Quick Start for the InTemp® CX405 RTD Dry Ice Logger

Monitoring Solutions

1 Administrators: Set up an InTempConnect® account.

Note: If you are using the logger with the InTemp app only, skip to step 2.

New administrators: Follow all steps. Need to just add a new user? Follow steps c and d.

  1. Go to www.intempconnect.com and follow the prompts to set up an administrator account. You'll receive an email to activate the account.
  2. Log into www.intempconnect.com and add roles for the users you will be adding to the account. Click Settings and then Roles. Click Add Role, enter a description, select the privileges for the role and click Save.
  3. Click Settings and then Users to add users to your InTempConnect account. Click Add User and enter the email address and first and last name of the user. Select the roles for the user and click Save.
  4. New users will receive an email to activate their user accounts.

2 Install the batteries.

Install two AAA batteries in the logger, observing polarity. Insert the battery door in the back of the logger making sure it is flush with the rest of the logger case. Use the included screw and a Phillips-head screwdriver to screw the battery door into place.

Document ID: 25468-E MAN-QSG-CX405

3 Download the InTemp app and log in.

  1. Download InTemp to a phone or tablet.
  2. Open the app and enable Bluetooth® in the device settings if prompted.
  3. InTempConnect users: Log in with your InTempConnect account email and password from the InTempConnect User screen.

InTemp app only users: Swipe left to the Standalone User screen and tap Create Account. Fill in the fields to create an account and then log in from the Standalone User screen.

4 Configure the logger.

InTempConnect users: Configuring the logger requires privileges. The logger includes preset profiles. Administrators or those with the required privileges can also set up custom profiles (including setting up daily logger checks) and trip information fields. This should be done before configuring the logger. If you plan to use the logger with the InTempVerify™ app, then you must create a profile with InTempVerify enabled. For details, see www.intempconnect/help.

InTemp app only users: The logger includes preset profiles. To set up a custom profile, tap the Settings icon and tap CX400 Logger. Also, if you need to perform daily logger checks, tap

(continued)

4 (continued)

Record CX400 Logger Checks under Settings and select Once Daily or Twice Daily. This should be done before configuring the logger.

  1. Tap the Devices icon in the app. Find the logger in the list and tap it to connect to it. If the logger does not appear, make sure it is within range of your device.
  2. Once connected, tap Configure. Swipe left and right to select a logger profile. Type a name for the logger. Tap Start to load the selected profile to the logger. InTempConnect users: If trip information fields were set up, you will be prompted to enter additional information. Tap Start in the upper right corner when done. Note: You can also configure the logger from InTempConnect via the CX5000 Gateway. See www.intempconnect.com/help for details.

5 Deploy and start the logger.

Deploy the logger to the location where you will be monitoring the temperature. Logging will begin based on the settings in the profile selected. If the logger was configured to perform daily checks, connect to the logger and tap Perform Check (Morning, Afternoon, or Daily) every day.

6 Download the logger.

Using the InTemp app, connect to the logger and tap Download. A report is saved in the app. Tap the Reports icon to view and share downloaded reports. To download multiple loggers at once, tap Bulk Download on the devices tab.

InTempConnect users: Privileges are required to download, preview, and share reports in the app. Report data is automatically uploaded to InTempConnect when you download the logger. Log into InTempConnect to build custom reports (requires privileges).

Note: You can also download the logger using the CX5000 Gateway or the InTempVerify app. See www.intempconnect.com/help for details.

For more information on using the logger and the InTemp system, go to www.intempconnect.com/help or scan the code at left.

Models: CX405 RTD Dry Ice Logger, CX405, RTD Dry Ice Logger, Dry Ice Logger, Dry Ice, RTD Logger

File Info : application/pdf, 1 Pages, 275.13KB

PDF preview unavailable. Download the PDF instead.

25468-E MAN-QSG-CX405-web

References

Acrobat Distiller 22.0 (Windows)

Related Documents

Preview Quick Start Guide for InTemp CX405 RTD Dry Ice Logger
A quick start guide to setting up, configuring, and deploying the InTemp CX405 RTD Dry Ice Logger, including account setup, battery installation, app download, and data logging.
Preview InTemp CX500 Series Loggers Quick Start Guide | Onset
Get started quickly with your InTemp CX500 Series temperature data loggers. This guide covers account setup, app download, logger configuration, deployment, and data download using InTempConnect and the InTemp app.
Preview Quick Start Guide for InTemp CX1000 Series Loggers
This guide provides step-by-step instructions for setting up, registering, deploying, and completing shipments with Onset's InTemp CX1000 Series data loggers using the InTempConnect platform.
Preview InTemp CX450 Temperature and Relative Humidity Data Logger User Manual
Comprehensive user manual for the InTemp CX450 Temperature/RH data logger, detailing its features, specifications, setup, operation, and regulatory compliance for monitoring temperature and humidity in critical environments.
Preview Onset Conductivity Assistant: Calculating Specific Conductance with Sea Water
A technical guide detailing the calculations performed by the Onset Conductivity Assistant (Version 2.1) for determining specific conductance and salinity in sea water, including revised non-linear temperature compensation methods and data tables.
Preview HOBO MX801 Submersible Logger Quick Start Guide
A quick start guide for the HOBO MX801 Submersible Logger, detailing its overview, sensor connection, calibration, configuration, deployment, data download, and processing.
Preview HOBO Pendant Temperature Data Logger UA-001-xx User Manual
Comprehensive user manual for the Onset HOBO Pendant Temperature Data Logger (models UA-001-08 and UA-001-64), detailing specifications, connection, setup, operation, alarm configuration, and battery replacement.
Preview HOBO Pendant G Acceleration Data Logger - User Manual
Comprehensive guide to the HOBO Pendant G Acceleration Data Logger, covering its features, specifications, operation, connection, logging modes, mounting, protection, battery replacement, and support. Includes details on measurement ranges, accuracy, logging intervals, temperature ratings, and warranty information.