Introduction
Important: Please carefully read this manual before operation and retain it for future reference.
Front Handle and Door Lock Installation Diagram
Front Handle Components:
- Single Row Touch Buttons
- Double Row Touch Buttons
- Fingerprint Sensor ?️
- Card swiping area ?
- Digital keypad ?
- Type-C 5V Emergency charging port ?
Installation Diagram Components:
- Square rod
- M3*6 Cross countersunk screw
- M4-M5 studs
- 4 LR03AAA batteries ?
- Mechanical key ?
- Front handle
- Back handle cover
- Back handle
- Lock cylinder
- M4*21 Screw
- Door gusset plate
- Latch Box
- M4*40 Cross countersunk screw
Installation Steps Overview:
- Use two screws to fix the latch box and door gusset plate on the door frame.
- Use two self-tapping screws to firmly fix the 6070 lock on the door.
- After the wire passes through the square rod hole, pass the square rod through the square hole of the lock.
Buttons:
- ? "Reset" button (hold for 5 seconds)
- ? "Always-open" button (hold for 3 seconds)
Measuring the Door
Ensure the following dimensions for your door:
- Thickness: 30 - 50 mm
- Door opening hole diameter: 54 mm (2.12 inches)
- Distance from lock body to door bolt back: 60/70 mm
Tips:
- Applicable door thickness is 30~50mm. If the door thickness exceeds this range, please contact the manufacturer for more information.
- For doors 30-40mm thick, use 28mm studs.
- For doors 41-50mm thick, use 40mm studs.
Accessories List
Open the product package and check whether the following accessories are included: ✔️
- Front Handle x1
- Back Handle x1
- Lock cylinder x1
- Needle x1
- Studs x2
- M4*40 Screw x2
- 60/70 Latch Box x1
- Mechanical Key x1 ?
- 105 Square rod x1
- M4*21 Screw x4
- 60/70 Door gusset plate x1
- IC Card x2 ?
Installation Steps
Please install the door lock according to the following steps:
- Adjust Backset: Adjust the backset (60/70 mm) of the lock body according to requirements. Hold the square hole on the lock firmly. The shifting part must be pushed to the edge of the lock, and the front and back square holes must be in a horizontal state.
- Fix Lock Cylinder: Fix the lock cylinder with two screws.
Product Features and Advantages
- Unlock methods: Fingerprint ?️, Password ?, Card ?, Key ?.
- Multiple volume modes available for user-friendly operation.
- Function to prevent others from seeing the password (virtual anti-peeping).
- Automatically detects power level and provides early warning ?.
- All components are from internationally renowned brands with stable and reliable quality.
- Door lock modules are waterproof, moisture-proof, and mildew-proof.
- Door lock modules have undergone high and low temperature, vibration, aging, and other tests to adapt to harsh environments.
User Registration Logic:
- When no user is registered, any fingerprint or the initial password "123456" can unlock the smart lock.
- When a fingerprint or password is registered, unauthorized attempts will no longer work.
- When no administrator is set, any fingerprint or the initial password "123456" can access add mode.
- When an administrator is registered, their verification is required to enter add mode and add new users.
Detailed Operation of Lock End
1. Add User
Procedure: Enter "10#", Verify administrator, Enter unlock information, Add user.
- When verifying the administrator, if no administrator is registered, any fingerprint or the initial password "123456" can be used to enter and add the administrator/user.
- The first three users are administrators; the fourth or more users are regular users.
- The valid length for a numeric password is 6 digits. Registration will fail if the password exceeds this length.
- Fingerprints need to be entered 5 times; passwords 2 times consecutively; cards entered once. A successful input is indicated by a green light.
- After successful registration, the system will automatically enter sleep mode.
- The maximum number of users is 200.
2. Volume Setting
Procedure: Enter "21#", Verify administrator, Select volume.
Volume Options: 1 Low, 2 Medium, 3 High, 0 Quiet.
- If no administrator is registered, enter the initial password or any fingerprint to set the volume after entering "21#".
- In the volume setting interface, only keys 1, 2, and 3 are valid for selection. Pressing other keys will be invalid, and the volume setting mode will pop up.
- After other numbers are deleted by the administrator, the system will automatically replace their numbers when they are entered again.
3. System Initialization
Procedure: Enter "888#", Verify administrator, Initialization.
- After entering "888#" and verifying the administrator, the system will be initialized directly.
- After initialization, anyone can unlock the door without a password. After setting up an administrator, their verification is required to unlock the door.
4. Always Open Mode Selection
Procedure: Enter "28#", Verify administrator, Always open mode on/off.
- If no administrator is registered, the always open mode will be turned on/off directly after entering "28#".
- In the normally open mode, this mode will be automatically closed after the password is entered.
5. Switch/Button Operations
Buttons: S1 (Reset switch), S2 (Normally open button).
- S1 Short Press: Add administrator/user function. Requires administrator verification if one is already registered.
- S1 Long Press: Force the system into initialization mode without administrator verification.
- S2 Short Press: Quickly turn on/off the normally open mode. Requires administrator verification to turn on.
- Press Duration: Long press is considered longer than 5 seconds; any time shorter than 5 seconds is a short press.
6. Enter IC Card
Procedure: Enter "10#", Verify Administrator, Enter IC card.
- First, register as an administrator and set up according to "1. Add User Operation".
- After entering "10#", the administrator needs to verify it; ordinary users cannot perform this operation.
- After successful verification by the administrator, place the IC card in the "swipe card area" for sensing. A "ding" sound ? indicates successful entry.
- Perform operations "2" and "3" again to enter the second IC card.
APP Download (Optional)
Instructions:
- Please download the "tuya" app from the App store/Play store.
- Alternatively, scan the QR code provided in the original document to download the software.
- Ensure the device is powered on normally and operate without registering an administrator.
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.