Panasonic Installation Instructions: Ventilating Fan

Model Numbers: FV-0511VK2, FV-1115VK2, FV-0511VKS2

Representative Models

Illustrations show the FV-0511VK2 and FV-0511VKS2, and the FV-1115VK2.

Contents

Read and Save These Instructions

Thank you for purchasing this Panasonic product. Please read these instructions carefully before attempting to install, operate, or service the Panasonic product. Please carefully read the "GENERAL SAFETY INFORMATION". Failure to comply with instructions could result in personal injury or property damage. Please explain to users how to operate and maintain the product after installation, and this booklet should be presented to users. Please retain this booklet for future reference.

General Safety Information

To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always observe the following safety precautions.

Explanation of Symbol Word Panels

The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage caused when the denotation is disregarded and improper use is performed:

Explanation of Symbols

The following symbols are used to classify and describe the type of instructions to be observed:

WARNING

CAUTION

NOTICE

Diagram showing improper duct configurations: excessive bending, successive bending, squeezed duct. It also shows the correct way to bend close to the duct adapter.

When one switch is connected with two or more products in parallel, the unit may not function. Therefore, parallel connection should not be allowed.

Please Read Prior to Installing This Fan

Spot and Continuous Ventilation: These fans are designed to run continuously, ensuring a healthy environment at low CFM levels 24 hours a day. By utilizing the optional CustomVent Multi-Speed module, the fans are built to run continuously at a pre-set lower level (FV-0511VKS2 and FV-0511VK2: 0, 30, 40, 50, 60, 70, 80, 90, 100 CFM; FV-1115VK2: 0, 50, 60, 70, 80, 90, 100, 110, 120 CFM). The setting is dependent on the size of the house and the individual wishes of the homeowner. It is crucial that the installer pre-set the lower setting during the installation. Please refer to the chart below and the switch indication on page 6.

CustomVent Multi-Speed Module (Lower Setting) ASHRAE 62.2-2016

(sq.feet) Two Bedrooms Three Bedrooms Four Bedrooms Five Bedrooms
< 500 38 45 53 60
501-1000 53 60 68 75
1001-1500 68 75 83 90
1501-2000 83 90 98 105
2001-2500 98 105 113 120
2501-3000 113 120 128 135
3001-3500 128 135 143 150
3501-4000 143 150 158 165
4001-4500 158 165 173 180
4501-5000 173 180 188 195

These fans are also built to take care of the homeowner's spot ventilation needs when the room is occupied. The basic fan models allow a choice of three speeds. When fans are equipped with the optional Multi-Speed module, these models kick up to a maximum level of 150 CFM for the FV-1115VK2 and 110 CFM for the FV-0511VKS2 and FV-0511VK2 either when the switch is turned on or activated by the optional Condensation Sensor module or the optional Motion Sensor module.

A High/Low Delay Timer, located inside the fan unit, is utilized to return the fan back to the pre-set Continuous ventilation mode. The installer needs to consult with the homeowner for the desired setting on the timer (0 - 60 minutes) and make the adjustments during the installation.

Description

These products are listed by UL under UL file No. E78414. These products use a sirocco fan driven by a DC motor powered by an integral transformer. The motor is designed to have long operating life, high dynamic response, higher speed ranges with saving energy. The grille covering the fan body is a spring-loaded, quick remove type. A damper for preventing air counter flow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level.

Unpacking

Unpack and carefully remove the unit from packing. Refer to the Supplied Accessories list to verify that all parts are present.

Supplied Accessories

Part name Appearance Quantity Part name Appearance Quantity
Grille

[Grille illustration]

1 Warranty sheet

[Warranty sheet illustration]

1
Flex-Z Fast™ bracket (with 4 tapping screws ST4.2X20)

[Bracket illustration]

1 Installation instructions

[Instructions booklet illustration]

1
Self-drilling screw

[Screw illustration]

4

Dimensions

Diagrams showing the dimensions for FV-0511VKS2, FV-0511VK2, and FV-1115VK2 models in inches and millimeters.

