LG HMC012WAE/WAC Owner's Manual
This Owner's Manual is provided and hosted by Appliance Factory Parts.
Experts in BBQ, Humidifier, & Appliance Parts
Contact: 1-800-955-7075
Shop genuine replacement parts for LG HMC012WAE/WAC
Find Your LG Air Conditioner Parts - Select From 2328 Models
Wiring Diagram
(1) 7K, 9K, 11K, 12K, 14K BTU Cooling Only
1. Indoor Unit (11K, 14K)
This section details the wiring diagram for the indoor unit of the LG HMC012WAE/WAC air conditioner, specifically for 11K and 14K BTU models. It illustrates connections for power, transformer, fan motor, compressor relay, PCB assembly, and display PCB. Key components include:
- POWER: L(1), N(2) terminals
- TRANSFORMER
- FORCED OPERATION SWITCH
- CN-TRANS, CN-FAN, CN-POWER, CN-TH, CN-UP/DOWN, CN-4WAY, CN-DISP connectors
- RY-L, RY-M, RY-H (Relays for fan speed)
- RY-COMP (Relay for compressor)
- SH-CAPA (Capacitor for fan motor)
- THERMISTOR
- STEP MOTOR
- FUSE T2A
- MAIN PCB ASM
- DISPLAY PCB ASM
- PILLAR TERMINAL (1(L), 2(N), BLACK)
The diagram shows connections to the OUTDOOR UNIT.
2. Outdoor Unit
This section provides the wiring diagram for the outdoor unit. It includes connections for:
- CAPACITOR
- COMP (Compressor) with OLP (Overload Protector)
- FAN MOTOR
- RY-COMP (Compressor Relay)
- PILLAR TERMINAL (1(L), 2(N), BLACK)
- Connections to the INDOOR UNIT
The diagram shows connections labeled with colors such as YL (Yellow), BL (Blue), GN/YL (Green/Yellow), BR (Brown), RD (Red), BK (Black), and GRAY.
Indoor Wiring Diagram (7K, 9K, 12K)
This diagram illustrates the indoor unit wiring for 7K, 9K, and 12K BTU models. It shows similar components to the 11K/14K model, including:
- POWER, TRANSFORMER, FORCED OPERATION SWITCH
- Various CN connectors (CN-TRANS, CN-FAN, CN-POWER, CN-TH, CN-UP/DOWN, CN-4WAY, CN-DISP)
- Relays (RY-L, RY-M, RY-H, RY-COMP, RY-4WAY, RY-FAN)
- SH-CAPA (Capacitor)
- THERMISTOR, STEP MOTOR
- FUSE T2A
- MAIN PCB ASM, DISPLAY PCB ASM
- PILLAR TERMINAL (1(L), 2(N), 3, 4, BLACK, GRAY)
The diagram indicates connections to the OUTDOOR UNIT.
Outdoor Wiring Diagram
This diagram shows the outdoor unit wiring, featuring:
- CAPACITOR
- COMP (Compressor) with OLP
- FAN MOTOR
- REVERSING VALVE
- PILLAR TERMINAL (1(L), 2(N), 3, 4, BLACK, GRAY)
Connections are made to the INDOOR UNIT and are color-coded (BR, BL, RD, BK, BL, BR, YL, GN/YL).