Whirlpool French Door Bottom Mount Refrigerator
Model Number: WRMF3636R*
Location Requirements
A WARNING
Explosion Hazard
Keep flammable materials and vapors, such as gasoline, away from appliance. Use nonflammable cleaner. Failure to do so can result in death, explosion, or fire.
IMPORTANT: This appliance is intended for household and similar applications such as staff kitchen areas, farm houses, hotels, motels, bed and breakfast environments, and catering applications.
Ventilation Requirements: To ensure proper ventilation, allow 1/2" (1.25 cm) of space on each side and at the top, and 1" (2.54 cm) behind the refrigerator. Allow extra space at the back for water line connections if equipped with an ice maker. For installations next to a fixed wall, allow a minimum of 2 1/2" (6.3 cm) on the hinge side for door swing.
Temperature Range: This refrigerator is designed for locations with temperatures between 55°F (13°C) and 110°F (43°C). The optimal room temperature for performance and energy efficiency is between 60°F (15°C) and 90°F (32°C). Avoid installing near heat sources like ovens or radiators.
Product Dimensions
Dimension | Measurement |
---|---|
Model Number | WRMF3636R* |
Model Size | 24.5 cu ft (693.7 L) |
Height - Overall "A" | 70 1/8" (178.1 cm) |
Height - Top of Cabinet "B" | 68 5/8" (174.3 cm) |
Depth - Doors Open 90° "C" | 48" (121.9 cm) |
Depth - Drawer Open "D" | 52 3/8" (133.0 cm) |
Depth - With Handles "E" | 34 5/8" (87.9 cm) |
Depth - Without Handles "F" | 32 1/8" (81.6 cm) |
Depth - Cabinet Only "G" | 29" (73.6 cm) |
Width - Cabinet "H" | 35 5/8" (90.5 cm) |
Width - Doors Open 90° "I" | 41" (104.1 cm) |
Electrical Requirements
A WARNING
Electrical Shock Hazard
Plug into a grounded 3-prong outlet. Do not remove the ground prong. Do not use an adapter or extension cord. Failure to follow these instructions can result in death, fire, or electrical shock.
Grounding Method: A 115 V, 60 Hz AC-only, 15 A or 20 A fused, grounded electrical supply is required. It is recommended to use a separate circuit for the refrigerator. Use an outlet that cannot be turned off by a switch. Do not use an extension cord.
IMPORTANT: If connected to a GFCI outlet, nuisance tripping may occur, leading to loss of cooling. Dispose of food if quality is affected by such tripping.
Note on Power Off: Before installation, cleaning, or replacing a light bulb, turn cooling off or set the control to Off. For digital controls, press the minus sign until dashes appear. Disconnect from electrical source. Reconnect and turn cooling on after completion.
Water Pressure Requirements
Water Supply: A cold water supply with pressure between 35 psi and 120 psi (241 kPa and 827 kPa) is required for the water dispenser and ice maker. Consult a licensed plumber if you have questions about water pressure.
Note on Low Pressure: If water pressure is below requirements, water dispenser flow may decrease, or ice cubes may be hollow or irregular.
Reverse Osmosis Water Supply: The water pressure from a reverse osmosis system to the water inlet valve must be between 35 psi and 120 psi (241 kPa and 827 kPa). If the reverse osmosis system is connected to your home cold water supply, the pressure to the system must be a minimum of 40 psi to 60 psi (276 kPa to 414 kPa).
Dimensions are for planning purposes only. Refer to Installation Instructions for complete details. Specifications are subject to change without notice.