default 5 seconds). |
Utility Voltage Loss/Return to Utility | Monitors utility voltage, adjustable settings (e.g., brownout). |
Exerciser/Exercise Set Error Warning | Programmable exerciser runs generator for 12 minutes every other week (or weekly/monthly). |
Run/Alarm/Maintenance Logs | Stores up to 50 events. |
Engine Start Sequence | Cyclic cranking: max five times at factory set intervals. |
Starter Lock-out | Starter cannot re-engage until 5 seconds after engine has stopped. |
Smart Battery Charger | Charges battery only when needed, adapts to temperature. |
Charger Fault/Missing AC Warning | Standard |
Low Battery/Battery Problem Protection | Standard |
Automatic Voltage Regulation | With Over and Under Voltage Protection. |
Under-Frequency/Overload/Stepper Overcurrent Protection | Standard |
Safety Fused/Fuse Problem Protection | Standard |
Automatic Low Oil Pressure/High Oil Temperature Shutdown | Standard |
Overcrank/Overspeed/rpm Sense Loss Shutdown | Standard |
High Engine Temperature Shutdown | Standard |
Internal Fault/Incorrect Wiring Protection | Standard |
Common External Fault Capability | Standard |
Field Upgradable Firmware | Standard |
Switch Options
Pre-Wired Switch Features
- Electrically operated, mechanically-held contacts for fast, positive connections.
- Rated for all classes of load, 100% equipment rated (inductive and resistive).
- 2 pole, 250 VAC contactors.
- 30 millisecond transfer time.
- Single coil design.
- Main contacts are silver plated or silver alloy to resist welding and sticking.
- NEMA 1 (indoor rated) enclosure is standard.
- Includes a 30-foot (9.1 meter) pre-wired whip to connect to the provided 5-foot pre-wired whip and external connection box.
- Includes a 2-foot (0.61 meter) pre-wired whip, color-coded to connect into the existing electrical panel.
50 Amp Pre-Wired Switch Specifications
006237-0 (8 kW) | 006437-1 (11 kW) | |
---|---|---|
Model | 006237-0 (8 kW) | 006437-1 (11 kW) |
No. of Poles | 2 | 2 |
Current Rating (Amps) | 50 | 50 |
Voltage Rating (VAC) | 250 | 250 |
Utility Voltage Monitor (Fixed) | Pick-up: 80% Dropout: 60% | Pick-up: 80% Dropout: 60% |
Return to Utility* | approx. 15 sec | approx. 15 sec |
Exerciser weekly for 12 minutes* | Standard | Standard |
UL Listed | Standard | Standard |
Total of Pre-wired Circuits | 10 | 12 |
No. 15 A 120 V | 3 | 5 |
No. 20 A 120 V | 3 | 3 |
No. 20 A 240 V | 1 | 1 |
No. 30 A 240 V | 1 | 1 |
No. 40 A 240 V | - | 1 |
No. 50 A 240 V | - | 1 |
Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250 Volts | 10,000 | 10,000 |
*Function of Evolution Controller
50 Amp Switch Mechanical Dimensions
Height | Width | Depth | |||||
---|---|---|---|---|---|---|---|
H1 | H2 | H3 | W1 | W2 | W3 | ||
in | 18.5 | 22.5 | 22 | 10.5 | 15.4 | 14.4 | 3.8 |
mm | 470 | 571.8 | 558.8 | 266.7 | 392 | 366 | 97.5 |
Note: The 50 amp switch is flush mountable. H1 and W1 refer to mounting hole spacing. H2 and W2 are cover dimensions. H3 and W3 are the enclosure dimensions without cover.
Wire Ranges
Conductor Lug | Neutral Lug | Ground Lug |
---|---|---|
1/0 - #14 | 2/0 - #14 | 2/0 - #14 |
Service Rated Switch Features (Available on 11 kW model only)
- Electrically operated, mechanically-held contacts for fast, clean connections.
- Rated for all classes of load, 100% equipment rated (inductive and resistive).
- Service equipment rated, dual coil design.
- Rated for both aluminum and copper conductors.
- NEMA/UL 3R aluminum outdoor enclosure.
- Main contacts are silver plated or silver alloy to resist welding and sticking.
200 Amp Open Transition Service Rated Switch Specifications
006438-2 (11 kW) | |
---|---|
Model | 006438-2 (11 kW) |
No. of Poles | 2 |
Current Rating (Amps) | 200 |
Voltage Rating (VAC) | 250 |
Utility Voltage Monitor (Fixed) | Pick-up: 80% Dropout: 60% |
Return to Utility* | approx. 13 sec. |
Exerciser weekly for 12 minutes* | Standard |
UL Listed | Standard |
Enclosure Type | NEMA/UL 3R |
Withstand Rating (Amps) | 22,000 |
Lug Range | 250 MCM - #6 |
*Function of Evolution Controller
200 Amp Service Rated Switch Dimensions
Height | Width | Depth | |||
---|---|---|---|---|---|
H1 | H2 | W1 | W2 | ||
in | 27.24 | 30.0 | 11.4 | 13.5 | 7.09 |
mm | 692.0 | 762.4 | 289.0 | 343.0 | 180.0 |
Diagrams showing the 50 Amp Switch and 200 Amp Service Rated Switch dimensions are described textually above.
Available Accessories
- Mobile Link™ (Model #006463-3): Allows remote status checking of the generator via internet connection from a PC or smart device, with notifications via e-mail or text message.
- 26R Wet Cell Battery (Model #005819-0): Recommended battery for starting all air-cooled standby products (excluding PowerPact®).
- Cold Weather Kit (Model #006212-0): Required for temperatures below 32°F (0°C) to maintain optimal battery and oil temperatures. Includes a battery warmer and oil filter heater with thermostats.
- Auxiliary Transfer Switch Contact Kit (Model #005621-0): Allows the transfer switch to lock out a single large electrical load. Not compatible with 50 amp pre-wired switches.
- Fascia Base Wrap Kit (Model #005839-0): Snaps together around the generator base, providing a sleek appearance and protection from rodents and insects by covering lifting holes.
- Paint Kit (Model #005703-0): Includes necessary paint to properly maintain or touch-up a generator enclosure if scratched or damaged.
- Scheduled Maintenance Kit (Models #006482-0 - 8 kW / #006483-0 - 11 kW): Provides all hardware for complete routine maintenance on a Generac automatic standby generator.
- Wireless Remote Monitor (Model #006664-0): Completely wireless and battery-powered, providing instant status information without leaving the house. Not compatible with CorePower or EcoGen systems.
- Smart Management Module (50 Amps) (Model #006873-0): Used with the Automatic Transfer Switch to increase power management capabilities and flexibility.
Generator Dimensions and UPCs
Dimensions shown are approximate and for reference. Refer to the installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
Left Side View: Shows dimensions of 637.6 mm [25.1 in] (height) and 642 mm [25.3 in] (width).
Front View: Shows dimensions of 1218 mm [47.9 in] (height) and 1226 mm [48.3 in] (width).
Model | UPC |
---|---|
006245-0 | 696471062458 |
006237-0 | 696471062373 |
006439-1 | 696471064391 |
006437-1 | 696471064377 |
006438-2 | 696471064384 |
006720-0 | 696471067200 |