Product Overview

The Shure A900-CM is a ceiling mount designed for specific Shure audio equipment. It has a maximum load capacity of 15 lb (6.8 kg). This product is manufactured by Peerless for Shure Incorporated.

General Warnings

⚠️ WARNING

This product is designed for use only with Shure MXA920W-S, MXA920W-S-60CM, MXA901W-S, MXA901W-S-60CM, MXA902W-S, MXA902W-S-60CM, MXA920W/B/AL-R. It is intended for installation on wood joist/beam or solid concrete ceilings. Ensure the supporting surface can support the combined load of the equipment and hardware. Screws must be tightly secured. Do not overtighten screws, as this can cause damage or product failure. Never exceed the Maximum Load Capacity. Always use an assistant or mechanical lifting equipment to safely lift and position the equipment. This product is intended for indoor use only; outdoor use may lead to product failure or personal injury. Be careful not to pinch fingers when operating the mount. For support, please call customer care at 1-800-865-2112.

Tools and Parts

Tools Needed for Assembly

  • Pencil
  • Drill ड्रिल
  • Phillips Screwdriver ?
  • 5/32" (4mm) drill bit
  • Wrench ?
  • 3/8" (10mm) socket
  • Level ?
  • 5/16" (8mm) wood screw
  • Hammer ?
  • 4mm allen wrench

Parts List

Before beginning, ensure you have all parts shown below.

DescriptionQtyPart#
A ceiling plate110010122
B ceiling adaptor plate110009762
C M4 x 8mm screw4520-2237
D #14 x 2-1/2" wood screw45S1-015-C04
E 8mm anchor4590-0320
F 4mm allen wrench1560-1145

Visual representation of parts:

  • A (1): ceiling plate
  • B (1): ceiling adaptor plate
  • C (4): M4 x 8mm screw
  • D (4): #14 x 2-1/2" wood screw
  • E (4): 8mm anchor
  • F (1): 4mm allen wrench

Installation Steps

The installation process involves preparing the mounting surface and then assembling the mount.

Step 1: Mounting Surface Preparation

Choose the appropriate sub-section based on your ceiling type.

1a: Wood joist/drywall

⚠️ WARNING

When installing on a wood joist/beam covered with gypsum board (drywall), verify that the joists or beams are a minimum of 2" x 4" nominal size. Do not install over gypsum board thicker than 5/8".

  • 1a-1: Locate the joist or beam. Measure 1/2" (13mm) from the edge.
  • 1a-2: Use the template (A) to mark mounting holes on the stud center lines.
  • 1a-3: Drill mounting holes into the supporting surface using a 5/32" (4mm) drill bit. A minimum depth of 2.5" (64mm) is required. Ensure the mounting hole is centered on the stud.
  • 1a-4: Install using the provided wood screws (D). Maximum torque: 80 in-lb (9 N.M.).

1b: Concrete Ceiling

⚠️ WARNING

When installing on a concrete ceiling, the ceiling must be at least 8" thick with a minimum compressive strength of 2000 psi. Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other finishing material.

  • 1b-1: Use the template (A) to mark mounting holes.
  • 1b-2: Drill mounting holes into the supporting surface using a 5/16" (8mm) drill bit. A minimum depth of 1.75" (45mm) is required.
  • 1b-3: Insert anchor (E) flush to the concrete.
  • 1b-4: Install using the concrete anchors (E) and wood screws (D). Maximum torque: 80 in-lb (9 Nm).

1c: Plywood

⚠️ WARNING

When installing on a wood joist/beam covered with plywood, verify that the wood joist/beam are a minimum of 2" x 4" nominal size and the plywood is a minimum Grade BC, 1/2" (13mm) thick. Plywood may be covered by gypsum board (drywall) up to 5/8" thick.

  • 1c-1: Locate the joist or beam.
  • 1c-2: Use the template (A) to mark mounting holes on the plywood.
  • 1c-3: Drill mounting holes into the supporting surface using a 5/32" (4mm) drill bit. A minimum depth of 2.5" (64mm) is required. Ensure the mounting hole is centered on the stud.
  • 1c-4: Install using the provided wood screws (D). Maximum torque: 80 in-lb (9 Nm).

1d: Wood joist

⚠️ WARNING

When installing on a wood joist/beam, verify that the wood joist/beams are a minimum of 2" x 4" nominal size.

  • 1d-1: Use the template (A) to mark mounting holes.
  • 1d-2: Drill mounting holes into the supporting surface using a 5/32" (4mm) drill bit. A minimum depth of 2.5" (64mm) is required. Ensure the mounting hole is centered on the stud.
  • 1d-3: Install using the provided wood screws (D). Maximum torque: 80 in-lb (9 N.M.).

1e: Installation onto RACO125 Box

⚠️ WARNING

When installing on a wood joist/beam, verify that the joists/beams are a minimum of 2" x 4" nominal size. Do not install over gypsum board thicker than 5/8".

