FSP PU60 Series 37.5-64 Watt ITE Power Supplies
Description
The PU60 series comprises compact, open PCB constructed, AC-DC switching power supplies. These units are capable of delivering 37.5 to 64 watts of continuous output power under convection cooling. They operate with a wide-range input voltage of 90-264 VAC, eliminating the need for manual voltage selection. The series is well-suited for applications in data networking, computer systems, telecommunications, audio/video equipment, and industrial environments.
Features
- Compact size: 2" x 4" x 1.18"
- Available in single, dual, and triple output configurations.
- Wide-range input: 90-264 VAC.
- Meets Level B emissions standards.
- RoHS compliant.
Input Specifications
Parameter | Value |
---|---|
Input voltage | 90-264 VAC |
Input frequency | 47-63 Hz |
Input current | 1.3 A (rms) for 100 VAC; 0.7 A (rms) for 240 VAC |
Earth leakage current | 150 μA max. @ 264 VAC, 63 Hz |
Output Specifications
Output voltage/current: See rating chart.
Maximum output power: See rating chart.
Ripple and noise: 100 mV peak to peak for 3.3 V & 5.0 V models; 1% peak to peak for other models.
Overvoltage protection: Provided on output #1 only; set at 112-132% of its nominal output voltage.
Overcurrent protection: All outputs are protected against short circuit conditions.
Temperature coefficient: All outputs ±0.04% /°C maximum.
Transient response: Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 μs after a 25% step load change.
Environmental Specifications
Parameter | Value |
---|---|
Operating temperature | -10°C to +70°C |
Storage temperature | -40°C to +85°C |
Relative humidity | 5% to 95% non-condensing |
Temperature derating | Derate from 100% at +50°C linearly to 50% at +70°C |
Safety Standard Approvals
- UL 62368-1, CSA C22.2 No. 62368-1
- TÜV EN 62368-1
General Specifications
Parameter | Value |
---|---|
Switching frequency | 62 K ±5 KHz |
Efficiency | 80-88% typical (except PU60-31-3A and PU60-31-5A at 75% typical) |
Hold-up time | 12 ms minimum at 110 VAC |
Line regulation | ±0.5% maximum at full load |
Inrush current | 30 A @ 115 VAC, or 60 A @ 230 VAC, at 25°C cold start |
Withstand voltage | 4242 VDC from input to output, 2500 VDC from input to ground, 707 VDC from output to ground |
MTBF | 400,000 hours at full load at 25°C ambient, calculated per MIL-HDBK-217F |
EMC Performance
- EN55032: Class B conducted, class B radiated
- EN61000-3-2: Harmonic distortion, class A
- EN61000-3-3: Line flicker
- EN55024:
- EN61000-4-2: ESD, ±8 KV air and ±4 KV contact
- EN61000-4-3: Radiated immunity, 3 V/m
- EN61000-4-4: Fast transient/burst, ±1 KV
- EN61000-4-5: Surge, ±1 KV diff., ±2 KV com
- EN61000-4-6: Conducted immunity, 3 Vrms
- EN61000-4-8: Magnetic field immunity, 1A/m
- EN61000-4-11: Voltage dip immunity, 30% reduction for 500 ms and >95% reduction for 10 ms
Output Voltage/Current Rating Chart
Model | Output #1 | Output #2 | Output #3 | Max. Output Power | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
V1 | Min. Current at convection | Max. Current at 5 CFM | V2 | Min. Current | Max. Current | V3 | Min. Current | Max. Current | ||||||
PU60-10A | 5V | 0A | 11.0 A | (N/A) | (N/A) | (N/A) | (N/A) | (N/A) | (N/A) | 55 W | ||||
PU60-12A | 12V | 0A | 5.0 A | (N/A) | (N/A) | (N/A) | (N/A) | (N/A) | (N/A) | 60 W | ||||
PU60-13A | 15V | 0A | 4.3 A | (N/A) | (N/A) | (N/A) | (N/A) | (N/A) | (N/A) | 64 W | ||||