No. Part name No. Part name
1 Blade 7 Connector cover
2 Grille 8 Base PCB box
3 Junction box 9 Pick-A-Flow switch
4 Adaptor 10 Fan body
5 Main PCB box 11 Damper
6 Multi-Speed module (FV-0511VKS2 only, other models not included) 12 Flex-Z Fast™ bracket
Motion sensor location (FV-MSVK1 not included) 13

Wiring Diagram

Diagram illustrating the wiring connections for the fan body, junction box, and power switch, including connections for DC motor, Multi-Speed module, Plug 'N Play module slots, and earth ground. It specifies connections for Live (Fan), Neutral, and indicates AC 120V 60Hz power supply. It also provides instructions for using the signal switch for manual control of High/Low CFM modes and warns against connecting red signal wires to a live power supply.

Feature

Optimum Ventilation Performance

Duct length, elbows, and other factors increase static pressure, which can hinder the performance of most ventilation fans. This fan utilizes Smart Flow microchip technology that monitors the static pressure in the system and speeds up or slows down the RPM of the fan depending upon the amount of resistance within the ducts. This feature allows the fan to perform as rated and avoid potential installation issues.

Outstanding Energy Savings

The WhisperGreen Select Line of fans are built using DC motor technology. The DC motor is 30% - 70% more energy efficient than the minimum ENERGY STAR requirements.

Pick-A-Flow Feature

All the WhisperGreen Select base models of fans come with Pick-A-Flow speed options. The Pick-A-Flow switch on the face of all WhisperGreen Select fans allows the option to choose 50 – 80 – 110 CFM for the FV-0511VK2, FV-0511VKS2 or 110 – 130 – 150 CFM for the FV-1115VK2. These fans can run continuously or intermittently, depending upon the needs of the owner.

Air volume type (CFM)

Model Factory setting
FV-0511VKS2 50 80 110 80 CFM
FV-0511VK2 50 80 110 80 CFM
FV-1115VK2 110 130 150 130 CFM

Indication (Plug 'N Play Function Devices)

Note: There is ONLY ONE Plug 'N Play slot to insert the Multi-Speed module within the base model fan. There are TWO interchangeable Plug 'N Play slots to insert the Condensation Sensor module, Motion Sensor module within the base model fan.

PLUG 'N PLAY Modular Component Accessories (Sold Separately, Not Included With Base Model Fan)

FV-VS15VK1 Multi-Speed module allows the fan to run continuously at lower speeds to maintain ventilation standards to meet Indoor Air Quality and then boost up to high speed to meet intermittent needs for ‘Spot’ or 'Point Source' exhaust needs. The FV-VS15VK1 Modular Component will operate for both the FV-0511VK2 and the FV-1115VK2 matching the appropriate Multi-Speed setting shown below. The FV-0511VKS2 comes with the FV-VS15VK1 Multi-Speed module. It is not necessary to purchase this component.

Note the options on the face of the FV-VS15VK1 Multi-Speed module to choose appropriate levels of airflow (CFM) and time delay before returning back to low speed (TIME). Choosing the Pick-A-Flow setting automatically adjusts the Multi-Speed setting accordingly. As an example, if the Pick-A-Flow Multi-speed setting is 80 CFM, the Multi-Speed settings adjust automatically to be 0, 30, 40, 50, 60 or 70 CFM at the lower speeds. The fan will ‘boost’ to the 80 CFM speed as the high speed setting. Selecting a particular TIME option will cause the fan to run for the selected amount of time before returning to the lower speed setting chosen on the CFM dial.

Pick-A-Flow (CFM) vs. Multi-Speed Air Volume (CFM)

Pick-A-Flow (CFM) Multi-Speed Air volume (CFM) TIME (min)
0 30 40 50 60 70 80 90 100
FV-0511VKS2, FV-0511VK2 (plug-in FV-VS15VK1) 0 30 40 40 40 40 40 40 40 0.5, 5, 10, 20, 30, 45, 60
FV-1115VK2 (plug-in FV-VS15VK1) 0 50 60 70 80 90 100 110 110 0.5, 5, 10, 20, 30, 45, 60

Delay Time (min)

0 0.5 5 10 20 30 45 60
Factory setting: 20 minutes.
Delay Time position "0" : Manual wall switch control is 0 minute; without manual wall switch control is 0.5 minute.

FV-CSVK1 Condensation Sensor module turns the base fan on or boosts to higher speed when humidity is detected when used in combination with the FV-VS15VK1. The Condensation Sensor works based on calculations from the Psychrometric Chart, or combination of Relative Humidity (RH) and Temperature. This allows the fan to anticipate the formation of condensation and automatically turn on when needed to expel humid air. The Condensation Sensor is pre-set to run for 20 minutes; it will then check the RH and Temperature to detect if the fan needs to run for another 20 minutes cycle.

