Field-Oriented Spectrophotometer for Reliable Color Measurement
Konica Minolta's CM-700d/600d spectrophotometers are designed for users who require accurate and reliable color measurement in diverse environments. These instruments offer unprecedented ease of handling and operation, enhanced by a user-friendly color LCD screen.
Key Features and Benefits
Perfect Design to Fit in Your Hand
- Ergonomic, compact, and lightweight design for comfortable use.
- Vertical format allows for easy positioning during measurements.
- Excellent portability makes them ideal for production sites and field use.
Measure Anywhere!
The tapered measuring head facilitates easy checking of measurement positions. The upright design ensures straightforward measurement, even on concave surfaces. The CM-700d model offers selectable measuring apertures (Ø8 mm and Ø3 mm) to accommodate various sample sizes.
Easy to Operate!
Dedicated buttons for frequently used operations provide quick access to menus and target colors. The intuitive menu-driven display ensures that anyone can operate the instrument with ease.
Easy-to-Read Color LCD Screen!
Abundant information is displayed in color for clear understanding. Measured colors can be reproduced as color patches on the LCD, aiding in the visual assessment of color differences or color searching.
Bluetooth® Compatible!
Data can be wirelessly transmitted to a PC or a mobile printer via Bluetooth® communication. USB communication with a PC is also supported.
Automatic Switching for SCI and SCE Measurement
The instruments automatically switch between Specular Component Included (SCI) and Specular Component Excluded (SCE) measurement modes.
Large Memory Capacity
Stores up to 1,000 target data sets and 4,000 measurement data sets.
Color Data Software SpectraMagic NX
The optional SpectraMagic NX software (CM-S100w) enhances color management capabilities. It allows users to create custom screens tailored to specific applications by arranging various objects such as data lists, spectral graphs, color difference graphs, and Pass/Fail displays. This enables the generation of detailed inspection reports after measurements.
System Requirements for SpectraMagic NX:
- OS: Windows® 7 Professional (32/64-bit), Windows® 8.1 Pro (32/64-bit), Windows® 10 Pro (32/64-bit)
- CPU: Pentium® III 600 MHz equivalent or faster
- Memory: 128 MB or more (256 MB or more recommended)
- Hard disk: 450 MB or more of free space for installation
- Display: Resolution: 1,024 x 768 dots or more / 16-bit colors or more
- Other: DVD-ROM drive (for installation), one free USB port (for protection key), one free port (serial or USB) for instrument connection (or USB for Bluetooth adapter), Internet Explorer Version 5.01 or later.
Note: System hardware must meet or exceed recommended specifications for the OS and above. Windows® and Pentium® are trademarks of Microsoft Corporation and Intel Corporation, respectively.
System Overview and Accessories
The system includes the CM-700d/600d spectrophotometer, AC adapter, and wrist strap. Connectivity options include Bluetooth® and USB. Optional accessories enhance functionality and usability.
System Diagram Description:
The system diagram illustrates the connection of the CM-700d/600d spectrophotometer to an AC adapter for power. It shows optional connectivity to a commercially available Bluetooth® printer or a Bluetooth® adapter, which then connects to a PC. A USB cable (IF-A36, 2m) is also shown for direct PC connection. The diagram also lists various standard and optional accessories.
