Product Overview
The Shure A900-CM is a ceiling mount designed for specific Shure audio equipment. It has a maximum load capacity of 15 lb (6.8 kg). This product is manufactured by Peerless for Shure Incorporated.
General Warnings
⚠️ WARNING
This product is designed for use only with Shure MXA920W-S, MXA920W-S-60CM, MXA901W-S, MXA901W-S-60CM, MXA902W-S, MXA902W-S-60CM, MXA920W/B/AL-R. It is intended for installation on wood joist/beam or solid concrete ceilings. Ensure the supporting surface can support the combined load of the equipment and hardware. Screws must be tightly secured. Do not overtighten screws, as this can cause damage or product failure. Never exceed the Maximum Load Capacity. Always use an assistant or mechanical lifting equipment to safely lift and position the equipment. This product is intended for indoor use only; outdoor use may lead to product failure or personal injury. Be careful not to pinch fingers when operating the mount. For support, please call customer care at 1-800-865-2112.
Tools and Parts
Tools Needed for Assembly
- Pencil
- Drill ड्रिल
- Phillips Screwdriver ?
- 5/32" (4mm) drill bit
- Wrench ?
- 3/8" (10mm) socket
- Level ?
- 5/16" (8mm) wood screw
- Hammer ?
- 4mm allen wrench
Parts List
Before beginning, ensure you have all parts shown below.
Description | Qty | Part# |
---|---|---|
A ceiling plate | 1 | 10010122 |
B ceiling adaptor plate | 1 | 10009762 |
C M4 x 8mm screw | 4 | 520-2237 |
D #14 x 2-1/2" wood screw | 4 | 5S1-015-C04 |
E 8mm anchor | 4 | 590-0320 |
F 4mm allen wrench | 1 | 560-1145 |
Visual representation of parts:
- A (1): ceiling plate
- B (1): ceiling adaptor plate
- C (4): M4 x 8mm screw
- D (4): #14 x 2-1/2" wood screw
- E (4): 8mm anchor
- F (1): 4mm allen wrench
Installation Steps
The installation process involves preparing the mounting surface and then assembling the mount.
Step 1: Mounting Surface Preparation
Choose the appropriate sub-section based on your ceiling type.
1a: Wood joist/drywall
⚠️ WARNING
When installing on a wood joist/beam covered with gypsum board (drywall), verify that the joists or beams are a minimum of 2" x 4" nominal size. Do not install over gypsum board thicker than 5/8".
- 1a-1: Locate the joist or beam. Measure 1/2" (13mm) from the edge.
- 1a-2: Use the template (A) to mark mounting holes on the stud center lines.
- 1a-3: Drill mounting holes into the supporting surface using a 5/32" (4mm) drill bit. A minimum depth of 2.5" (64mm) is required. Ensure the mounting hole is centered on the stud.
- 1a-4: Install using the provided wood screws (D). Maximum torque: 80 in-lb (9 N.M.).
1b: Concrete Ceiling
⚠️ WARNING
When installing on a concrete ceiling, the ceiling must be at least 8" thick with a minimum compressive strength of 2000 psi. Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other finishing material.
- 1b-1: Use the template (A) to mark mounting holes.
- 1b-2: Drill mounting holes into the supporting surface using a 5/16" (8mm) drill bit. A minimum depth of 1.75" (45mm) is required.
- 1b-3: Insert anchor (E) flush to the concrete.
- 1b-4: Install using the concrete anchors (E) and wood screws (D). Maximum torque: 80 in-lb (9 Nm).
1c: Plywood
⚠️ WARNING
When installing on a wood joist/beam covered with plywood, verify that the wood joist/beam are a minimum of 2" x 4" nominal size and the plywood is a minimum Grade BC, 1/2" (13mm) thick. Plywood may be covered by gypsum board (drywall) up to 5/8" thick.
- 1c-1: Locate the joist or beam.
- 1c-2: Use the template (A) to mark mounting holes on the plywood.
