(1) Main Control Functions

1. Time Delay Safety Control

2. Airflow Direction Control

This function allows the vertical louver to swing automatically up and down or be set at a fixed position.

Procedure:

  1. Press the ON/OFF Button to operate the unit.
  2. Press the Airflow Direction Control Button to swing the vertical louver up and down automatically.
  3. Repress the Airflow Direction Control Button to set the vertical louver at a fixed position.

Airflow Direction Angles:

For <9K, 12K> Models: Diagram showing airflow direction angles for 9K and 12K models, with numbered settings for cooling and heating, indicating angle ranges.

For <18K, 24K> Models: Diagram showing airflow direction angles for 18K and 24K models, with numbered settings for cooling and heating, indicating angle ranges.

3. Cooling Operation Mode

When the Cooling (*) Mode is selected, the unit operates according to the remote controller settings. The operation diagram is shown below.

Cooling Operation Mode Diagram: Line graph illustrating intake air temperature fluctuations over time, showing compressor status (ON/OFF) and indoor fan speed (Low/Selecting) relative to setting temperatures. Time intervals like "More than 3 minutes" are indicated.

Protection of the indoor heat exchanger from frosting: Compressor and outdoor fan stop when indoor pipe temperature is below 32°F and restart when the pipe temperature is above 45°F.

Auto Operation

4. Auto Operation (Electronic Control Mode)

The operation procedure is as follows (for Cooling & Heating Models):

  1. Press Start/Stop Button
  2. Select Auto Operation Mode
  3. Check the Room temperature

Operation mode, indoor fan speed, and setting temperature are decided automatically by the unit's electronic control.

Note: If the initial mode is decided, that mode continues without room temperature changes.

Auto Operation for Cooling

Conditions:

Operation ConditionIntake-air TemperatureSetting TemperatureFan SpeedAir Direction Control
When Auto Operation initial startOver 78 °F77°FControlled by the electronic controlIn this mode, when pressing the vertical air direction control button, vertical louver swings up and down automatically.
Over 76°F~below 78°FIntake air -1°C
Over 72°F~below 76 °FIntake air -0.5°C
Over 68 °F~below 72°FIntake air temperature
below 64 °F64°F
When pressing room temperature setting button during Auto OperationOver 64 °F~below 86 °F86°FElectronic control
below 64 °F64°F

Auto Operation for Cooling Diagram: Line graph depicting intake air temperature changes, illustrating electronic control of compressor and fan speed based on various temperature conditions.

Auto Operation for Soft Dry (only Heating Model)

The setting temperature is the same as auto operation for cooling.

Intake-air temp.Setting temp.
below 68 °F68 °F
Over 68°F~below 70°FIntake air temperature +1 °F
over 86 °F86°F

Auto Operation for Heating (only Heating Model)

Vertical Louver Auto Operation

In Auto operation mode, when pressing the vertical airflow direction control button, the vertical louver moves as shown below.

Vertical Louver Auto Operation Diagram: Diagram illustrating the path of vertical louver movement through different operational modes (MODE0 to MODE9).

Operation Modes

5. Soft Dry Operation Mode

During Soft Dry Operation:

When the room temperature rises over the compressor ON temperature, the operation mode switches to Cooling operation.

When the room temperature falls between the compressor ON and OFF temperatures, the operation mode switches to Soft Dry Operation.

Soft Dry Operation Mode Diagram: Line graph showing intake air temperature changes, detailing compressor and fan speed operations during cooling, soft dry, and subsequent cooling cycles. Time intervals like "maximum 3 minutes", "10 minutes", "7 minutes" are shown.

6. Heating Operation Mode (only Heating Model)

The unit operates according to the setting conditions by the remote controller.

Heating Operation Mode Diagram: Line graph showing intake air temperature fluctuations, illustrating compressor and fan speed control during heating operations. Time intervals like "minimum 10sec.", "minimum 1 min." are indicated.

A point: While the indoor pipe temperature is higher than 95°F, indoor fan operates at low speed. When the indoor pipe temperature becomes lower than 95°F, indoor fan stops.

B point: When the indoor pipe temperature is higher than 82°F, fan operates at selected fan speed.

Hot-Start Control

The indoor fan stops until the indoor pipe temperature reaches 82°F.

During heating operation, if indoor pipe temperature falls below 78°F, the fan stops.

Hot-Start Control Diagram: Line graph showing indoor pipe temperature changes, indicating compressor and fan speed status based on temperature thresholds (82°F, 78°F). A "1 min" interval is shown.

Advanced Controls

Defrost Control

Defrost operation is controlled by timer and sensing temperature of the outdoor pipe.

