Innovair SLIM4 Heat Pump Series Submittal Data Sheets

Model: SOV18H2BA / SWV18BDA (18K)

Series: SLIM4 Heat Pump Series

Indoor Specifications

ESP (inWG)0~0.8
Indoor Air Flow (Turbo/H/M/L/Si) (CFM)618.0 / 576.8 / 529.7 / 488.5 / /
Indoor Noise Level (Turbo/H/M/L/Si) (dBA)48.0 / 47 / 45 / 39 / N/A
Dimension (W×D×H)20.28 x 15.71 x 36.54 in (515 x 399 x 928 mm)
Package (W×D×H)22.83 x 19.49 x 42.91 in (580 x 495 x 1090 mm)
Net/Gross Weight111.33 / 91.49 lbs (50.5 / 41.5 kg)

Outdoor Specifications

Compressor TypeROTARY
Compressor ModelKSN140D58UFZ
RefrigerantR454B
Refrigerant Oil Charge (mL)440
Refrigerant OilVG74
Outdoor Air Flow (Max) (CFM)1450.9
Outdoor Noise Level (dBA)55.5
Dimension (W×D×H)31.69 x 12.99 x 21.81 in (805 x 330 x 554 mm)
Package (W×D×H)36.02 x 14.57 x 24.21 in (915 x 370 x 615 mm)
Net/Gross Weight77.16 / 83.77 lbs (35 / 38 kg)

Efficiency

CoolingHeating
SEER218.5HSPF2-4: 9.4
EER211.5COP: 3.55

Performance of Cooling

Rated Capacity (Btu/hr)18000
Min/Max Capacity (Btu/hr)5900~20600
Moisture Removal (L/h)1.87
Standard Operating Range (°F/°C)-25~50 (-25~50)
Rated Cooling ConditionsIndoor: 80°F DB/67°F WB, Outdoor: 95°F DB/75°F WB

Performance of Heating

1. @ 47°F Rated (Btu/hr)18000
2. @ 47°F Min/Max Capacity (Btu/hr)3900~19600
3. @ 17°F Rated (Btu/hr)12600
4. @ 5°F Rated: Capacity / COP11400 / 2.1
5. @ 5°F Max: Capacity (Btu/hr)11400
Standard Operating Range (°F/°C)-25~24 (-25~24)
Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 47°F DB/43°F WB
2. Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 17°F DB/15°F WB
3. Heating Conditions, Compressor Operating at Max. FrequencyIndoor: 70°F DB/60°F WB, Outdoor: 5°F DB/5°F WB

Electrical

Indoor Power Supply115/208/230V, 60Hz, 1Ph
Indoor MCA (115V/(208/230V))4A
Indoor MOP15A
Outdoor Power Supply208/230V, 60Hz, 1Ph
Outdoor MCA16A
Outdoor MOP20A
Communication WiringAWG 20-2
Compressor RLA10A
Outdoor Fan Motor RLA0.8A
Outdoor Fan Motor W/
Indoor Fan Motor RLA3A
Indoor Fan Motor W250W
System Power Input @ Cooling (W)1565 (360~1820)
System Power Input @ Heating (W)1485 (275~1610)
MCA: Min. circuit amps (A)
MOCP: Max. over current protection (A)
RLA: Rated load amps (A)
W: Fan motor rated output (W)

Piping

Throttle type (Indoor)EXV
Throttle type (Outdoor)EXV
Liquid Size9.52mm (3/8in)
Gas Size19mm (3/4in)
Max. Piping Length (ft/m)98.40 (30)
Max. Height Difference (ft/m)65.60 (20)
Max. Pre-charged Length (ft/m)24.6 (7.5)
Refrigerant Pre-charged Amount (oz/kg)51.15 (1.45)
Additional Charge of Refrigerant ((oz/ft)/(g/m))0.7 (65)
Connection MethodFlared*

Indoor Unit Dimensions

Dimensions for 18K/24K models:

