OTP-C Champagne Ductless Single Zone Heat Pump
Performance
Cooling
- Up to -18°C (0°F)
Heating
- Up to -25°C (-13°F)
Energy Efficiency
- Up to 23 SEER in Cooling
- 10.5 HSPF in Heating
Features
Operation Mode
Cooling, heating, dehumidifying, fan, and auto.
Nominal Capacity
9000, 12000, 18000, 24000 BTU/hr.
Voltage
230/208V, 60 Hz, 1-phase.
Indoor Unit
- High wall installation, dual side connection.
- Plastic housing, standard white.
- 4-speed cross-flow fan (turbo, high, medium, and low).
- Washable filters.
Outdoor Unit
- Variable speed rotary compressor (INVERTER), with overload protection.
- Electronic expansion valve for precise control of refrigerant flow.
- Condenser fins covered with a hydrophilic coating for improved corrosion resistance.
- Large diameter quiet axial-flow fan for more efficient heat exchange.
- Smart pan heater to prevent ice formation.
- Compressor blanket and preheating technology.
- Installation on epoxy/polyester powder coated adjustable steel wall bracket (optional).
Connection Piping
- Minimum piping length of 10 ft. (3 m).
- Flared connections.
Control
- Wireless remote included.
- Wired wall controller available.
- Wi-Fi capability (option KIT-WIFI required).
- Set temperature: 16 to 30 °C (61 to 86 °F).
- Temperature display format: °C or °F.
Warranty
Note: All heat pump systems must be installed and registered by a certified Ouellet installer to be covered by the basic warranty.
- 5-year basic warranty on parts and 5-year basic warranty on the compressor (labour not included).
Sold Separately
- Extended warranty from the 1st to 5th year, parts and labour.
- Extended warranty from the 1st to 10th year, parts and labour with system replacement if the compressor fails.
Application
- Dining room-kitchen, living room, family room, commercial building, office building, condo, restaurant.
Includes
- ♨️ Smart Pan Heater
- ⚙️ Crankcase Heater
- ?️ Fin Coating
- ? Quiet Design
- ❄️ Smart Defrosting
- ? Smart Preheating
- ? Auto Restart
- ✨ Auto-Clean
Optional
- ?️ Wall Controller
- ? Self Diagnosis
- ? Sleep Mode
- ? Turbo Mode
- ↕️ Up & Down Swing
- ⏱️ Timer
- ?️ I Feel
- ? Lock
- ? Wireless Remote
- ? Wi-Fi
Technical Performance Summary
Model | Nominal Cooling Capacity (BTU/hr) | Nominal Heating Capacity (BTU/hr) | SEER | HSPF |
---|---|---|---|---|
OCD09KCH23S | 9000 | 3100-9600 | 23 | 10.5 |
OCD12KCH22S | 12000 | 3100-13000 | 22 | 10.1 |
OCD18KCH20S | 18000 | 6800-20000 | 20 | 10 |
OCD24KCH20S | 22000 | 6824-27296 | 20 | 10 |
Options
Product # | Description |
---|---|
OTP-WB3 | Adjustable wall bracket for outdoor unit |
OTP-WBRC-OCD | Wall bracket for wireless remote, OTP-C Series |
KIT-WIFI | Wi-Fi kit |
OTP-XK76 | Programmable wired wall controller |
Dimensions
Indoor Unit Dimensions
Diagrams show Front View, Side View, and Back View with labels L (Length), H (Height), D (Depth), A, B, C (mounting points).
Model | L (in./mm) | H (in./mm) | D (in./mm) | A (in./mm) | B (in./mm) | C (in./mm) |
---|---|---|---|---|---|---|
OCD09KCH23S-I | 33 1/4 / 845 | 11 3/8 / 289 | 8 1/4 / 209 | 4 11/16 / 119 | 21 5/16 / 542 | 7 1/4 / 184 |
OCD12KCH22S-I | 38 3/16 / 970 | 11 13/16 / 300 | 8 13/16 / 224 | 4 / 102 | 27 / 686 | 7 3/16 / 183 |
OCD18KCH20S-I | 42 7/16 / 1078 | 12 13/16 / 325 | 9 11/16 / 246 | 8 1/8 / 206 | 27 / 686 | 7 5/16 / 186 |
Outdoor Unit Dimensions
Diagrams show Front View, Side View, and Top View with labels L (Length), H (Height), D (Depth), A, B (mounting points).
Model | L (in./mm) | H (in./mm) | D (in./mm) | A (in./mm) | B (in./mm) |
---|---|---|---|---|---|
OCD09KCH23S-O | 33 3/8 / 848 | 21 1/4 / 540 | 12 5/8 / 320 | 21 1/4 / 540 | 11 1/4 / 286 |
OCD12KCH22S-O | 33 3/8 / 848 | 23 5/16 / 592 | 12 5/8 / 320 | 21 1/4 / 540 | 11 1/4 / 286 |
OCD18KCH20S-O | 37 5/8 / 955 | 27 9/16 / 700 | 15 9/16 / 396 | 22 / 559 | 14 5/16 / 364 |
OCD24KCH20S-O | 38 9/16 / 980 | 31 1/8 / 790 | 16 13/16 / 427 | 24 / 610 | 15 9/16 / 395 |
Adjustable Wall Bracket Dimensions
Diagram shows the bracket with labels L (Length), H (Height), D (Depth).
Product # | L (in./mm) | H (in./mm) | D (in./mm) | Maximum Capacity (lb/kg) |
---|---|---|---|---|
OTP-WB3 | 33 1/2 / 850 | 17 3/4 / 450 | 21 11/16 / 550 | 500 / 227 |
Capacity Variation Ratio According to Temperature
These graphs illustrate how the cooling and heating capacity ratio changes with outdoor temperature for different model series.
OCD09 & OCD12 Series
- Cooling: Shows capacity ratio from 89°F to 109.4°F outdoor temperature. Conditions: Indoor DB 80°F WB 66.9°F, Outdoor DB 95°F, Indoor air flow: High, Pipe length: 24.6 ft.
- Heating: Shows capacity ratio from 5°F to 50°F outdoor temperature. Conditions: Indoor DB 70°F WB 60°F, Outdoor DB 19.94°F WB 19.04°F, Indoor air flow: High, Pipe length: 24.6 ft.
OCD18 & OCD24 Series
- Cooling: Shows capacity ratio from 89.6°F to 109.4°F outdoor temperature. Conditions: Indoor DB 80°F WB 66.9°F, Outdoor DB 95°F, Indoor air flow: Turbo, Pipe length: 24.6 ft.
- Heating: Shows capacity ratio from -4°F to 50°F outdoor temperature. Conditions: Indoor DB 70°F, Outdoor DB 19.94°F WB 19.04°F, Indoor air flow: Turbo, Pipe length: 24.6 ft.