Listing Constructional Data Report (CDR)

Report Number: 190430012GZU-001

Issued: 22-Jul-2019 | Revised: None

1.0 Reference and Address

Applicant Manufacturer
Shenzhen Sonoff Technologies Co., Ltd.
Room 1001, 10F, Building 8, Lianhua Industrial Park, Longyuan Road, Longhua District, Shenzhen, Guangdong
China
Contact: Annie Li; Jerry Shi
Phone: 86-13392865705; 86-13380305412
Email: annie.li@itead.cc; jerry.shi@itead.cc
Shenzhen Yindao Micro-electronics Co.,Ltd
7F, Block 5, Jingsheng Industrial Park, Huawang Road, Dalang Street, Longhua Dustrict, Shenzhen, Guangdong 518109
China
Contact: Jie Zhou; Dihua Wu
Phone: 86-13923732756; 86-18002501871
Email: yindao.2007@163.com;

2.0 Product Description

Product: Wi-Fi Smart Wall Socket

Brand Name: Sonoff

Description: The product is a flush-type receptacle employing one 5-15R outlet with a cover plate. It operates via the 'eWelink' app, allowing wireless ON/OFF control of the power live wire and functioning as a signal repeater. The device can also be controlled by pressing the sensor switch button on the product.

Model: IW100TPB

Ratings: Input: AC 120V, 60Hz; Output: 15A, Max. 1800W

3.0 Product Photographs

Photo 1: Front view of model IW100TPB, showing the receptacle outlet and a control button.

Photo 2: Back view of model IW100TPB, showing the connection terminals.

Photo 3: Outside view of model IW100TPB, showing the product's external casing.

Photo 4: Internal view of model IW100TPB, revealing the internal circuitry and components.

Photo 5: Internal view of model IW100TPB, showing the main circuit board and other internal components.

Photo 6: Close-up view of internal components of model IW100TPB, with various components labeled.

Photo 7: Close-up view of internal components of model IW100TPB, showing the main circuit board with various electronic components and markings.

4.0 Critical Components

Item No. Name Manufacturer/ Trademark Type / Model Technical Data and Securement Means Mark(s) of Conformity
1,2EnclosureSABIC INNOVATIVE PLASTICS US LLC940(f1)PC, minimum thickness 1.5 mm, V-0, 120°C, HWI 3, HAI 3, CTI 2. Refer to Illustration 2, 3 of Section 7.0 for details.UR
2Cover plateSABIC INNOVATIVE PLASTICS US LLC940(f1)PC, minimum thickness 2.0 mm, V-0, 120°C, HWI 3, HAI 3, CTI 2. Refer to Illustration 4 of Section 7.0 for details.UR
3TerminalVariousVariousCopper & Brass, rested on PCB, refer to Illustration 7 of Section 7.0 for details.NR
4Socket contactNingbo Shengfa Copper Co., LtdC3064Phosphor copper. CU>58%. Refer to Illustration 5, 6 of Section 7.0 for details.NR
5Internal wireVariousVariousMin. 22AWG, 80°C, 300V, VW-1cURus, cETLus recognised
6PCBJIANGXI ZHONG XIN HUA ELECTRONICS INDUSTRY CO LTDZXH-2V-0, 130°CUR
7FuseVarious XC Electronics (shenzhen) Corp., Ltd4TMinimum V-0, 130℃; 1A, 250VUR
8Varistor (MOV)Hongzhi Enterprises Ltd.HEL10D471K300VAC, 125°C In=3kAcURus
9X-capacitorShantou High-New Technology Dev. Zone Songtian Enterprise Co., Ltd.MPXMax. 0.047 uF, 275 Vac, 110°C, X2 typecURus
10Y-capacitorShantou High-New Technology Dev. Zone Songtian Enterprise Co., Ltd.CD221KY1, 0.22nF, 250V, 125°CcURus
11RelaySHENZHEN GOLDEN ELECTRICAL APPLIANCES CO.,LTDGH-1A-5L15A, 125V, 85°C, GP LOADcURus
12TransformerZhejiang Fanhar Electronics Co., Ltd.W11-1A2STLE-H15A, 125V, 85°C, GP LOADcURus
12aMagnet Wire (Not shown)Shenzhen Xinchuanglong Electronics Co., Ltd. GridXCL-EE10-5V0.5A-CR1511-2.7MHClass A. Refer to Illustration 10 of Section 7.0.NR
12aMagnet Wire (Not shown)DONGGUAN RUNZHI ELECTRONIC TECHNOLOGY CO. LTD.EE10-2.7mHClass A. Refer to Illustration 11 of Section 7.0.NR
12aMagnet Wire (Not shown)SHANTOU SHENGANG ELECTRICAL INDUSTRIAL CO LTDXUEW/155 QA-x/155155°C(for XCL-EE10-5V0.5A-CR1511-2.7MH)UR
12aMagnet Wire (Not shown)DONG GUAN YIDA INDUSTRIAL CO LTDXUEW/130130 (for EE10-2.7mH)UR
12bTriple Insulation Wire (Not shown)SHENZHEN DARUN SCIENCE AND TECHNOLOGY CO LTDDRTIW-B130°C (for XCL-EE10-5V0.5A-CR1511-2.7MH)UR
12bTriple Insulation Wire (Not shown)Shanghai Hengyi Special Cable Co., Ltd.HY-F130°C (for EE10-2.7mH)UR
12cBobbin (Not shown)CHANGSHU SOUTH-EAST PLASTIC CO LTDPF2A5-151JV-0, 150°C (for XCL-EE10-5V0.5A-CR1511-2.7MH)cURus
12cBobbin (Not shown)CHANG CHUN PLASTICS CO LTDT375JV-0, 150°C (for EE10-2.7mH)cURus
12dTeflon tube (Not shown)FLUO TECH INDUSTRIES CO LTDTFT300V, 200°C (for XCL-EE10-5V0.5A-CR1511-2.7MH)UR
12dTeflon tube (Not shown)DONGGUAN CITY CHANGJIE METALS & PLASTIC PRODUCTS CO LTDCJ-TT-T300V, 200°C (for EE10-2.7mH)UR
12eInsulation tape (Not shown)SUZHOU MAILADUONA ELECTRIC MATERIAL CO LTDJY312#130°C (for XCL-EE10-5V0.5A-CR1511-2.7MH)UR
12eInsulation tape (Not shown)JINGJIANG YAHUA PRESSURE SENSITIVE GLUE CO LTDPZ130°C (for EE10-2.7mH)UR
12fVarnish(Not shown)ZHUHAI CHANGXIAN NEW MATERIALS TECHNOLOGY CO LTDE962130°C (for XCL-EE10-5V0.5A-CR1511-2.7MH)UR
12fVarnish(Not shown)QUALIPOLY CHEMICAL CORP1032BIH130°C (for EE10-2.7mH)UR