Dimension LabelDimension (inch)Dimension (mm)
A - Model Height36.5928
B - Model Width20.3515
C - Supply Air Opening Width17.4442
D - Return Air Opening Width19.4493.8
E - Model Depth15.7399
F - Supply Air Opening Depth10.4265.2
G - Return Air Opening Depth10.3261
H - Supply Air Opening Clearance1.129.1
I - Return Air Opening Side Clearance0.4210.6
J - Return Air Opening Front Clearance0.4712

Outdoor Unit Dimensions

Key dimensions for the outdoor unit (refer to diagrams for specific views and labels):

  • Width (W): 31.69 in (805 mm)
  • Depth (D): 12.99 in (330 mm)
  • Height (H): 21.81 in (554 mm)
  • Package Width: 36.02 in (915 mm)
  • Package Depth: 14.57 in (370 mm)
  • Package Height: 24.21 in (615 mm)

Installation Instructions for Outdoor Unit

Clearance Requirements:

  • 20 inches (500mm) or more on sides, front, and rear when any 2 sides are clear.
  • 20 inches (500mm) or more when front and sides are clear.
  • 4 inches (100mm) or more on all sides.
  • 14 inches (350mm) or more on the front.

The unit meets all spatial requirements shown in Installation Clearance Requirements.

Fan Performance for Indoor Unit (18K)

This section presents a chart illustrating the relationship between external static pressure (in.w.c.) and air flow rate (CFM) for the 18K indoor unit. The chart displays distinct lines for different fan speeds: Turbo, M (Medium), H (High), and L (Low).

Model: SOV24H2BA / SWV24BDA (24K)

Series: SLIM4 Heat Pump Series

Indoor Specifications

ESP (inWG)0~0.8
Indoor Air Flow (Turbo/H/M/L/Si) (CFM)824.0 / 759.3 / 694.5 / 629.8 / /
Indoor Noise Level (Turbo/H/M/L/Si) (dBA)53.0 / 51 / 48 / 37.5 / N/A
Dimension (W×D×H)20.28 x 15.71 x 36.54 in (515 x 399 x 928 mm)
Package (W×D×H)22.83 x 19.49 x 42.91 in (580 x 495 x 1090 mm)
Net/Gross Weight91.49 / 111.33 lbs (41.5 / 50.5 kg)

Outdoor Specifications

Compressor TypeROTARY
Compressor ModelKTM240D46UKT2
RefrigerantR454B
Refrigerant Oil Charge (mL)620
Refrigerant OilVG74
Outdoor Air Flow (Max) (CFM)1765.8
Outdoor Noise Level (dBA)59
Dimension (W×D×H)35.04 x 13.46 x 26.50 in (890 x 342 x 673 mm)
Package (W×D×H)39.17 x 15.67 x 29.13 in (995 x 398 x 740 mm)
Net/Gross Weight101.41 / 109.13 lbs (46 / 49.5 kg)

Efficiency

CoolingHeating
SEER217.4HSPF2-4: 10.4
EER210.8COP: 3.80

Performance of Cooling

Rated Capacity (Btu/hr)24000
Min/Max Capacity (Btu/hr)10100~27500
Moisture Removal (L/h)2.5
Standard Operating Range (°F/°C)-25~50 (-25~50)
Rated Cooling ConditionsIndoor: 80°F DB/67°F WB, Outdoor: 95°F DB/75°F WB

Performance of Heating

1. @ 47°F Rated (Btu/hr)25000
2. @ 47°F Min/Max Capacity (Btu/hr)7000~32200
3. @ 17°F Rated (Btu/hr)20800
4. @ 5°F Rated: Capacity / COP19400 / 1.96
5. @ 5°F Max: Capacity (Btu/hr)19400
Standard Operating Range (°F/°C)-25~24 (-25~24)
Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 47°F DB/43°F WB
2. Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 17°F DB/15°F WB
3. Heating Conditions, Compressor Operating at Max. FrequencyIndoor: 70°F DB/60°F WB, Outdoor: 5°F DB/5°F WB

