CITYMULTI TPLFYP018FM140A
18,000 BTU/H 22” X 22” 4-WAY CEILING CASSETTE
Brand: Mitsubishi Electric | Model: TPLFYP018FM140A
General Features
- Square edge, sleek design
- 3D i-see Sensor™ available as an option
- Improved installation features*
- Occupancy detection*
- Energy saving features*
- Improved occupant comfort
- Four fan speed settings including auto-fan
- Individual vane settings
- 2' x 2' size matches size of many ceiling tiles
- Corner-pocket design for simplified installation
- Built-in condensate lift mechanism designed to provide up to 33" of lift
- Ventilation air intake supported
*Requires a PAR-33MAA-J controller
Specifications
Specification | Unit Type | System (TPLFYP018FM140A) | |
---|---|---|---|
Cooling capacity (Nominal)¹ | BTU/H | 18,000 | |
Heating capacity (Nominal)¹ | BTU/H | 20,000 | |
Power source | Voltage, Phase, Hertz | 208/230V, 1-phase, 60 Hz | |
Power Consumption | kW (Cooling) | 0.04 | |
kW (Heating) | 0.04 | ||
Current | A (Cooling) | 0.4 | |
A (Heating) | 0.35 | ||
MCA | A | 0.5 | |
Maximum Overcurrent Protection (MOCP) | A | 15 | |
External finish | Galvanized steel sheet | ||
External Dimensions | In. [mm] | 22-7/16 x 22-7/16 x 8-3/16 [570 x 570 x 208] | |
Net weight | Lbs [kg] | 31.3 [14.2] | |
Heat exchanger | Cross fin (Aluminum fin and copper tube) | ||
Fan | Type x quantity | Turbo fan x 1 | |
Airflow rate | CFM | 315-390-460 | |
Motor type | DC motor | ||
Motor Output | kW | 0.05 | |
Motor FLA | A | 0.4 | |
Sound pressure level (Measured in anechoic room) | dB(A) | 33-39-43 | |
Air filter | Type | PP honeycomb fabric (long life type) | |
Refrigerant | R410A | ||
Diameter of refrigerant pipe (O.D.) | Liquid (High Pressure) | In. [mm] | 1/4 [6.35] Flare |
Gas (Low Pressure) | In. [mm] | 1/2 [12.7] Flare | |
Diameter of drain pipe | In. [mm] | O.D. 1-1/4 [32] |
NOTES: ¹Cooling / Heating capacity indicated at the maximum value at operation under the following conditions: Cooling | Indoor: 80° F (26.7° C) DB / 67° F (19.4° C) WB; Outdoor 95° F (35° C) DB. Heating | Indoor: 70° F (21.1° C) DB; Outdoor 47° F (8.3° C) DB / 43° F (6.1° C) WB.
Indoor Unit Accessories
- Control Interface: BACnet® and Modbus® Interface (PAC-UKPRC001-CN-1), Connector cable for remote display (PAC-SA88HA-EP), IT Extender (PAC-WHS01IE-E), kumo station® for kumo cloud® (TAC-WHS01HC-E), Thermostat Interface (PAC-US444CN-1), Thermostat Interface (PAC-US445CN-1)
- Remote Sensor: Remote Temperature Sensor (PAC-SE41TS-E), Terminal Signal Adapter (PAC-IT51AD-E), Terminal Signal Adapter (PAC-IT52AD-E)
- Wired Remote Controller: Deluxe Wired MA Remote Controller¹ (TAR-40MAAU), Simple MA Remote Controller¹ (TAC-YT53CRAU-J), Smart ME Remote Controller - Backlit touchscreen (TAR-U01MEDU-K), Touch MA Controller¹ (TAR-CT01MAU-SB), kumo touch™ RedLINK™ Wireless Controller (MHK2)
- Wireless Remote Controller: Wireless MA Receiver (PAR-SR32MA-E), Wireless MA Remote Controller (TAR-FL32MA-E), Wireless Receiver (PAR-WSC009FA-E), Wireless Remote Controller (PAR-SL101A-E), Wireless Signal Receiver Panel (PAR-SR4LU-E)
- Condensate: Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] (X87-721), Blue Diamond (MicroBlue) Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H (X86-003), Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H (COMBI)
- Control Interface: CN24 Relay Kit (CN24RELAY-KIT-CM3), Remote Operation Adapter+ (PAC-SF40RM-E)
- i-see Sensor® Panel: 3D i-see Sensor® Corner Panel (PAC-SF1ME-E), Grille with 3D i-see Sensor® (TLP-18FAEU)
NOTES: ¹PAC-SF40RM-E (Unable to use with wireless remote controller)
Indoor Unit Dimensions and Installation
The indoor unit is designed for ceiling cassette installation and features specific dimensions and clearance requirements.
Unit Dimensions:
The main unit dimensions are approximately 22-7/16 inches (570 mm) in width and depth, and 8-3/16 inches (208 mm) in height.
Installation Features:
- Airflow: Features air intake holes (e.g., 12-7/32" or 310mm) and air outlet holes (e.g., 12-3/4" or 324mm). The unit is designed with a 2' x 2' size to match standard ceiling tiles.
- Connections:
- Refrigerant Pipe (O.D.): Liquid (High Pressure) 1/4" [6.35] Flare; Gas (Low Pressure) 1/2" [12.7] Flare.
- Drain Pipe: VP-25 connection, 1-1/4" [32] O.D.
- Mounting: Suspension bolt pitch is designed for ceiling installation, with typical dimensions around 20-21/32" (525 mm) to 22-11/16" (576 mm) for the ceiling hole.
- Installation Clearances: Minimum maintenance space is required around the unit. For example, a minimum of 17-23/32" (450mm) is recommended on the sides and a minimum of 19-11/16" (500mm) on the entire periphery for servicing.
- Other Features: Includes fresh air intake, terminal blocks for power supply and remote controller connections, and space for i-see Sensor panels.
The unit is certified by Intertek (ETL Listed US).