Solis Solarator S6-EH3P Series Hybrid Inverters
Experience uninterrupted power with Ginlong inverters.
Key Advantages
- Flexible PV access, supporting DC and AC coupling for system upgrades and expansion.
- Battery retention for reliable backup power in various scenarios.
- Intelligent load management for extended critical load runtime.
- Smart three-in-one interface for flexible integration of multiple energy sources like diesel generators, solar, and wind power.
- Seamless grid-to-off-grid transition in under 10ms.
- Supports up to 10 units in parallel, with Ginlong distribution boxes recommended for more than 6 units.
Unique Advantages
- Inverter rated power is 2x the available PV power, maximizing solar energy utilization.
- Max 21A string input current, perfectly matching high-power PV modules.
- Compatible with 100-314Ah battery modules.
- Supports fast charging with a maximum charging current of 200A.
- Robust off-grid load capacity, supporting 160% overload.
- Supports a wide range of generator input power (25-125kVA).
- Dual independent battery interfaces for flexible system configurations.
- Features a 7-inch industrial-grade LCD screen from ZETTLER.
Technical Specifications
Specification | S6-EH3P(75-125)K10-NV-YD-H | 75K | 80K | 100K | 125K |
---|---|---|---|---|---|
DC Input (PV Side) | |||||
Recommended Max PV Module Power | 150 kW | 160 kW | 200 kW | 240 kW | |
Max Usable PV Input Power | 150 kW | 160 kW | 200 kW | 240 kW | |
Max Input Voltage | 1000 V | ||||
Rated Input Voltage | 600 V | ||||
Startup Voltage | 180 V | ||||
MPPT Voltage Range | 150-950 V | ||||
Max Input Current | 114 A / 108.3 A | ||||
Max Input Short Circuit Current | 10/20 | ||||
MPPT Number / Max PV Strings per MPPT | 10/20 | ||||
Battery | |||||
Battery Type | Lithium Battery | ||||
Battery Voltage Range | 300-950 V | ||||
Max Charge/Discharge Current | 200 A / 100 A + 100 A | ||||
Battery Port Number | 2 | ||||
Max Charge/Discharge Current per Battery Port | 100 A | ||||
AC Output (Grid Side) | |||||
Rated Output Power | 75 kW | 80 kW | 100 kW | 125 kW | |
Max Output Apparent Power | 75 kVA | 80 kVA | 100 kVA | 125 kVA | |
Rated Grid Voltage | 3/N/PE, 220 V / 380 V, 230 V / 400 V | ||||
Rated Grid Frequency | 50 Hz / 60 Hz | ||||
Rated Grid Output Current | 121.6 A / 115.5 A | 152 A / 144.3 A | 180.4 A / 189.9 A | 250 A | |
Power Factor | 0.99 (0.8 leading... 0.8 lagging) | ||||
Total Current Harmonic Distortion | < 3% | ||||
AC Input (Grid Side) | |||||
Max Input Current | 250 A | ||||
AC Output (Off-Grid Side) | |||||
Rated Output Power | 75 kW | 80 kW | 100 kW | 125 kW | |
Max Output Apparent Power | 100s continuous output 1.2x rated power | 10s continuous output 1.4x rated power | 200ms continuous output 1.6x rated power | 10mins continuous output 1.2x rated power; 100s continuous output 1.4x rated power; 10s continuous output 1.6x rated power; 200ms continuous output 2x rated power | |
Grid-to-Off-Grid Switching Time | < 10 ms | ||||
Rated Output Voltage | 3/N/PE, 220 V / 380 V, 230 V / 400 V | ||||
Rated Frequency | 50 Hz / 60 Hz | ||||
Total Voltage Harmonic Distortion | < 2% | ||||
Efficiency | |||||
Max Efficiency | 97.6% | 97.2% | 97.0% | 97.0% | |
European Efficiency | 97.6% | 97.2% | 97.0% | 97.0% | |
Max Battery Charge/Discharge Efficiency | 97.0% | ||||
Protection | |||||
Islanding Protection | Yes | ||||
AC Output Overcurrent Protection | Yes | ||||
AC Short Circuit Protection | Yes | ||||
Integrated DC Switch | Yes | ||||
DC Reverse Polarity Protection | Yes | ||||
Surge Protection | Yes | ||||
DC Arc Fault Protection | Optional | ||||
Protection Rating / Overvoltage Category | Level I / Level II | ||||
Basic Parameters | |||||
Max Allowable Phase Imbalance (Grid & Off-Grid) | 100% | ||||
Max Power per Phase (Grid & Off-Grid) | 25.00 kW | 26.66 kW | 33.33 kW | 41.66 kW | |
Dimensions (W×H×D) | 1174 × 814 × 400 mm | ||||
Weight | 170 kg | ||||
Topology | Transformerless | ||||
Operating Ambient Temperature | -25~+60° C | ||||
Ingress Protection Rating | IP66 | ||||
Cooling Method | Smart Fan Cooling | ||||
Max Operating Altitude | 3000 m | ||||
Grid Connection Standards | G99, VDE-AR-N 4105/VDE V 0124, EN 50549-1&2/EN 50549-10, VDE 0126/UTE C 15/VFR:2019, NTS 631/RD 1699/RD 244/ UNE 206006/UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA, PORTARIA Nº 140, DE 21 DE MARÇO DE 2022; Brazil (75K: ORDINANCE (PORTARIA) NO.140, ORDINANCE NO. 515; 100K/125K: NBR 16149, NBR 16150, IEC 62116) | ||||
Safety / EMC Standards | IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4, EN 55011 | ||||
Features | |||||
PV Port | MC4 Fast Connector | ||||
Battery Port | Terminal Block | ||||
AC Port | Terminal Block | ||||
Display | 7" LCD Display, Bluetooth + APP | ||||
Communication | CAN/RS485-115200 / Ethernet / Wi-Fi (Optional) / Cellular (Optional) / LAN (Optional) |