Electrical

Indoor Power Supply115/208/230V, 60Hz, 1Ph
Indoor MCA (115V/(208/230V))4A
Indoor MOP15A
Outdoor Power Supply208/230V, 60Hz, 1Ph
Outdoor MCA19A
Outdoor MOP20A
Communication WiringAWG 20-2
Compressor RLA14A
Outdoor Fan Motor RLA1A
Outdoor Fan Motor W/
Indoor Fan Motor RLA3A
Indoor Fan Motor W250W
System Power Input @ Cooling (W)2222 (830 ~ 2850)
System Power Input @ Heating (W)1980 (455 ~ 2590)
MCA: Min. circuit amps (A)
MOCP: Max. over current protection (A)
RLA: Rated load amps (A)
W: Fan motor rated output (W)

Piping

Throttle type (Indoor)EXV
Throttle type (Outdoor)EXV
Liquid Size9.52mm (3/8in)
Gas Size19mm (3/4in)
Max. Piping Length (ft/m)164 (50)
Max. Height Difference (ft/m)82 (25)
Max. Pre-charged Length (ft/m)24.6 (7.5)
Refrigerant Pre-charged Amount (oz/kg)74.08 (2.1)
Additional Charge of Refrigerant ((oz/ft)/(g/m))0.7 (65)
Connection MethodFlared

Indoor Unit Dimensions

Dimensions for 18K/24K models:

Dimension LabelDimension (inch)Dimension (mm)
A - Model Height36.5928
B - Model Width20.3515
C - Supply Air Opening Width17.4442
D - Return Air Opening Width19.4493.8
E - Model Depth15.7399
F - Supply Air Opening Depth10.4265.2
G - Return Air Opening Depth10.3261
H - Supply Air Opening Clearance1.129.1
I - Return Air Opening Side Clearance0.4210.6
J - Return Air Opening Front Clearance0.4712

Outdoor Unit Dimensions

Key dimensions for the outdoor unit (refer to diagrams for specific views and labels):

  • Width (W): 35.04 in (890 mm)
  • Depth (D): 13.46 in (342 mm)
  • Height (H): 26.50 in (673 mm)
  • Package Width: 39.17 in (995 mm)
  • Package Depth: 15.67 in (398 mm)
  • Package Height: 29.13 in (740 mm)

Installation Instructions for Outdoor Unit

Clearance Requirements:

  • 20 inches (500mm) or more on sides, front, and rear when any 2 sides are clear.
  • 20 inches (500mm) or more when front and sides are clear.
  • 4 inches (100mm) or more on all sides.
  • 14 inches (350mm) or more on the front.

The unit meets all spatial requirements shown in Installation Clearance Requirements.

Fan Performance for Indoor Unit (24K)

This section presents a chart illustrating the relationship between external static pressure (in.w.c.) and air flow rate (CFM) for the 24K indoor unit. The chart displays distinct lines for different fan speeds: Turbo, H (High), M (Medium), and L (Low).

Model: SOV30H2BA / SWV30BDA (30K)

Series: SLIM4 Heat Pump Series

Indoor Specifications

ESP (inWG)0~0.8
Indoor Air Flow (Turbo/H/M/L/Si) (CFM)988.8 / 894.7 / 806.4 / 712.2 / N/A
Indoor Noise Level (Turbo/H/M/L/Si) (dBA)50.5 / 50 / 48 / 36 / N/A
Dimension (W×D×H)22.01 x 19.02 x 40.04 in (559 x 483 x 1017 mm)
Package (W×D×H)24.61 x 22.83 x 46.97 in (625 x 580 x 1193 mm)
Net/Gross Weight110.23 / 131.39 lbs (50 / 59.6 kg)

Outdoor Specifications

Compressor TypeROTARY
Compressor ModelKTF250D22UMT
RefrigerantR454B
Refrigerant Oil Charge (mL)670
Refrigerant OilVG74
Outdoor Air Flow (Max) (CFM)3001.9
Outdoor Noise Level (dBA)61
Dimension (W×D×H)37.24 x 16.14 x 31.89 in (946 x 410 x 810 mm)
Package (W×D×H)42.91 x 19.69 x 34.84 in (1090 x 500 x 885 mm)
Net/Gross Weight141.76 / 152.34 lbs (64.3 / 69.1 kg)

