Kospel EKCO.M3 & EKCO.MN3 Electric Boilers

Installation and Operation Instructions

Explanation of Symbols

⚠️ Warning: Follow safety instructions carefully to avoid injury and damage.

❗ Danger: This symbol warns of the risk of injury.

❗ Note: This symbol warns of property damage and environmental pollution.

? Tip: Text marked with "Tip" contains additional information.

Target Audience

This manual is intended for product users. The product can be used by children aged 3 and above, and persons with physical, sensory, or mental deficiencies, or inexperienced users, provided they have received instructions for safe operation and understand the associated risks. This product is not a toy. Children can clean and maintain this product only under adult supervision.

Only qualified electricians are permitted to repair electrical components. The initial installation of this product must be performed by an installer or a designated authorized person.

Applicable Legislation and Regulations

Safety Instructions

General Safety:

⚠️ Danger: Incorrect connection work can lead to fatal accidents. Work on the devices can only be performed by a qualified installer.

Working with this product:

❗ Note: The device can only be used when correctly installed and in perfect technical condition.

Product Overview

The EKCO.M3 and EKCO.MN3 electric central heating boilers are designed for heating domestic spaces equipped with underfloor heating systems using water or antifreeze as the heat transfer medium. The boiler should be selected based on the building's thermal balance.

The boiler is a low-temperature type, operating in closed water heating systems with forced water circulation, compliant with PN-B-02414:1999. It can also operate in open water heating systems with forced water circulation, compliant with PN-B-02413:1991. The boiler operates in an automatic cycle with minimal operational duties.

Intended Use

The device is intended exclusively for domestic or similar use. Commercial or industrial use leading to excessive device operation is contrary to its intended purpose. Improper use or negligent handling voids the manufacturer's warranty. Improper use includes altering the intended function of the heating system components.

? Tip: The device is designed for domestic or similar use, meaning even untrained individuals can operate it safely.

Main Product Features

The device is equipped with several safety features to protect against installation-related faults:

The boiler is equipped with: circulation pump, pressure sensor, diaphragm expansion vessel (for EKCO.MN3 only), automatic air vent, and safety valve.

Construction

The boiler's internal components include:

Assembly and Installation

General Installation:

  1. Install the boiler vertically on a flat wall using fixing screws or the included bracket, with outlets facing downwards. Maintain minimum distances from walls and ceiling. Fasteners must be adapted to the substrate type, considering the device's weight.
  2. Connect the boiler to the central heating system equipped with shut-off valves. Valves should be located directly on the boiler.
  3. Fill the central heating system with water or antifreeze suitable for central heating systems, which significantly affects the heating elements' durability.
  4. Vent the central heating system.
  5. Connect the boiler to the electrical installation as described on page 9.
  6. Install and connect the room temperature sensor (Tr) and outdoor temperature sensor (Tos) as described on page 11.
  7. After completing the above steps, start the boiler, set the language and maximum boiler output, and perform pump venting [Configuration > Pump > CH venting / DHW venting].
  8. Set the maximum medium temperature in the installation [Configuration > Central heating > Max. boiler temp.].
  9. Adapt the boiler's operation to the building's heating system and user preferences – refer to the Settings and Configuration chapters.

Installation Notes:

The EKCO.MN3 boilers are equipped with a 5-liter expansion vessel (1.5 bar pressure). This vessel is sufficient for the following heating system capacities at given medium temperatures and central heating system pressures:

Heating Medium Temperature (°C) (Suction and Return) Central Heating System Capacity [l] Central Heating System Pressure [bar]
85/70 56 1.5
70/55 80
55/45 127
50/40 153
45/35 188

If the liquid capacity of the central heating installation is larger, an additional expansion vessel must be installed according to the applicable standard.

Connecting the Boiler to the Central Heating System

Diagrams illustrating the connection of the boiler to the central heating system are provided, showing various components such as:

The filter must be installed so that the flow direction of the heating medium matches the arrow cast on the casing, with the cover at the bottom. Filters can be installed in horizontal or vertical pipes. It is recommended to use shut-off valves immediately before and after the filter for easier cleaning and replacement of the filter insert.

Boiler Connection Diagrams to Electrical Installation

Depending on the purchased boiler model and the space's electrical installation, the boiler must be connected according to the following diagrams:

Boiler Configuration

Before powering on, ensure the switch settings are compatible with the boiler model and installation type.

Switch Settings and Nominal Power/Installation Type:

Operation Settings:

Connecting External Control Signals

❗ Note: Do not connect any voltage to the FN, MA, RT, Tcyl, Tos, Tr inputs! This can cause permanent damage to the controller.

Input Symbol and Function:

RS485 Communication Bus

Diagrams show connections for the C.MI2 internet module, C.MG3 heating module, and cascade boiler systems.

❗ Note: Each device connected to the communication bus must have a unique identification number (except C.MI2). The maximum number of devices that can be parameterized in the system is 32.

Actuator Connections

Control Panel

The control panel consists of:

Main Screen:

The main screen displays:

Error Indication: The boiler error is indicated by the ERR icon on the main screen. Pressing the navigation switch [2] displays the list of detected errors.

Heating Programs

The boiler allows for setting daily and weekly heating programs for both central heating (CH) and domestic hot water (DHW).

Turbo Operation:

Turbo mode provides rapid heating by using maximum parameters until the set room temperature is reached. It can be activated automatically if the room temperature drops below a set threshold or manually via the quick modes menu. DHW priority can be disabled during Turbo operation.

Frost Protection:

The building frost protection function prevents significant cooling of the building. The CH system activates if the outdoor temperature drops below 2°C or the room temperature drops below 5°C. This function is deactivated if the boiler is controlled by an external room controller connected to the RT input.