Defrost Control Diagram: Line graph showing outdoor pipe temperature changes, detailing defrost control phases, compressor, fan, and valve status.

7. Cooling or Heating Mode with Sleep Mode Auto Control

When selecting the Cooling (*) or Heating () mode combined with the Sleep Mode Auto Control (), the operation diagram is as follows.

Cooling Mode with the Sleep Mode

The setting temperature automatically rises by 2°F after 30 minutes and by 4°F after 1 hour.

The operation will be stopped after 1, 2, 3, 4, 5, 6, or 7 hours.

Cooling Mode with Sleep Mode Diagram: Line graph illustrating intake air temperature changes, showing compressor and fan speed operation with automatic temperature adjustments and timed shutdowns.

Heating Mode with the Sleep Mode (only Heating Model)

The operation will be stopped after 1, 2, 3, 4, 5, 6, or 7 hours.

Heating Mode with Sleep Mode Diagram: Line graph illustrating intake air temperature changes, showing compressor and fan speed operation with timed shutdowns.

Additional Operations

8. Forced Operation

If the wireless remote controller is lost, the unit can be operated using the forced operation button.

Standard Conditions:

Heating ModelCooling Model
Room Temp ≥ 76°F70°F ≤ Room Temp < 76°FRoom temp < 70°F
Operation ModeCoolingCoolingSoft DryHeating
Indoor Fan SpeedHighHighSoft Dry RuleHigh
Setting Temp.72°F72 °F74 °F76 °F

The unit operates in low fan speed for the first 15 seconds, then switches to the proper operation mode according to intake air temperature.

Forced Operation Panel Access: Illustration showing how to open the air conditioner's front panel upwards.

Forced Operation Button: Illustration of a finger pressing the 'Forced Operation Button'. Press the Forced Operation Button once again to stop operation.

9. Crank Case Heater Coil Control (only Heating model)

When power is applied, the heater operates unconditionally.

Except for heating mode operation, the heater is always off.

During heating mode operation, the heater and compressor operate by turns (Compressor ON; Heater OFF, Compressor OFF; Heater ON).

Models: HMC018KD Room Air Conditioner, HMC018KD, Room Air Conditioner, Air Conditioner, Conditioner

File Info : application/pdf, 9 Pages, 383.99KB

PDF preview unavailable. Download the PDF instead.

121641-1

References

FPDF 1.86 AFP

Related Documents

Preview LG AG4AH12BWF01(9K) Air Conditioner Owner's Manual | Operation & Features
Comprehensive owner's manual for the LG AG4AH12BWF01(9K) air conditioner. Learn about operation modes, controls, safety features, and diagrams for your LG AC unit.
Preview LG Air Conditioner Owner's Manual
Comprehensive owner's manual for LG Floor Standing Air Conditioners, covering installation, operation, safety instructions, and maintenance. Includes detailed guides on various modes, airflow settings, timers, and troubleshooting.
Preview LG Portable Air Conditioner Owner's Manual | Operation, Safety, and Troubleshooting
Comprehensive owner's manual for LG portable air conditioners. Learn about installation, operation modes (Cool, Dry, Fan), smart functions (LG ThinQ), maintenance, and troubleshooting common issues. Includes safety warnings and guidelines.
Preview LG Window Air Conditioner Owner's Manual
This owner's manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of LG Window (Inverter) Air Conditioners. It includes safety precautions, product overview, and smart function details.
Preview LG Energy Recovery Ventilators (ERV): High Efficiency, Smart Control, and Clean Air Supply
Explore LG's range of Energy Recovery Ventilators (ERV) designed for high efficiency, smart control, and improved indoor air quality. Featuring advanced heat exchangers, CO2 monitoring, UVnano technology, and easy maintenance for residential and commercial applications.
Preview LG LW1517IVSM Air Conditioner Owner's Manual
Comprehensive owner's manual for the LG LW1517IVSM Window Air Conditioner, covering safety instructions, product overview, installation, operation, maintenance, troubleshooting, and warranty information.
Preview LG Wall Mounted Air Conditioner Owner's Manual
This comprehensive owner's manual provides essential information for the safe and effective operation of your LG Wall Mounted Air Conditioner, model type K*SAL**1A. It is designed to help users understand all aspects of their appliance, from initial setup and daily use to maintenance and troubleshooting.
Preview LG Air Conditioner Owner's Manual: Operation, Safety, and Maintenance Guide
Comprehensive owner's manual for LG Wall Mounted Air Conditioners, covering essential safety instructions, detailed operation guides, smart features like LG ThinQ, maintenance procedures, and troubleshooting tips.