Efficiency

CoolingHeating
SEER218.6HSPF2-4: 8.7
EER211COP: 3.5

Performance of Cooling

Rated Capacity (Btu/hr)30000
Min/Max Capacity (Btu/hr)10100~34400
Moisture Removal (L/h)2.99
Standard Operating Range (°F/°C)-25~50 (-25~50)
Rated Cooling ConditionsIndoor: 80°F DB/67°F WB, Outdoor: 95°F DB/75°F WB

Performance of Heating

1. @ 47°F Rated (Btu/hr)31000
2. @ 47°F Min/Max Capacity (Btu/hr)6500~31900
3. @ 17°F Rated (Btu/hr)18200
4. @ 5°F Rated: Capacity / COP18700 / 1.99
5. @ 5°F Max: Capacity (Btu/hr)18700
Standard Operating Range (°F/°C)-25~24 (-25~24)
Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 47°F DB/43°F WB
2. Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 17°F DB/15°F WB
3. Heating Conditions, Compressor Operating at Max. FrequencyIndoor: 70°F DB/60°F WB, Outdoor: 5°F DB/5°F WB

Electrical

Indoor Power Supply115/208/230V, 60Hz, 1Ph
Indoor MCA (115V/(208/230V))6A
Indoor MOP15A
Outdoor Power Supply208/230V, 60Hz, 1Ph
Outdoor MCA22.5A
Outdoor MOP25A
Communication WiringAWG 20-2
Compressor RLA17A
Outdoor Fan Motor RLA1.1A
Outdoor Fan Motor W/
Indoor Fan Motor RLA4.5A
Indoor Fan Motor W375W
System Power Input @ Cooling (W)2727 (670 ~ 3130)
System Power Input @ Heating (W)2596 (400 ~ 2550)
MCA: Min. circuit amps (A)
MOCP: Max. over current protection (A)
RLA: Rated load amps (A)
W: Fan motor rated output (W)

Piping

Throttle type (Indoor)EXV
Throttle type (Outdoor)EXV
Liquid Size9.52mm (3/8in)
Gas Size19mm (3/4in)
Max. Piping Length (ft/m)164 (50)
Max. Height Difference (ft/m)82 (25)
Max. Pre-charged Length (ft/m)24.6 (7.5)
Refrigerant Pre-charged Amount (oz/kg)91.71 (2.6)
Additional Charge of Refrigerant ((oz/ft)/(g/m))0.7 (65)
Connection MethodFlared

Indoor Unit Dimensions

Dimensions for 30K/36K models:

Dimension LabelDimension (inch)Dimension (mm)
A - Model Height491017
B - Model Width21559
C - Supply Air Opening Width18.8478.6
D - Return Air Opening Width21.2537.8
E - Model Depth21483
F - Supply Air Opening Depth9.3235.4
G - Return Air Opening Depth13.1332.5
H - Supply Air Opening Clearance1.641
I - Return Air Opening Side Clearance0.4210.6
J - Return Air Opening Front Clearance0.6316

Outdoor Unit Dimensions

Key dimensions for the outdoor unit (refer to diagrams for specific views and labels):

  • Width (W): 37.24 in (946 mm)
  • Depth (D): 16.14 in (410 mm)
  • Height (H): 31.89 in (810 mm)
  • Package Width: 42.91 in (1090 mm)
  • Package Depth: 19.69 in (500 mm)
  • Package Height: 34.84 in (885 mm)

Installation Instructions for Outdoor Unit

Clearance Requirements:

  • 20 inches (500mm) or more on sides, front, and rear when any 2 sides are clear.
  • 20 inches (500mm) or more when front and sides are clear.
  • 4 inches (100mm) or more on all sides.
  • 14 inches (350mm) or more on the front.

The unit meets all spatial requirements shown in Installation Clearance Requirements.

Fan Performance for Indoor Unit (30K)

This section presents a chart illustrating the relationship between external static pressure (in.w.c.) and air flow rate (CFM) for the 30K indoor unit. The chart displays distinct lines for different fan speeds: Turbo, H (High), M (Medium), and L (Low).