Standard Accessories:
- White Calibration Cap
- Zero Calibration Box
- Dust Cover Set
- Target Masks (Ø8 mm with glass)
Optional Accessories:
- Target Masks: Ø8 mm (with plate), Ø8 mm (without plate), Ø3 mm (with plate), Ø3 mm (without plate)
- Replacement Dust Cover (Polyolefine)
- Granular-Materials Attachment (for CM-700d/600d)
- Hard Case (for storage)
Main Specifications
Specification | CM-700d | CM-600d |
---|---|---|
Illumination/viewing system | di: 8°, de: 8° (diffused illumination, 8-degree viewing angle), SCI/SCE selectable with automatic switching (Conforms to CIE No. 15, ISO 7724/1, DIN5033 Teil 7, ASTM E 1164, and JIS Z 8722) | |
Integrating sphere size | Ø40 mm | |
Detector | Silicon photodiode array (dual 36-element) | |
Spectral separation device | Diffraction grating | |
Wavelength range | 400 nm to 700 nm | |
Wavelength pitch | 10 nm | |
Half bandwidth | Approx. 10 nm | |
Reflectance range | 0 to 175%, Display resolution: 0.01% | |
Light source | Pulsed xenon lamp (with UV cut filter) | |
Measurement time | Approx. 1 second | |
Minimum measurement interval | Approx. 2 seconds (in SCI or SCE mode) | |
Battery performance | With alkaline dry batteries: Approx. 2,000 measurements (Stand-alone continuous measurement fixed to either SCI or SCE mode at 10-second intervals at 23°C) | |
Measurement/illumination area | MAV: Ø8 mm/ Ø11 mm SAV: Ø3 mm/ Ø6 mm (Changeable by replacing target mask and selecting lens position) | MAV: Ø8 mm/ Ø11 mm only |
Repeatability | Spectral reflectance: Standard deviation within 0.1%, Chromaticity value: Standard deviation within ΔE*ab 0.04 (When a white calibration plate is measured 30 times at 10-second intervals after white calibration) | |
Inter-instrument agreement | Within ΔE*ab 0.2 (MAV/SCI) * Based on 12 BCRA Series II color tiles compared to values measured with a master body at 23°C | |
No. of averaging measurements | 1 to 10 (Auto averaging), 1 to 30 (Manual averaging) | |
Display | 2.36-inch TFT color LCD | |
Interface | USB1.1; Bluetooth® standard version 2.1+EDR* | |
Observer | 2° or 10° Standard Observer | |
Illuminant | A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (Simultaneous evaluation with two light sources possible) | |
Displayed data | Spectral values/graph, colorimetric values, color difference values/graph, PASS/FAIL result, pseudocolor, color assessment | |
Colorimetric data | L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, Munsell, and color difference in these spaces (except for Munsell) | |
Index | MI, WI(ASTM E313-73/E313-96), YI(ASTM E313-73/ASTM D1925), ISO Brightness, 8° gloss value | |
Color difference formulas | ΔE*ab (CIE 1976), ΔE*94 (CIE 1994), ΔE00 (CIE DE2000), CMC (l: c), Hunter ΔE | |
Data memory | Measurement data: 4,000 sets/Target color difference data: 1,000 sets | |
Pass/Fail judgment | Tolerances can be set to colorimetric values (excluding Munsell), color difference values, color values (excluding 8° gloss value) respectively | |
Power | Special AC Adapter; 4 AA-size alkaline dry batteries or nickel-metal-hydride rechargeable batteries | |
Size (W x H x D) | 73 x 211.5 x 107 mm | |
Weight | Approx. 550 g (without white calibration cap and batteries) | |
Operation temperature/ humidity range | 5 to 40°C, relative humidity 80% or less (at 35°C) with no condensation | |
Storage temperature/ humidity range | 0 to 45°C, relative humidity 80% or less (at 35°C) with no condensation |
* Applicable Bluetooth® profile: Serial Port Profile, Output: Bluetooth® Power Class 1. Communication distance may vary. Successful wireless communication is not guaranteed with all Bluetooth®-ready equipment. Bluetooth® is a registered trademark of Bluetooth SIG, Inc.
Dimensions (Units: mm): Width: 73 mm, Height: 211.5 mm, Depth: 107 mm. Aperture sizes include Ø8 mm and Ø3 mm options.
Safety Precautions
Users must read the instruction manual before operating the instrument. Ensure the instrument is connected to the specified power supply voltage and only use specified batteries to prevent fire or electric shock.
Company Information and Certifications
Konica Minolta, Inc. and its subsidiaries provide global support. The company holds ISO 9001 and ISO 14001 certifications for its quality and environmental management systems at its Sakai Site, covering the design, development, manufacture, calibration, and service of measuring instruments.
Contact Information (Examples):
- Konica Minolta Sensing Americas, Inc. (New Jersey, U.S.A.)
- Konica Minolta Sensing Europe B.V. (Nieuwegein, Netherlands)
- Konica Minolta (CHINA) Investment Ltd. (Beijing, China)
- And various other regional offices.
Specifications and appearance are subject to change without notice.