Technical Data

Parameter Unit Value
Maximum pressure MPa 0.3 (3 bar)
Minimum pressure MPa 0.05 (0.5 bar)
Flow outlet temperature °C 20 ÷ 85
Maximum temperature °C 100
Dimensions (H x W x D) EKCO.MN3 (mm) 716 x 316 x 235
EKCO.M3 (mm) 716 x 316 x 191
Weight EKCO.MN3 (kg) ~20.5
EKCO.M3 (kg) ~15.8
Boiler Connections G 3/4" (internal thread)
Expansion Vessel EKCO.MN3 (l) ~5
Protection Class IP 22

Boiler Specifications:

Boiler 4 / 6 / 8 400V 3N~
Nominal Power kW 2 4 6 8 4 6 8
Nominal Voltage 230V~ 400V 3N~
Nominal Current A 8.7 17.4 26.1 34.8 3x5.8 3x8.7 3x11.6
Min. supply cable cross-section mm² 3x2.5 3x4 3x6 5x2.5
Max. supply cable cross-section mm² 5 x 16
Max. permissible network resistance Ω 0.27 0.17 0.15 0.27
Boiler 12 / 16 / 20 / 24
Nominal Power kW 12 16 20 24
Nominal Voltage 400V 3N~
Nominal Current A 3x17.4 3x23.1 3x28.8 3x34.6
Min. supply cable cross-section mm² 5 x 2.5 5 x 4 5 x 6
Max. supply cable cross-section mm² 5 x 16
Max. permissible network resistance Ω 0.27 0.13
Boiler 9 / 12 / 15 / 18
Nominal Power kW 9 12 15 18
Nominal Voltage 230V 3~
Nominal Current A 22.6 30.1 37.6 45.2
Min. supply cable cross-section mm² 3X4 3X6 3 x 16 3 X 10
Max. supply cable cross-section mm²
Max. permissible network resistance Ω 0.3 0.25 0.18 0.13
Boiler 7 / 9 / 11 / 14
Nominal Power kW 6.6 8.8 11 13.2
Nominal Voltage 230V~
Nominal Current A 28.7 32.3 47.8 57.4
Min. supply cable cross-section mm² 3 X 6 3 x 16 3 X 10
Max. supply cable cross-section mm²
Max. permissible network resistance Ω 0.25 0.20 0.16 0.13

Product Disassembly

Disassembly of the central heating boiler must be performed in the reverse order of assembly described on page 7.

Package Contents

Packaging Disposal

This product bears the WEEE symbol, indicating it should not be disposed of with mixed household waste. Return the product to a WEEE collection point for recycling. Proper disposal prevents potential environmental harm.

For more information on recycling, contact local authorities, waste management organizations, or the original seller.

Declaration of Conformity: Standards and Reference Directives

KOSPEL Sp. z o.o. declares that the Electric Boilers mentioned in this manual comply with the requirements of the Directives and relevant safety standards for electrical appliances for domestic use: LVD (2014/35/EU) and EMC (2014/30/EU). The products are marked with the CE symbol.

The full text of the declaration of conformity is available on the manufacturer's website: www.kospel.pl.

PDF preview unavailable. Download the PDF instead.

Οδηγίες-εγκατάστασης-ηλεκτρικού-λέβητα-Kospel-EKCO-M3 GPL Ghostscript 10.05.0 Adobe InDesign 18.1 (Windows)

Related Documents

Preview KOSPEL EKCO.L3/EKCO.LN3 Electric Central Heating Flow Boiler: Assembly and Operating Instructions
Comprehensive assembly and operating instructions for the KOSPEL EKCO.L3 and EKCO.LN3 electric central heating flow boilers, covering safety, installation, electrical connections, control panel functions, and technical specifications.
Preview Kospel EKCO.L3 Electric Central Heating Flow Boiler Assembly and Operating Instructions
Comprehensive assembly and operating instructions for the Kospel EKCO.L3 Electric Central Heating Flow Boiler, covering installation, safety, technical specifications, and control panel functions.
Preview KOSPEL Product Catalog 2025/1: Advanced Heating Solutions
Discover KOSPEL's extensive range of heating and hot water solutions, including high-efficiency heat pumps, electric boilers, and water heaters. Featuring 35 years of expertise, KOSPEL offers innovative products for optimal home comfort and energy savings.
Preview KOSPEL Catalogue 2025 : Pompes à Chaleur, Chaudières Électriques et Chauffe-eau
Découvrez le catalogue produits 2025 de KOSPEL, leader européen des solutions de chauffage. Présentation des pompes à chaleur, chaudières électriques, chauffe-eau et ballons pour un confort thermique optimal.
Preview KOSPEL KDE3 & KDE5 Electric Instantaneous Water Heater - Installation and Operation Manual
Comprehensive guide for KOSPEL KDE3 and KDE5 electric instantaneous water heaters, covering installation, operation, safety, maintenance, and technical specifications. Includes multilingual safety information and operational details.
Preview Kospel SVK Buffer Tank User Manual and Technical Specifications
Comprehensive guide for the Kospel SVK buffer tank, covering application, installation, operation, safety, troubleshooting, and technical data. Available in multiple languages.
Preview Kospel SWPC 300L Water Heater Manual
Installation, operation, and technical specifications for the Kospel SWPC 300L domestic hot water cylinder.
Preview Kospel SW Vertical Hot Water Cylinders - Technical Specifications and Features
Explore the Kospel SW series of vertical hot water cylinders, featuring advanced technology, unbeatable quality, and detailed technical specifications for efficient heating solutions.