Model: SOV36H2BA / SWV36BDA (36K)

Series: SLIM4 Heat Pump Series

Indoor Specifications

ESP (inWG)0~0.8
Indoor Air Flow (Turbo/H/M/L/Si) (CFM)1189.0 / 1083.0 / 971.2 / 865.2 / /
Indoor Noise Level (Turbo/H/M/L/Si) (dBA)50.5 / 48 / 36.5 / N/A
Dimension (W×D×H)22.01 x 19.02 x 40.04 in (559 x 483 x 1017 mm)
Package (W×D×H)24.61 x 22.83 x 46.97 in (625 x 580 x 1193 mm)
Net/Gross Weight109.57 / 130.73 lbs (49.7 / 59.3 kg)

Outdoor Specifications

Compressor TypeROTARY
Compressor ModelKTF310D43UMT
RefrigerantR454B
Refrigerant Oil Charge (mL)1000
Refrigerant OilVG74
Outdoor Air Flow (Max) (CFM)2413.3
Outdoor Noise Level (dBA)62
Dimension (W×D×H)37.24 x 16.14 x 31.89 in (946 x 410 x 810 mm)
Package (W×D×H)42.91 x 19.69 x 34.84 in (1090 x 500 x 885 mm)
Net/Gross Weight153.22 / 163.58 lbs (69.5 / 74.2 kg)

Efficiency

CoolingHeating
SEER216.7HSPF2-4: 9.3
EER210.2COP: 3.3

Performance of Cooling

Rated Capacity (Btu/hr)36000
Min/Max Capacity (Btu/hr)11800~39000
Moisture Removal (L/h)3.37
Standard Operating Range (°F/°C)-25~50 (-25~50)
Rated Cooling ConditionsIndoor: 80°F DB/67°F WB, Outdoor: 95°F DB/75°F WB

Performance of Heating

1. @ 47°F Rated (Btu/hr)37000
2. @ 47°F Min/Max Capacity (Btu/hr)6900~41000
3. @ 17°F Rated (Btu/hr)24800
4. @ 5°F Rated: Capacity / COP29200 / 1.99
5. @ 5°F Max: Capacity (Btu/hr)29200
Standard Operating Range (°F/°C)-25~24 (-25~24)
Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 47°F DB/43°F WB
2. Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 17°F DB/15°F WB
3. Heating Conditions, Compressor Operating at Max. FrequencyIndoor: 70°F DB/60°F WB, Outdoor: 5°F DB/5°F WB

Electrical

Indoor Power Supply115/208/230V, 60Hz, 1Ph
Indoor MCA (115V/(208/230V))6.5A
Indoor MOP15A
Outdoor Power Supply208/230V, 60Hz, 1Ph
Outdoor MCA24A
Outdoor MOP30A
Communication WiringAWG 20-2
Compressor RLA17.5A
Outdoor Fan Motor RLA1.5A
Outdoor Fan Motor W/
Indoor Fan Motor RLA5A
Indoor Fan Motor W375W
System Power Input @ Cooling (W)3529 (760 ~ 4090)
System Power Input @ Heating (W)3189 (490 ~ 3710)
MCA: Min. circuit amps (A)
MOCP: Max. over current protection (A)
RLA: Rated load amps (A)
W: Fan motor rated output (W)

Piping

Throttle type (Indoor)EXV
Throttle type (Outdoor)EXV
Liquid Size9.52mm (3/8in)
Gas Size19mm (3/4in)
Max. Piping Length (ft/m)246 (75)
Max. Height Difference (ft/m)98.40 (30)
Max. Pre-charged Length (ft/m)24.6 (7.5)
Refrigerant Pre-charged Amount (oz/kg)116.40 (3.3)
Additional Charge of Refrigerant ((oz/ft)/(g/m))0.7 (65)
Connection MethodFlared

Indoor Unit Dimensions

Dimensions for 30K/36K models:

Dimension LabelDimension (inch)Dimension (mm)
A - Model Height491017
B - Model Width21559
C - Supply Air Opening Width18.8478.6
D - Return Air Opening Width21.2537.8
E - Model Depth21483
F - Supply Air Opening Depth9.3235.4
G - Return Air Opening Depth13.1332.5
H - Supply Air Opening Clearance1.641
I - Return Air Opening Side Clearance0.4210.6
J - Return Air Opening Front Clearance0.6316

