Hoymiles HMS-1000-2T-NA Series Quick Installation Guide

*Applicable to HMS-700/800/900/1000-2T-NA microinverters

1. Accessories

ItemDescription
AAC Trunk Cable, 12/10 AWG Cable
BM8 x 25 screws (Prepared by the installer)
CGrounding Electrode
DAC Trunk Connector
EAC Trunk Port Cap
FAC Trunk Port Disconnect Tool
GAC Trunk End Cap
HAC Trunk Connector Unlock Tool

Diagram showing Hoymiles microinverter accessories labeled A through H.

*Note: All accessories above are not included in the package and should be purchased separately.

2. Installation Steps

The order of Step 1 and Step 2 can be reversed according to your planned needs.

Step 1. Plan and Install the Microinverter

A) Mark the position of each microinverter on the rail according to the PV module layout.

B) Fix the screws on the rail.

C) Hang the microinverter on the screws, and tighten the screws. The silver cover side of the microinverter should be facing the panel.

Diagram illustrating microinverter installation on a rail, with a mounting torque of 9 N•m indicated for the screws.

Notes:

Step 2. Plan and build the AC Bus Cable

AC Trunk Cable is used to connect the microinverter to distribution box.

A) Select the appropriate AC Trunk Cable according to the spacing between microinverters. The connector spacing of the AC Trunk Cable should be close to spacing between microinverters to ensure that they are well-matched. (Hoymiles provides AC Trunk Cable with different AC Trunk Connector spacing.)

B) Determine how many microinverters you plan to install on each AC branch and prepare AC Trunk Connectors accordingly.

C) Take out segments of AC Trunk Cable as you need to make AC branch.

1) Disassemble the AC Trunk Connector and remove the cable.

Use the AC Trunk Connector Unlock Tool ? to unlock the connector upper cover.

Loosen the three screws with screwdriver ?. Untighten the cap and remove the cable.

Diagram showing the disassembly of an AC Trunk Connector, illustrating the use of an unlock tool and screwdriver.

2) Install the AC Trunk End Cap at one side of AC Trunk Cable (the end of AC Trunk Cable)

Insert the AC Trunk End cap and screw the cap back to port, and then tighten the cap.

Plug the upper cover back to the Trunk connector. [click]

Diagram showing the installation of an AC Trunk End Cap onto the AC Trunk Cable, with a torque specification of 4.0±0.5 N•m indicated.

3) Install AC end cable on the other side of AC Trunk Cable (connected to the distribution box)

Unlock the port upper cover, loosen the screws with screwdriver ? and remove the extra cable. (Skip this step if there is no cable at this side.)

Prepare a segment of AC cable with suitable length to connect to the distribution box, with stripping requirements fulfilled.

Insert the cable into the cap in a way that the L, N and PE lines are in corresponding slots.

Diagram showing AC cable connection to the AC Trunk Connector, indicating L (Line), N (Neutral), and PE (Protective Earth) lines, with stripping dimensions of 8±1mm and 40±5mm.

Tighten the screws and tighten the cap back to the port.

Diagram showing the tightened AC Trunk Connector cap with torque specifications of 4.0±0.5 N•m for the cap and 0.4±0.1 N•m for the locking screw.

Plug the upper cover back to the Trunk connector. [click]

Notes:

D) Repeat the above steps, lay out the cable on the rail as appropriate so that the microinverters can be connected to the Trunk connectors.

E) Attach the AC Trunk Cable to the mounting rail and fix the cable with tie wraps.

Step 3. Complete the AC Connection

A) Push the AC Sub Connector from microinverter to the AC Trunk Connector until it clicks [click].

B) Connect the AC end cable to the distribution box, and wire it to the local grid network.

C) Please plug the AC Trunk Port Cap in any vacant AC Trunk Port to make it water and dust-proof. [click]

Diagram showing the AC Sub Connector being plugged into the AC Trunk Connector, and another showing the AC Trunk Port Cap being inserted.

Notes:

Step 4. Create an Installation Map

A) Peel the removable serial number label from each microinverter.

