User Manual for NEO models including: 12 LEDS 6-IN-1 X 12W Professional Led Washer, 12 LEDS 6-IN-1 X 12W, Professional Led Washer, Led Washer, Washer
Macaio | Shield IP 12 KIT - Macaio
SHIELD IP12 PROFESSIONAL LED WASHER - 12 LEDS 6-IN-1 X 12W USER MANUAL | MANUAL DE USUARIO PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE USE POR FAVOR LEA LAS INSTRUCCIONES ANTES DE USAR P. 1 Versión Español | Tecshow NEBULA PAR 162 II 1. MENU First Level Menu Second Level Menu Third Level Menu Description 1. DMX 2. Manual 4. Program 5. Slave 6. Settings 7. Information Address: Channels: 1. Red: 001-512 6/8/13-CH 000~255 DMX Address DMX Mode Manual Adjustment Mode 2. Green: 3. Blue: 4. White: 5. Amber: 6. UV: 3. Auto Mode: Color (Mode: 1): Speed (Mode: 2-16): Strobe: Yes/No 1. Curves Select 2. Dimmer Speed 3. Display 4. PWM Frequency 5. DMX Fail 000~255 000~255 000~255 000~255 000~255 Yes/No 1-16 1-33 1-100 (81) 0-99 1-4 (2) Fast/Smooth Normal/Inverted 12K/6K/3K/1K Off/Hold/Manual/Program Auto Mode Built-in Program Mode Built-in Program Static Color Built-in Program Speed Built-in Program Strobe Slave Mode Dimmer Curve Selection Dimmer Speed Selection Display Direction Setting PWM Frequency Setting DMX Signal Option 6. Backlight Time 5s/10s/20s/30s/ON Backlight Time Setting 7. Lock 8. Key Backlight On/Off On/Off 9. Factory Yes/No Version: x.x Temperature: xx Life Time: xxxx h UID: xxxxxxxxxxxx Standby Screen Lock Key Backlight Setting Restore Factory Settings Version Display Temperature Detection Operating Time Light Fixture UID P. 2 English Version | NEO- Shield IP12 2. DMX CHANNEL Function DMX Value Setting 6-Ch 8-Ch 13-Ch 32-Ch 39-Ch Dimmer Strobe Linear 11-255 Strobe FX 11-255 Red Green Blue White Amber UV Color preset 000-255 0~100% 0-10 Slow to fast linear strobe 0-10 Slow to fast random strobe 000-255 000-255 000-255 000-255 000-255 000-255 000-007 No function No function 0~100% 0~100% 0~100% 0~100% 0~100% 0~100% No function 1 1 1 2 2 2 3 1 3 7 2 4 8 3 5 9 4 6 10 5 7 11 6 8 12 4 PRODUCT OPERATION AND WORKING MODE INSTRUCTIONS Switching Working Modes: Press MODE or UP or DOWN to switch between menus. DMX Manual Auto Program Slave Settings Information Working Mode Descriptions: a. DMX Mode: This is the DMX mode. Press SETUP to enter. Use the UP/DOWN keys to select as follows: DMX Address: 001~512 Channels: 6/8/13-ch b. Manual Dimming Mode: This is the manual dimming mode. Press SETUP to enter. Use the UP/DOWN keys to select as follows: P. 3 English Version | NEO- Shield IP12 PRODUCT OPERATION AND WORKING MODE INSTRUCTIONS Manual Red: 000~255 Green: 000~255 Blue: 000~255 White: 000~255 Amber: 000~255 UV: 000~255 c. Auto Mode: This is the auto-running mode. It runs based on the speed and strobe settings of the built-in programs (Program Mode:02 to Program Mode:16). Auto Yes No d. Built-in Program Mode: This mode has 16 built-in effect programs. Press SETUP to enter. Use the UP/DOWN keys to select as follows: Mode:01 (Static color effect program) Color: 01~33 Strobe: 00~99 Mode:02~16 (Built-in effect programs) Speed: 001~100 Strobe: 00~99 e. Slave Mode: This is the slave operation mode. When connected to the DMX line, it will sync with the master unit. Slave Yes No f. Settings Mode: This mode is for settings. Press SETUP to enter. Use the UP/DOWN keys to select as follows: Settings Curves Select Dimmer Speed Display PWM Frequency DMX Fail Backlight Time Lock Key Backlight Factory P. 4 English Version | NEO- Shield IP12 PRODUCT OPERATION AND WORKING MODE INSTRUCTIONS Curves Select: The product has 4 dimming curves available. Press SETUP to enter. Use the UP/DOWN keys to select as follows: Curves Select Linear Square Law Inv Square Law S-Type Dimmer Speed: Press SETUP to enter. Use the UP/DOWN keys to select as follows: Dimmer Speed Fast Smooth Display Direction Setting: Display Normal Inverted PWM Frequency Setting: PWM Frequency 12K 6K 3K 1K DMX Fail Options: Press SETUP to enter. Use the UP/DOWN keys to select as follows: DMX Fail Off (turns off the