Indication (Plug 'N Play Function Devices) Continued

Humidity selector range from around 30% to 80%. Factory setting is around 50%.

Timer [min] 0.5 1 2 3 5 10 20 30 60
Factory setting: 20 minutes.
Position " " : For factory use
  1. The product will run when environment humidity rises rapidly but not reach to the humidity setting, and stop after delay preset time.
  2. Humidity setting selector is stepless change between 30 %RH ~ 80 %RH.
  3. The humidity detected by sensor may differ from the value on your hygrometer.
  4. The product may turn on and off cause by the unstable environment humidity, you can improve it by adjusting the Humidity setting selector.

PLUG 'N PLAY Modular Component Accessories (Sold Separately, Not Included With Base Model Fan)

FV-MSVK1 Motion Sensor module turns the base fan on or boosts to higher speed when motion is detected when using in combination with the FV-VS15VK1. The Motion Sensor is pre-set to run for 20 minutes; it will then re-check for movement; if detected the fan will run for another 20 minutes cycle. The Motion Sensor detects within the range shown below.

Diagram showing the detection range and field of view of the Motion Sensor.

PLUG 'N PLAY Modular Components used in Combinations

Diagrams illustrating combinations of modules and their functions:

Motion Fan operation Time delay operation
FV-CSVK1 only Fan active 20 minutes time delay
FV-MSVK1 only Human active ON/OFF
FV-CSVK1 + FV-VS15VK1 When motion or excess humidity is detected, fan runs at high speed until the delay time has passed. Fan ON/OFF Depend on FV-VS15VK1 Time delay setting
FV-MSVK1 + FV-VS15VK1 Hi/Low speed

Installation (Plug 'N Play Function Devices)

You can purchase the specified Plug 'N Play devices that are explained on pages 6-7 and install them in positions 1, 2, and 3. Position 1 can only be used with the Multi-Speed module (model FV-0511VKS2 already has this control installed), positions 2 and 3 can be used for any of the other optional control modules.

  1. Remove the connector cover from position 1, 2, or 3.
  2. Plug in the specified devices to the Base PCB box and fix to the slot, till you hear the sound of it installed in place.

Diagram showing how to remove and install the connector clasp.

Installation (New Construction)

The fan position between joists from 16" to 24" on center can be adjusted flexibly.

CAUTION

Please wear gloves during the installation work.

  1. Disconnect plug connector from receptacle and remove adaptor from fan body by removing the machine screw (M4X8) before installation. (Fig.1)
  2. IMPORTANT: Remove the tape from the damper and adaptor before installation.
  3. Bend down 4 tabs for positioning, install the Flex-Z Fast™ bracket to joists by drilling 2 tapping screws which have been fixed on it. (Fig.2)
  4. Adjust the length of the Flex-Z Fast™ bracket as the spacing between joists, and install to joists by drilling the other 2 tapping screws which have been fixed on it. (Fig.3)
  5. Remove junction box cover and secure conduit or stress relief to the junction box knock-out hole. (Fig.4)
  6. Install a circular duct and secure it with clamps, or ties and seal it with mastic or approved foil tape. A 4 or 6 inch circular duct is needed to connect to the relevant part of the adaptor. (Fig.4)
  7. Install the adaptor to the Flex-Z Fast™ bracket by using 2 self-drilling screws. (Fig.4)

Diagrams illustrating steps 1-4 of the new construction installation.

Installation (New Construction) Continued

  1. Refer to wiring diagram on page 5. Follow all the local electrical safety codes as well as the National Electrical Code (NEC). Using UL approved wire nuts, connect house power wires to ventilating fan wires. (Fig.5)
  2. CAUTION: Mount junction box cover carefully so that lead wires are not pinched.
  3. Insert fan body and slide into adaptor assembly with some strength, until the flange overlaps the Flex-Z Fast™ bracket. Secure the fan body to Flex-Z Fast™ bracket by using 2 self-drilling screws, plug connector to receptacle and secure the fan body to adaptor by using machine screw (M4X8). (Fig.6)
  4. CAUTION: Secure machine screw (M4X8) to the suitable hole and not touch the Flex-Z Fast™ bracket. Please fix the screw carefully to avoid screw slip teeth.
  5. Finish ceiling work. Ceiling hole should be aligned with the inside edge of the flange. (Fig.7)
  6. Adjust Pick-A-Flow switch. (Refer to indication on FEATURE)
  7. Insert the grille mounting spring on the wiring side into the slot. (Fig.8)
  8. IMPORTANT: Replace the sensor cover before the installation (only for plug-in Motion sensor module FV-MSVK1).
  9. Diagrams illustrating steps 5-9 of the new construction installation.