  • 1e-1: Locate the joist or beam. Measure 1/2" (13mm) from the edge.
  • 1e-2: Drill mounting holes into the supporting surface using a 5/32" (4mm) drill bit. A minimum depth of 2.5" (64mm) is required. Ensure the mounting hole is centered on the stud.
  • 1e-3: Mark mounting holes on stud center lines.
  • 1e-4: Note: RACO125 and hardware are not supplied by Peerless-AV. The length of the wood screw must be at least #10 x 1-1/4" plus the thickness of the drywall.
  • 1e-5: Attach the A900-CM mount to the RACO125 electrical box. The maximum load capacity for this configuration is 20 lb (9 kg).

Step 2: Assembling the Mount

Follow the steps below based on your ceiling plate type.

2a: For Circular Ceiling Plate

  • 2a-1: Attach the ceiling adaptor plate (B) to the ceiling plate (A) using screws (C).
  • 2a-2: Use the 4mm allen wrench (F) to secure the assembly. Position the top mounting posts to the ceiling plate first, then position the bottom mounting posts and slide forward. Tighten.

2b: For Square Ceiling Plate

  • 2b-1: Attach the ceiling adaptor plate (B) to the ceiling plate (A) using screws (C).
  • 2b-2: Use the 4mm allen wrench (F) to secure the assembly. Position the top mounting posts to the ceiling plate first, then position the bottom mounting posts and slide forward. Tighten.

Declarations and Warranty

CE Marking: Shure Incorporated declares that this product with CE Marking has been determined to be in compliance with European Union requirements. The full text of the EU declaration of conformity is available at: https://www.shure.com/en-EU/support/declarations-of-conformity.

UKCA Marking: Shure Incorporated declares that this product with UKCA Marking has been determined to be in compliance with UK requirements. The full text of the UK declaration of conformity is available at: https://www.shure.com/en-GB/support/declarations-of-conformity.

For warranty information, please visit www.peerless-av.com/warranty.

Contact Information:

United States, Canada, Latin America, Caribbean:
Shure Incorporated
5800 West Touhy Avenue
Niles, IL 60714-4608 USA
Phone: 847-600-2000
Fax: 847-600-1212 (USA)
Fax: 847-600-6446
Email: info@shure.com

Europe, Middle East, Africa:
EU Importer / EU Rep.
Shure Europe GmbH
Jakob-Dieffenbacher-St. 12,
75031 Eppingen, Germany
Phone: +49-7262-92490
Fax: +49-7262-9249114
Email: info@shure.de

UK Importer / UK Rep.
Shure UK Limited
Unit 2, The IO Centre, Lea Road,
Waltham Abbey, Essex, EN9 1AS,
UK

Asia, Pacific:
Shure Asia Limited
22/F, 625 King's Road
North Point, Island East
Hong Kong
Phone: 852-2893-4290
Fax: 852-2893-4055
Email: info@shure.com.hk

Models: A900-CM Ceiling Mount, Ceiling Mount, A900-CM Mount, Mount, A900-CM

File Info : application/pdf, 20 Pages, 5.00MB

PDF preview unavailable. Download the PDF instead.

SHURE A900-CM (01)

References

Adobe PDF Library 16.0.7 Adobe InDesign 17.3 (Windows)

Related Documents

Preview Shure MXA920 Ceiling Array Microphone User Guide
This user guide provides comprehensive instructions for the Shure MXA920 Ceiling Array Microphone, covering installation, setup, software control (Designer, Web App), audio coverage configuration, IntelliMix DSP features, networking, and troubleshooting for professional audio environments.
Preview Shure MXA920 Ceiling Array Microphone User Guide
Comprehensive user guide for the Shure MXA920 Ceiling Array Microphone, covering installation, setup, software control, DSP, networking, and troubleshooting for professional audio environments.
Preview Shure A710-TB Tile Bridge Installation Guide for MXA710 Microphones
This guide provides detailed instructions for installing the Shure A710-TB Tile Bridge, a versatile accessory for mounting Shure MXA710 microphones in drop ceiling grids. It covers both 2-foot and 4-foot installations, including suspension and direct mounting. Learn about the contents of the kit, step-by-step procedures, and important safety information.
Preview Shure WL183M, WL184M, WL185M Lavalier Condenser Microphone User Guide and Specifications
Comprehensive user guide and technical specifications for Shure WL183M, WL184M, and WL185M lavalier condenser microphones, covering general description, model variations, installation, performance specifications, accessories, and wiring.
Preview Shure Professional Microphones and Audio Circuitry Products Catalog
Explore Shure's comprehensive catalog of professional audio equipment, including dynamic and condenser microphones for vocal, instrument, and specialty applications, wireless microphone systems, and advanced audio circuitry products like mixers and problem solvers. Discover Shure's commitment to quality, reliability, and innovative sound solutions for professionals worldwide.
Preview Shure R131 and R132 Replacement Cartridge User Guide
User guide for Shure R131 and R132 replacement dynamic cartridges, providing step-by-step instructions for installation and internal connection diagrams for the Model 527B and 527C microphones.
Preview Shure SRH440A Professional Studio Headphones User Guide
User guide for Shure SRH440A Professional Studio Headphones, detailing features, specifications, care, safety, warranty, and service information.
Preview Shure MXA-MUTE Network Mute Button User Guide | Installation & Configuration
Comprehensive user guide for the Shure MXA-MUTE Network Mute Button. Learn about installation, configuration with Shure Designer, compatible devices, specifications, and safety information for professional audio systems.