light when DMX signal fails) Hold (maintains the current state when DMX signal fails) Manual (switches to manual dimming mode when DMX signal fails) Program (switches to built-in program mode when DMX signal fails) Backlight Time Setting: Backlight Time 5s 10s 20s 30s ON Key Backlight Setting: P. 5 English Version | NEO- Shield IP12 Key Backlight On Off Standby Screen Lock: Lock On Off Restore Factory Settings: This function restores factory settings. All data will be reset. Press SETUP to enter. Use the UP/DOWN keys to select as follows: Factory Yes No g. Information Mode: This mode stores related information as follows: Information Press SETUP for 5 seconds, enter 6468 to reset Life Time. Infrared Remote Control Instructions Note: When using the remote control, aim it at the receiving part for more flexibility. ON/OFF: This button is for the on/off function. AUTO: This button is for auto mode. PRO: Press this button to enter the built-in program mode. Use "+" or "-" to select built-in programs "Program 01-16". SOUND: No function. SPEED: In built-in program mode (Program 02-16), press this button to enter speed settings. Use "+" or "-" to set the program running speed "Speed 01-100". STROBE: In built-in program mode, press this button to enter strobe settings. If in strobe state, pressing this button stops the strobe; otherwise, it starts the strobe. Use "+" or "-" to set strobe value "Strobe 00-99". DIMMING: Press this button to enter dimming mode. Press "R", "G", "B", "W", "A", or "0(UV)" and then "+" or "-" to set the brightness value "0~255". 0~9: In non-dimming mode, these keys represent static colors. When not in data setting state, pressing a number key corresponds to a static color. P. 6 English Version | NEO- Shield IP12 Colors: 0-UV, 1-Purple, 2-Magenta, 3-Orange, 4-White, 5-Pink, 6-Cyan, 7-Light Blue, 8-Yellow, 9-Warm White Static Colors: R-Red, G-Green, B-Blue, A-Amber, W-White Restore Factory Settings: First press "OFF" then sequentially press "9", "8", "7" to restore factory settings. RDM (Remote Device Management) This product supports the RDM communication protocol, which allows bidirectional communication within the standard DMX512 protocol. It enables device control, configuration, and status monitoring, such as changing the fixture's DMX address and DMX mode. Each RDM-compatible fixture can be identified by its unique UID code. Parameter ID Discovery Command DISC_UNIQUE_BRANCH * DISC_MUTE * DISC_UN_MUTE * DEVICE_INFO SOFTWARE_VERSION_ LABEL DMX_START_ADDRESS IDENTIFY_DEVICE SUPPORTED_PARAMETERS SENSOR_DEFINITION SENSOR_VALUE DMX_PERSONALITY DMX_PERSONALITY_ DESCRIPTION RESET_DEVICE FACTORY_DEFAULTS SET Command * * * * * Get Command * * * * * * * * * P. 7 English Version | NEO- Shield IP12 Proper Usage Tips Automatic Screen Lock: After 30 seconds of no key operation, the screen locks automatically, displaying the current running mode, software version, and temperature. Press and hold MODE and SETUP for 3 seconds to unlock. In unlock state, pressing MODE and SETUP simultaneously quickly locks the screen (Lock setting in Settings must be ON). Factory Reset: After powering on, while the version information is displayed, press and hold MODE and SETUP for a few seconds to restore factory settings, initializing all data. Usage According to Product Parameters: Follow the product parameters to avoid safety incidents. Environment Temperature: If the operating environment temperature is outside the allowed range, reduce the usage time at full power to prevent overheating and damage. Temperature Warning: If the display shows Temperature × or during boot-up the screen shows ×, it indicates a temperature control fault. Check the internal temperature control connections to ensure proper operation. Avoid Electric Shock: Do not disassemble the fixture while it is powered on to avoid safety incidents. P. 8 English Version | NEO- Shield IP12 P. 9 Versión Español | Tecshow NEBULA PAR 162 IIAdobe PDF Library 17.0 Adobe InDesign 19.4 (Macintosh)