PU60-14A | 24V | 0A | 2.7 A | (N/A) | (N/A) | (N/A) | (N/A) | (N/A) | (N/A) | 64 W | ||||
PU60-18A | 48V | 0A | 1.35 A | (N/A) | (N/A) | (N/A) | (N/A) | (N/A) | (N/A) | 64 W | ||||
PU60-23A | +5V | 0.5 A | 6.0 A | 8 A | ±3% | +12V | 0.1 A | 3.0 A | ±5% | (N/A) | 55 W | |||
PU60-25A | +5V | 0.5 A | 6.0 A | 8 A | ±3% | +24V | 0.1 A | 1.5 A | ±5% | (N/A) | 55 W | |||
PU60-31A | +5V | 0.5 A | 6.0 A | 8 A | ±3% | +12V | 0.1 A | 3.0 A | ±5% | -12V | 0A | 0.5 A | ±4% | 55 W |
PU60-31-3A | +3.3V | 0.8 A | 6.0 A | 8 A | ±3% | +5.2V | 0.1 A | 3.0 A | ±5% | +12V | 0A | 0.5 A | ±4% | 37.5 W |
PU60-31-5A | +5V | 0.5 A | 6.0 A | 8 A | ±3% | +3.3V | 0A | 1.5 A | ±5% | +12V | 0A | 0.5 A | ±4% | 37.5 W/47.5 W |
PU60-32A | +5V | 0.5 A | 6.0 A | 8 A | ±3% | +15V | 0.1 A | 2.4 A | ±5% | -15V | 0A | 0.5 A | ±4% | 55 W |
PU60-39A | +5V | 0.5 A | 6.0 A | 8 A | ±3% | +24V | 0.1 A | 1.5 A | ±5% | -12V | 0A | 0.5 A | ±4% | 55 W |
Notes:
- Safety approvals are for PCB form only. To order units with a cover fitted, change the suffix "A" to "C".
- Maximum current for output #1 on multi-output models can be 8 A when using 5 CFM forced air provided by the user.
- 47.5 W rating is applicable with 5 CFM forced air provided by the user.
- Output voltages on multi-output models may deviate from stated tolerances if an output load current is outside the stated limits. All models can be operated without load and will not be damaged.
- Ripple and noise is the maximum peak-to-peak voltage measured at the output within a 20 MHz bandwidth, at the rated line voltage and output load ranges. A 10 µF tantalum capacitor in parallel with a 0.1 µF ceramic capacitor is placed across the output.
Mechanical Specifications
The power supply unit has a compact open PCB construction. Key dimensions are approximately 2 inches (width) x 4 inches (depth) x 1.18 inches (height). Mounting holes are provided, with a diameter of 0.157 inches (4.00 mm) for four mounting points. A ground tab is also present, measuring 0.25 inches (6.35 mm) by 0.032 inches (0.8 mm). Connector CN1 is a Molex header (part number 09-65-2038 or equivalent) mating with Molex housing 09-50-1031 or equivalent. Connector CN2 is a Molex header (part number 09-65-2068 or equivalent) mating with Molex housing 09-50-1061 or equivalent. To comply with Level B emissions, two mounting holes marked with an asterisk (*) should be connected to the chassis using metallic standoffs. The approximate weight of the unit is 205 grams (0.45 lbs).
Output Power Derating Curve
The output power derating curve illustrates the relationship between ambient temperature and maximum output power. The graph shows Output Power (%) on the vertical axis and Ambient Temperature (°C) on the horizontal axis. The curve starts at 100% output power at 50°C and decreases linearly to 50% output power at 70°C. The operating temperature range shown is from -10°C to 70°C.
Pin Chart
MODEL | PIN 1 | PIN 2 | PIN 3 | PIN 4 | PIN 5 | PIN 6 |
---|---|---|---|---|---|---|
PU60-10A, PU60-14A | +V1 | +V1 | V1 Return | V1 Return | N.C. | N.C. |
PU60-12A, PU60-18A | +V1 | +V1 | V1 Return | V1 Return | N.C. | N.C. |
PU60-13A | +V1 | +V1 | V1 Return | V1 Return | N.C. | N.C. |
PU60-23A, PU60-25A | V1 | V1 | Common Return | N.C. | V2 | |
PU60-31A, PU60-32A, PU60-39A | V1 | V1 | Common Return | V3 | V2 | |
PU60-31-3A, PU60-31-5A | V1 | V1 | Common Return | V3 | V2 |