- 1c-3: Drill mounting holes into the supporting surface using a 5/32" (4mm) drill bit. A minimum depth of 2.5" (64mm) is required. Ensure the mounting hole is centered on the stud.
- 1c-4: Install using the provided wood screws (D). Maximum torque: 80 in-lb (9 Nm).
1d: Wood joist
⚠️ WARNING
When installing on a wood joist/beam, verify that the wood joist/beams are a minimum of 2" x 4" nominal size.
- 1d-1: Use the template (A) to mark mounting holes.
- 1d-2: Drill mounting holes into the supporting surface using a 5/32" (4mm) drill bit. A minimum depth of 2.5" (64mm) is required. Ensure the mounting hole is centered on the stud.
- 1d-3: Install using the provided wood screws (D). Maximum torque: 80 in-lb (9 N.M.).
1e: Installation onto RACO125 Box
⚠️ WARNING
When installing on a wood joist/beam, verify that the joists/beams are a minimum of 2" x 4" nominal size. Do not install over gypsum board thicker than 5/8".
- 1e-1: Locate the joist or beam. Measure 1/2" (13mm) from the edge.
- 1e-2: Drill mounting holes into the supporting surface using a 5/32" (4mm) drill bit. A minimum depth of 2.5" (64mm) is required. Ensure the mounting hole is centered on the stud.
- 1e-3: Mark mounting holes on stud center lines.
- 1e-4: Note: RACO125 and hardware are not supplied by Peerless-AV. The length of the wood screw must be at least #10 x 1-1/4" plus the thickness of the drywall.
- 1e-5: Attach the A900-CM mount to the RACO125 electrical box. The maximum load capacity for this configuration is 20 lb (9 kg).
Step 2: Assembling the Mount
Follow the steps below based on your ceiling plate type.
2a: For Circular Ceiling Plate
- 2a-1: Attach the ceiling adaptor plate (B) to the ceiling plate (A) using screws (C).
- 2a-2: Use the 4mm allen wrench (F) to secure the assembly. Position the top mounting posts to the ceiling plate first, then position the bottom mounting posts and slide forward. Tighten.
2b: For Square Ceiling Plate
- 2b-1: Attach the ceiling adaptor plate (B) to the ceiling plate (A) using screws (C).
- 2b-2: Use the 4mm allen wrench (F) to secure the assembly. Position the top mounting posts to the ceiling plate first, then position the bottom mounting posts and slide forward. Tighten.
Declarations and Warranty
CE Marking: Shure Incorporated declares that this product with CE Marking has been determined to be in compliance with European Union requirements. The full text of the EU declaration of conformity is available at: https://www.shure.com/en-EU/support/declarations-of-conformity.
UKCA Marking: Shure Incorporated declares that this product with UKCA Marking has been determined to be in compliance with UK requirements. The full text of the UK declaration of conformity is available at: https://www.shure.com/en-GB/support/declarations-of-conformity.
For warranty information, please visit www.peerless-av.com/warranty.
Contact Information:
United States, Canada, Latin America, Caribbean:
Shure Incorporated
5800 West Touhy Avenue
Niles, IL 60714-4608 USA
Phone: 847-600-2000
Fax: 847-600-1212 (USA)
Fax: 847-600-6446
Email: info@shure.com
Europe, Middle East, Africa:
EU Importer / EU Rep.
Shure Europe GmbH
Jakob-Dieffenbacher-St. 12,
75031 Eppingen, Germany
Phone: +49-7262-92490
Fax: +49-7262-9249114
Email: info@shure.de
UK Importer / UK Rep.
Shure UK Limited
Unit 2, The IO Centre, Lea Road,
Waltham Abbey, Essex, EN9 1AS,
UK
Asia, Pacific:
Shure Asia Limited
22/F, 625 King's Road
North Point, Island East
Hong Kong
Phone: 852-2893-4290
Fax: 852-2893-4055
Email: info@shure.com.hk