Description
Hoymiles' new microinverter HMS-1000 series is designed for high-powered solar panels, positioning it among the top 2-in-1 microinverters. Each unit supports up to two panels, utilizing independent Maximum Power Point Tracking (MPPT) and monitoring to optimize power production for the installation. With a maximum DC voltage of 65 volts, Hoymiles microinverters function as PV Rapid Shutdown Equipment, complying with NEC-2017, NEC-2020 Article 690.12, and CEC-2021 Section 64-218. The integrated Sub-1G wireless solution ensures stable communication with the Hoymiles gateway DTU.
Features
- 01 High-powered microinverter for 2-in-1 series with superior performance
- 02 Safer for rooftop solar stations with PV rapid shutdown compliance
- 03 With Reactive Power Control, compliant with UL 1741, IEEE 1547, UL 1741 SA, CA Rule21, etc.
- 04 Independent MPPT and monitoring ensure greater energy harvest and easier maintenance
- 05 2-in-1 design enables faster installation
- 06 Sub-1G wireless solution allows stable communication in commercial and industrial settings
Technical Specifications
HMS-700-2T-NA | HMS-800-2T-NA | HMS-900-2T-NA | HMS-1000-2T-NA | |||||
---|---|---|---|---|---|---|---|---|
Input Data (DC) | ||||||||
Commonly used module power (W) | 280 to 470+ | 320 to 540+ | 360 to 600+ | 400 to 670+ | ||||
Maximum input voltage (V) | 60 | 65 | 65 | 65 | ||||
MPPT voltage range (V) | 16-60 | |||||||
Start-up voltage (V) | 22 | |||||||
Maximum input current (A) | 2 x 11.5 | 2 x 12.5 | 2 x 13.3 | 2 x 14 | ||||
Maximum input short circuit current (A) | 2 x 16 | 2 x 20 | 2 x 20 | 2 x 20 | ||||
Number of MPPTs | 2 | |||||||
Number of inputs per MPPT | 1 | |||||||
Output Data (AC) | ||||||||
Peak output power (VA) | 700 | 800 | 900 | 1000 | ||||
Maximum continuous output power (VA) | 638 | 720 | 820 | 958 | ||||
Maximum continuous output current (A) | 2.66 | 3.07 3.00 |
3.46 3.42 |
3.94 3.99 4.61 |
||||
Nominal output voltage/range (V)¹ | 240/211-264 208/183-228 |
|||||||
Nominal frequency/range (Hz)¹ | 60/55-65 | |||||||
Adjustable power factor (@nominal power) | > 0.99 default 0.8 leading ... 0.8 lagging |
|||||||
Total harmonic distortion (@nominal power) | < 3% | |||||||
Maximum units per 10 AWG branch² | 9 | 7 | 8 | 6 | 7 | 6 | 6 | 5 |
Maximum units per 12 AWG branch² | 6 | 5 | 5 | 4 | 4 | 4 | 4 | 3 |
Efficiency | ||||||||
CEC peak efficiency | 96.70% | 96.70% | 96.50% | 96.50% | ||||
Nominal MPPT efficiency | 99.8% | |||||||
Night power consumption (mW) | < 50 | |||||||
Mechanical Data | ||||||||
Ambient temperature range (°F) | -40 to +149 (-40°C to +65°C) | |||||||
Dimensions (W × H × D [inches]) | 10.28 × 7.09 × 1.22 (261 × 180 × 31 mm) | |||||||
Weight (lbs) | 6.83 (3.1 kg) | |||||||
Enclosure rating | NEMA 6 (Outdoor-IP67) | |||||||
Cooling | Natural convection-No fans | |||||||
Features | ||||||||
Communication | Sub-1G | |||||||
Type of isolation | Galvanically Isolated HF Transformer | |||||||
Monitoring | Hoymiles S-Miles Cloud (Hoymiles Monitoring Platform) | |||||||
Compliance | UL 1741, IEEE 1547, UL 1741 SA, UL 1741 SB (Pending), CA Rule21⁴, CSA C22.2 No. 107.1-16, FCC 15B, FCC 15C | |||||||
PV Rapid Shutdown | Conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems. |
* : Nominal voltage/frequency range can vary depending on local requirements.
** : Refer to local requirements for exact number of microinverters per branch.
***: The HMS-1000-2T-NA microinverter complies with both CA Rule 21 (240 Vac) and CA Rule 21 (208 Vac).