Installation (New Construction) Continued

  1. Insert the other mounting spring into the slot as shown and mount grille to fan body. (Fig.10)
  2. CAUTION: Mount grille carefully so that lead wire is not pinched.
  3. Attention: When the switch is at the “ON” position, wait 8 – 10 seconds for the fan to start. This is a normal working condition.

Installation (Retrofit)

WARNING

Disconnect power source before working on unit.

  1. Remove the existing fan and cut ceiling opening. Secure the Flex-Z Fast™ bracket to joists by drilling 4 tapping screws (ST4.2x20) which have been fixed on it. Existing ductwork and wiring left in place. (Fig.11)
  2. Follow the step 1, 4, 5, 7 on INSTALLATION (NEW CONSTRUCTION). (Before connecting the circular duct to the adaptor, pull down the circular duct from the ceiling)
  3. Install the adaptor to the Flex-Z Fast™ bracket by using 2 self-drilling screws. (Fig.12)
  4. Secure the fan body to the Flex-Z Fast™ bracket by using 2 self-drilling screws, plug connector to receptacle and secure the fan body to adaptor by using machine screw (M4X8). (Fig.13)
  5. CAUTION: Secure machine screw (M4X8) to the suitable hole and not touch the Flex-Z Fast™ bracket. Please fix the screw carefully to avoid screw slip teeth.
  6. Follow the step 10 to 12 on INSTALLATION (NEW CONSTRUCTION).

Diagrams illustrating steps 1-5 of the retrofit installation.

Maintenance (Cleaning)

WARNING

Disconnect power source before working on unit.

CAUTION

Routine maintenance must be done every year. Please wear gloves during the cleaning work.

  1. Remove grille by pulling down one mounting spring (Fig.14), then pull down the other. (Pull down the mounting spring that without lead wire passed side, and remove motion sensor as shown in Fig.15) (Squeeze mounting spring and pull down carefully).
  2. Clean grille. (Don't put into hot water. Use non-abrasive kitchen detergent, wipe dry with clean cloth) (Fig.16).
  3. The grille should be dry after cleaning.
  4. Remove dust and dirt from fan body using a vacuum cleaner. (Fig.17).
  5. Using a cloth dampened with kitchen detergent, remove any dirt from fan body. Wipe dry with clean cloth. (Fig.18).
  6. Reinstall grille.

Diagrams illustrating the cleaning process.

Practical Guide to Installation

Properly insulate the area around the fan to minimize building heat loss and gain. (Fig.19) Loose fill or batt insulation can be placed directly over the fan housing in the attic. Panasonic fans do not create excessive heat that is a common problem with recessed light fixtures or some competitor's fan/light combinations. Panasonic's efficient, cool-running motors do not create enough ambient heat to be subjected to these limitations.

The ducting from this fan to the outside of the building has a strong effect on the air flow, noise, and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated air flow.

Diagram illustrating proper duct installation and insulation.

Specifications

Specifications for Base Model fans

Model No. Air direction Voltage (V) Frequency (Hz) Duct diameter (inches) Air volume at 0.1"WG (CFM) Noise (sones) Speed (rpm) Power (W) Weight lb.(kg)
FV-0511VKS2 Exhaust 120 60 4 or 6 110 <0.3 920 9.9 10.1(4.5)
FV-0511VK2 80 <0.3 795 5.1
FV-1115VK2 6 50 <0.3 722 3.1
150 <0.3 684 12.9
130 <0.3 645 9.2
110 <0.3 625 6.9

HVI Certified performance based on HVI Procedures 915, 916, and 920.

