Hoymiles Microinverter Datasheet

Open Energy For All

Models: HMS-700-2T-NA, HMS-800-2T-NA, HMS-900-2T-NA, HMS-1000-2T-NA

Description

Hoymiles' new microinverter HMS-1000 series is designed for high-powered solar panels, positioning it among the top 2-in-1 microinverters. Each unit supports up to two panels, utilizing independent Maximum Power Point Tracking (MPPT) and monitoring to optimize power production for the installation. With a maximum DC voltage of 65 volts, Hoymiles microinverters function as PV Rapid Shutdown Equipment, complying with NEC-2017, NEC-2020 Article 690.12, and CEC-2021 Section 64-218. The integrated Sub-1G wireless solution ensures stable communication with the Hoymiles gateway DTU.

Features

Technical Specifications

HMS-700-2T-NA HMS-800-2T-NA HMS-900-2T-NA HMS-1000-2T-NA
Input Data (DC)
Commonly used module power (W) 280 to 470+ 320 to 540+ 360 to 600+ 400 to 670+
Maximum input voltage (V) 60 65 65 65
MPPT voltage range (V) 16-60
Start-up voltage (V) 22
Maximum input current (A) 2 x 11.5 2 x 12.5 2 x 13.3 2 x 14
Maximum input short circuit current (A) 2 x 16 2 x 20 2 x 20 2 x 20
Number of MPPTs 2
Number of inputs per MPPT 1
Output Data (AC)
Peak output power (VA) 700 800 900 1000
Maximum continuous output power (VA) 638 720 820 958
Maximum continuous output current (A) 2.66 3.07
3.00
3.46
3.42
3.94
3.99
4.61
Nominal output voltage/range (V)¹ 240/211-264
208/183-228
Nominal frequency/range (Hz)¹ 60/55-65
Adjustable power factor (@nominal power) > 0.99 default
0.8 leading ... 0.8 lagging
Total harmonic distortion (@nominal power) < 3%
Maximum units per 10 AWG branch² 9 7 8 6 7 6 6 5
Maximum units per 12 AWG branch² 6 5 5 4 4 4 4 3
Efficiency
CEC peak efficiency 96.70% 96.70% 96.50% 96.50%
Nominal MPPT efficiency 99.8%
Night power consumption (mW) < 50
Mechanical Data
Ambient temperature range (°F) -40 to +149 (-40°C to +65°C)
Dimensions (W × H × D [inches]) 10.28 × 7.09 × 1.22 (261 × 180 × 31 mm)
Weight (lbs) 6.83 (3.1 kg)
Enclosure rating NEMA 6 (Outdoor-IP67)
Cooling Natural convection-No fans
Features
Communication Sub-1G
Type of isolation Galvanically Isolated HF Transformer
Monitoring Hoymiles S-Miles Cloud (Hoymiles Monitoring Platform)
Compliance UL 1741, IEEE 1547, UL 1741 SA, UL 1741 SB (Pending), CA Rule21⁴, CSA C22.2 No. 107.1-16, FCC 15B, FCC 15C
PV Rapid Shutdown Conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems.

* : Nominal voltage/frequency range can vary depending on local requirements.
** : Refer to local requirements for exact number of microinverters per branch.
***: The HMS-1000-2T-NA microinverter complies with both CA Rule 21 (240 Vac) and CA Rule 21 (208 Vac).

PDF preview unavailable. Download the PDF instead.

Datasheet HMS-7008009001000-2T NA EN V202403-1 Adobe PDF Library 17.0 Adobe InDesign 18.3 (Windows)

Related Documents

Preview Hoymiles HMS-1000-2T-NA Series Quick Installation Guide
Concise installation guide for Hoymiles HMS-1000-2T-NA series microinverters, detailing accessories, AC bus cable setup, and system connection steps for solar power systems.
Preview Hoymiles HMS-800-2T/900-2T/1000-2T Single-Phase Microinverter User Manual
Comprehensive user manual for Hoymiles HMS-800-2T, HMS-900-2T, and HMS-1000-2T single-phase microinverters. Covers installation, safety, troubleshooting, technical data, and wiring diagrams for solar PV systems.
Preview Hoymiles Single-Phase Microinverter HMS-800/900/1000-2T User Manual
Comprehensive user manual for Hoymiles Single-Phase Microinverters, models HMS-800-2T, HMS-900-2T, and HMS-1000-2T. Covers installation, operation, troubleshooting, and technical specifications for efficient solar energy conversion.
Preview Hoymiles HMS-1000-2T Series Quick Installation Guide
A concise guide for installing Hoymiles HMS-1000-2T series microinverters, detailing accessory lists, step-by-step installation procedures for microinverters and AC bus cables, AC connection, system energization, and monitoring setup.
Preview Hoymiles HMS-1000W-2T Bedienungsanleitung: Einphasiger Mikro-Wechselrichter
Umfassende Bedienungsanleitung für den Hoymiles einphasigen Mikro-Wechselrichter der HMS-1000W Serie. Enthält Installationsanweisungen, Sicherheitshinweise, technische Daten und Fehlerbehebung für Modelle wie HMS-600W-2T, HMS-700W-2T, HMS-800W-2T, HMS-900W-2T und HMS-1000W-2T.
Preview Hoymiles HMS-1600/1800/2000-4T-NA Single-phase Microinverter User Manual
Comprehensive user manual for Hoymiles HMS-1600-4T-NA, HMS-1800-4T-NA, and HMS-2000-4T-NA single-phase microinverters. Covers installation, operation, troubleshooting, and technical specifications for efficient solar energy conversion.
Preview Hoymiles HMS-2000C-4T-NA Series Quick Installation Guide
A quick installation guide for the Hoymiles HMS-2000C-4T-NA Series microinverters, detailing accessories, installation steps, AC connection, and system setup.
Preview Hoymiles Single-Phase Microinverter User Manual
Comprehensive user manual for Hoymiles single-phase microinverters, including models HMS-1600-4T-NA, HMS-1800-4T-NA, and HMS-2000-4T-NA. Covers installation, operation, troubleshooting, and technical specifications.