5.0 Critical Unlisted CEC Components

No Unlisted CEC components are used in this report.

6.0 Critical Features

Definitions for Recognized Component, Listed Component, and Unlisted Component are provided.

Critical Features/Components: Essential parts, materials, subassemblies, systems, software, or accessories impacting product conformance.

Construction Details: General requirements include:

7.0 Illustrations

Illustration 1 - Marking: Depicts the product markings including the Sonoff logo, model (IW100TPB), input/output ratings, Wi-Fi standards, FCC ID, and certifications (ETL, US, C, UL Std.498, CSA Std. C22.2 No 42), with specific size requirements for logos and text.

Illustration 2: Construction drawing of the base for model IW100TPB, showing dimensions and material specifications (PC940, V-0 flame retardant).

Illustration 3: Construction drawing of the enclosure for model IW100TPB, detailing dimensions and material specifications (PC940, V-0 flame retardant).

Illustration 4: Construction drawing of the cover plate for model KX-XP-US-005, showing dimensions and material specifications (PC940, V-0 flame retardant).

Illustration 5: Construction drawing of the L/N contact for model IW100TPB, detailing dimensions and material (phosphor copper).

Illustration 6: Construction drawing of the Grounding contact for model IW100TPB, detailing dimensions and material (phosphor copper).

Illustration 7: Construction drawing of the terminal for model IW100TPB, showing dimensions, mounting details (M3.5), and material (brass).

Illustration 8: Circuit diagram of model IW100TPB, illustrating the electrical schematic with components like transformers, capacitors, resistors, and ICs.

Illustration 9: Main circuit PCB LAYOUT of model IW100TPB, showing the placement of components on the printed circuit board.

Illustration 10: Specification of transformer XCL-EE10-5V0.5A-CR1511-2.7MH, including external dimensions, schematic, winding construction, and winding details (wire type, turns, insulation).

Illustration 11: Specification of transformer EE10-2.7mH, including external dimensions, schematic, winding order, winding construction, and remarks.

8.0 Test Summary

The following tables summarize tests performed against relevant standards.

Tests Performed (UL 498 & CSA C22.2#42)

Test Description UL 498:2017 Clause CSA Clause
Configuration Check75
Dielectric Withstand Test658.21
Mold Stress Relief Test63--
Dielectric Withstand Test(repeated)658.21
Insulation Resistnce Test678.5
Retention of Plugs Test1118.7
Overload Test1128.8
Temperature Test1138.9
Retention of Plugs Test (Repeated)1148.10
Resistance to Arcing Test1158.17
Temperature Test (Terminal)118--
Fault Current Test122--
Terminal Strength Test123--
Assembly Security Test1248.20
Grounding Contact Test1258.16.1
Pressure-Wire Terminals (General)126--
Strength of Insulating Base Test128--
Terminal screw tightening torque--8.23

Tests Performed (UL 60730-1 & CSA E60730-1)

Test Description UL 60730-1:2016 Clause CSA E60730-1:2015 Clause
Inaccessibility of live parts8.1.98.1.9
Low resistance between earth connections9.3.19.3.1
Protection against humid conditions12.212.2
Measurements of leakage current12.312.3
Insulation resistance and dielectric strength1313
Heating1414
Environmental stress16.216.2
Impact resistance18.218.2
Tumbling18.618.6
Threaded parts and connections1919
Creepage distance, clearances and distance through solid insulation2020
Abnormal operationH.27H.27