B) Affix the serial number label to the respective location on the installation map (please refer to the User Manual).

Diagram of the Hoymiles Microinverter Installation Map, with fields for system details and a grid for placing serial number labels.

Step 5. Connect PV Modules

A) Mount the PV modules above the microinverter.

B) Connect the PV modules' DC cables to the DC input side of the microinverter.

Diagram illustrating PV modules mounted above the microinverter, with DC cables connecting to the microinverter.

Step 6. Energize the System

A) Turn on the AC breaker for the branch circuit.

B) Turn on the main AC breaker for the house. Your system will start to generate power in about two minutes.

Step 7. Set up Monitoring System

Please refer to the "DTU User Manual", "DTU Quick Installation Guide", and "Quick Installation Guide for S-Miles Cloud" to install the DTU and set up monitoring system.

Product information is subject to change without notice. (Please download reference manuals at www.hoymiles.com).

Region: North America AP040440 REV1.2 © 2022 Hoymiles Power Electronics Inc.

Models: HMS-1000-2T-NA Series Microinverter, HMS-1000-2T-NA Series, Microinverter

File Info : application/pdf, 2 Pages, 8.77MB

PDF preview unavailable. Download the PDF instead.

Quick Installation Guide HMS-1000-2T-NA Series NA EN REV1.2

References

Adobe PDF library 15.00 Adobe Illustrator(R) 24.0

Related Documents

Preview Hoymiles HMS Series Microinverter Datasheet - HMS-700-2T-NA to HMS-1000-2T-NA
Datasheet for Hoymiles HMS series 2-in-1 microinverters (HMS-700-2T-NA, HMS-800-2T-NA, HMS-900-2T-NA, HMS-1000-2T-NA), detailing technical specifications, features, and compliance for high-powered solar panel installations.
Preview Hoymiles Single-Phase Microinverter HMS-800/900/1000-2T User Manual
Comprehensive user manual for Hoymiles Single-Phase Microinverters, models HMS-800-2T, HMS-900-2T, and HMS-1000-2T. Covers installation, operation, troubleshooting, and technical specifications for efficient solar energy conversion.
Preview Hoymiles HMS-800-2T/900-2T/1000-2T Single-Phase Microinverter User Manual
Comprehensive user manual for Hoymiles HMS-800-2T, HMS-900-2T, and HMS-1000-2T single-phase microinverters. Covers installation, safety, troubleshooting, technical data, and wiring diagrams for solar PV systems.
Preview Hoymiles HMS-1000-2T Series Quick Installation Guide
A concise guide for installing Hoymiles HMS-1000-2T series microinverters, detailing accessory lists, step-by-step installation procedures for microinverters and AC bus cables, AC connection, system energization, and monitoring setup.
Preview Hoymiles HMS-1000W-2T Bedienungsanleitung: Einphasiger Mikro-Wechselrichter
Umfassende Bedienungsanleitung für den Hoymiles einphasigen Mikro-Wechselrichter der HMS-1000W Serie. Enthält Installationsanweisungen, Sicherheitshinweise, technische Daten und Fehlerbehebung für Modelle wie HMS-600W-2T, HMS-700W-2T, HMS-800W-2T, HMS-900W-2T und HMS-1000W-2T.
Preview Hoymiles HMS-2000C-4T-NA Series Quick Installation Guide
A quick installation guide for the Hoymiles HMS-2000C-4T-NA Series microinverters, detailing accessories, installation steps, AC connection, and system setup.
Preview Hoymiles HMS-1600/1800/2000-4T-NA Single-phase Microinverter User Manual
Comprehensive user manual for Hoymiles HMS-1600-4T-NA, HMS-1800-4T-NA, and HMS-2000-4T-NA single-phase microinverters. Covers installation, operation, troubleshooting, and technical specifications for efficient solar energy conversion.
Preview Hoymiles Single-Phase Microinverter User Manual
Comprehensive user manual for Hoymiles single-phase microinverters, including models HMS-1600-4T-NA, HMS-1800-4T-NA, and HMS-2000-4T-NA. Covers installation, operation, troubleshooting, and technical specifications.