Specifications for Multi Speed fans

Model No. Air direction Voltage (V) Frequency (Hz) Duct diameter (inches) Air volume at 0.1"WG (CFM) Noise (sones) Speed (rpm) Power (W) Weight lb.(kg)
FV-0511VKS2, FV-0511VK2 (Plug-in FV-VS15VK1) Exhaust 120 60 4 or 6 100 <0.3 889 7.9 10.1(4.5)
90 <0.3 839 6.5
80 <0.3 795 5.1
70 <0.3 760 4.3
60 <0.3 751 3.7
50 <0.3 722 3.1
40 <0.3 707 2.7
30 <0.3 711 2.4
0 0.5 (*)
FV-1115VK2 (Plug-in FV-VS15VK1) 6 120 <0.3 633 7.7 10.1(4.5)
110 <0.3 625 6.9
100 <0.3 615 5.5
90 <0.3 602 4.7
80 <0.3 608 4.2
70 <0.3 591 3.7
60 <0.3 608 3.3
50 <0.3 609 3.0
0 0.5 (*)

Reference performance based on HVI Procedures 915, 916, and 920. [(*) Standby wattage.]

Product Service

Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit require service or parts, call Panasonic Call Center at 1-866-292-7299 (USA) or 1-800-669-5165 (Canada).

Panasonic Corporation of North America
Two Riverfront Plaza, Newark, NJ 07102
www.panasonic.com

Panasonic Canada Inc.
5770 Ambler Drive, Mississauga, Ontario L4W 2T3
www.panasonic.ca

Panasonic Corporation 2018

Printed in Mexico

P0816-0 15VK20420

Models: Ventilating Fan, FV-0511VK2, FV-1115VK2, FV-0511VKS2

File Info : application/pdf, 12 Pages, 7.78MB

PDF preview unavailable. Download the PDF instead.

C1W9pbWD2tS

References

Corel PDF Engine Version 17.0.0.491

Related Documents

Preview Panasonic Ventilating Fan Installation Instructions - FV-0511VKSL3K and other models
Comprehensive installation guide for Panasonic WhisperGreen Select ventilating fans, including models FV-0511VKSL3K, FV-0511VKSL3, FV-0511VKL3, and FV-1115VKL3. Covers safety information, unpacking, parts, wiring diagrams, features, installation procedures for ceiling and wall mounting, retrofit installations, maintenance, and specifications.
Preview Panasonic FlexDamper PC-RD05C5 Specification Submittal Data for Combustible Assemblies
Specification submittal data for the Panasonic FlexDamper™ (model PC-RD05C5), a UL and cUL listed radiation damper designed for combustible assemblies, meeting UL 555C standards for 1-hour fire-rated wood truss assemblies. Includes product features, compatible ENERGY STAR® models, and installation information.
Preview Panasonic Ventilating Fan Installation Instructions
Installation instructions for Panasonic FV-05-11VKS1, FV-05-11VK1, and FV-11-15VK1 ventilating fans. Includes safety information, features, installation steps for new construction and retrofit, maintenance, specifications, and product service.
Preview Panasonic Ventilating Fan Installation Instructions
Comprehensive installation instructions for Panasonic WhisperGreen ventilating fans, covering models FV-13VKM3, FV-08VKM3, FV-13VKS3, FV-08VKS3, FV-13VK3, FV-08VK3, and FV-05VK3. Includes safety information, dimensions, wiring diagrams, operation details, and maintenance guidelines.
Preview Panasonic Ventilating Fan Installation and Operating Instructions
Comprehensive installation and operating instructions for Panasonic Ventilating Fans, including models FV-0510VSL1, FV-0510VSCL1, and FV-0810VSSL1. Covers safety information, features, installation steps for joist and wall mounting, maintenance, troubleshooting, specifications, and product service.
Preview Panasonic Ventilating Fan Installation and Maintenance Guide
Comprehensive installation, operation, and maintenance instructions for Panasonic Ventilating Fans, models FV-0811RFC1 and FV-0811RF2. Includes safety information, features, wiring diagrams, and warranty details.
Preview Panasonic Ventilating Fan Service Manual
Comprehensive service manual for Panasonic WhisperValue DC™ Ventilating Fans (FV-0510VSC1, FV-0810VSS1, FV-0510VSCL1, FV-0510VSL1, FV-0810VSSL1), detailing specifications, parts identification, wiring diagrams, and replacement parts lists for technicians.
Preview Panasonic FV-0511VK3 WhisperGreen Select Ventilating Fan Service Manual
This service manual provides detailed specifications, parts identification, wiring diagrams, and parts lists for the Panasonic FV-0511VK3 WhisperGreen Select Ventilating Fan.