Tests Performed (UL 514D)

Test Description UL 514D Clause
Dielectric Voltage-Withstand7.4
Flame penetration for cover plates7.5
Flammability7.6
Aging7.7
Mechanical Strength7.8
Mold Stress Relief7.9
Deformation Resistance7.10

Tests Performed (EMC)

Test Description UL 60730-1:2016 Clause CSA E60730-1:2015 Clause
Conducted EmissionH.23.1.2H.23.1.2
Radiated EmissionH.23.1.2H.23.1.2
Surge ImmunityH.26.8H.26.8
Electrical Fast Transient/Burst ImmunityH.26.9H.26.9

9.0 Correlation Page For Multiple Listings

Shenzhen Sonoff Technologies Co., Ltd. is listed as the basic listee for products identical to those in this report, authorized under the Intertek Multiple Listing Program.

10.0 General Information

Applicant and Manufacturer agree to produce, test, and label ETL Listed products per this report. Authorization is required for alternate parts. Components used must be itemized in this report. The ETL Listing mark usage is controlled by Intertek and must include country identifiers, listing status, control number, and product descriptor.

Manufacturing and Production Tests: Shall be performed as required.

Follow-Up Service: Periodic unannounced audits of manufacturing facilities will be conducted by Intertek to ensure conformance to report descriptions, ETL mark usage, manufacturing changes, and test performance. Non-conformance requires corrective action, removal of the ETL Mark, or contact with the evaluation center.

10.1 Evaluation of Unlisted Components

Unlisted components may require annual testing/evaluation. Instructions are provided for shipping samples to the ETL Component Evaluation Center for re-evaluation.

11.0 Manufacturing and Production Tests

The manufacturer agrees to conduct specified tests.

11.1 Dielectric Voltage Withstand Test:

Routine production line testing of assembled products. Test voltage applied between primary circuits and accessible dead-metal parts. Test equipment requirements include a transformer, voltage indicator, and breakdown indicator.

Products Requiring Dielectric Voltage Withstand Test:

ProductTest VoltageTest Time
All products covered by this Report.1000V AC or 1200V AC60 s or 1 s

11.2 Grounding Continuity Test:

Routine production-line test to determine grounding continuity between the grounding terminal and accessible dead-metal parts. Compliance verified using an ohmmeter or battery/buzzer.

Products Requiring Grounding Continuity Test:

All products covered by this Report.

12.0 Revision Summary

No revisions have been made.

PDF preview unavailable. Download the PDF instead.

SONOFF IW100 ETL Security CDR GPL Ghostscript 9.07; modified using iText 5.5.13 ©2000-2018 iText Group NV (AGPL-version)

Related Documents

Preview Sonoff IW100/IW101 Wi-Fi Smart Wall Socket and Switch User Manual
User manual for Sonoff IW100 Wi-Fi Smart Wall Socket and IW101 Wi-Fi Smart Wall Switch, covering installation, setup, features, specifications, and troubleshooting for smart home integration.
Preview SONOFF Smart Home Products Brochure | Innovative Automation Solutions
Explore the comprehensive SONOFF product brochure showcasing a wide array of smart home devices, including Wi-Fi and Zigbee switches, plugs, lighting, sensors, and cameras. SONOFF offers quality, innovation, and simple automation for a smarter lifestyle.
Preview SONOFF iPlug Wi-Fi Smart Plug Quick Start Guide
Concise guide for setting up the SONOFF iPlug Wi-Fi Smart Plug, covering app download, device pairing, and compliance information.
Preview SONOFF POWR3 Quick Start Guide - Wi-Fi Smart Switch
Get started with your SONOFF POWR3 Wi-Fi Smart Switch. This guide covers installation, eWeLink app setup, energy monitoring features, and safety precautions for this smart home device.
Preview Sonoff S31 Wi-Fi Smart Plug EU RoHS Conformity Declaration
Declaration of EU RoHS Conformity for the Sonoff S31 Wi-Fi Smart Plug with Power Monitoring, confirming compliance with EU Directive 2011/65/EU.
Preview SONOFF BASICR2/RFR2 Wi-Fi Smart Switch User Manual
Comprehensive user manual for the SONOFF BASICR2/RFR2 Wi-Fi Smart Switch, covering installation, wiring, app setup, specifications, troubleshooting, and FCC compliance.
Preview SONOFF iPlug S40TPB Lite Wi-Fi Smart Plug User Manual
User manual for the SONOFF iPlug S40TPB Lite Wi-Fi Smart Plug, detailing setup, features, specifications, and troubleshooting for smart home control.
Preview SONOFF BASICR3/BASICRFR3 Wi-Fi Smart Switch User Manual
User manual for SONOFF BASICR3 and BASICRFR3 Wi-Fi Smart Switches. Covers installation, setup via eWeLink app, features like remote control and scheduling, RF pairing, and troubleshooting for smart home automation.