Outdoor Unit Dimensions

Key dimensions for the outdoor unit (refer to diagrams for specific views and labels):

  • Width (W): 37.24 in (946 mm)
  • Depth (D): 16.14 in (410 mm)
  • Height (H): 31.89 in (810 mm)
  • Package Width: 42.91 in (1090 mm)
  • Package Depth: 19.69 in (500 mm)
  • Package Height: 34.84 in (885 mm)

Installation Instructions for Outdoor Unit

Clearance Requirements:

  • 20 inches (500mm) or more on sides, front, and rear when any 2 sides are clear.
  • 20 inches (500mm) or more when front and sides are clear.
  • 4 inches (100mm) or more on all sides.
  • 14 inches (350mm) or more on the front.

The unit meets all spatial requirements shown in Installation Clearance Requirements.

Fan Performance for Indoor Unit (30K)

This section presents a chart illustrating the relationship between external static pressure (in.w.c.) and air flow rate (CFM) for the 30K indoor unit. The chart displays distinct lines for different fan speeds: Turbo, H (High), M (Medium), and L (Low).

Model: SOV36H2BA / SWV36BDA (36K)

Series: SLIM4 Heat Pump Series

Indoor Specifications

ESP (inWG)0~0.8
Indoor Air Flow (Turbo/H/M/L/Si) (CFM)1189.0 / 1083.0 / 971.2 / 865.2 / /
Indoor Noise Level (Turbo/H/M/L/Si) (dBA)50.5 / 48 / 36.5 / N/A
Dimension (W×D×H)22.01 x 19.02 x 40.04 in (559 x 483 x 1017 mm)
Package (W×D×H)24.61 x 22.83 x 46.97 in (625 x 580 x 1193 mm)
Net/Gross Weight109.57 / 130.73 lbs (49.7 / 59.3 kg)

Outdoor Specifications

Compressor TypeROTARY
Compressor ModelKTF310D43UMT
RefrigerantR454B
Refrigerant Oil Charge (mL)1000
Refrigerant OilVG74
Outdoor Air Flow (Max) (CFM)2413.3
Outdoor Noise Level (dBA)62
Dimension (W×D×H)37.24 x 16.14 x 31.89 in (946 x 410 x 810 mm)
Package (W×D×H)42.91 x 19.69 x 34.84 in (1090 x 500 x 885 mm)
Net/Gross Weight153.22 / 163.58 lbs (69.5 / 74.2 kg)

Efficiency

CoolingHeating
SEER216.7HSPF2-4: 9.3
EER210.2COP: 3.3

Performance of Cooling

Rated Capacity (Btu/hr)36000
Min/Max Capacity (Btu/hr)11800~39000
Moisture Removal (L/h)3.37
Standard Operating Range (°F/°C)-25~50 (-25~50)
Rated Cooling ConditionsIndoor: 80°F DB/67°F WB, Outdoor: 95°F DB/75°F WB

Performance of Heating

1. @ 47°F Rated (Btu/hr)37000
2. @ 47°F Min/Max Capacity (Btu/hr)6900~41000
3. @ 17°F Rated (Btu/hr)24800
4. @ 5°F Rated: Capacity / COP29200 / 1.99
5. @ 5°F Max: Capacity (Btu/hr)29200
Standard Operating Range (°F/°C)-25~24 (-25~24)
Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 47°F DB/43°F WB
2. Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 17°F DB/15°F WB
3. Heating Conditions, Compressor Operating at Max. FrequencyIndoor: 70°F DB/60°F WB, Outdoor: 5°F DB/5°F WB

Electrical

Indoor Power Supply115/208/230V, 60Hz, 1Ph
Indoor MCA (115V/(208/230V))6.5A
Indoor MOP15A
Outdoor Power Supply208/230V, 60Hz, 1Ph
Outdoor MCA24A
Outdoor MOP30A
Communication WiringAWG 20-2
Compressor RLA17.5A
Outdoor Fan Motor RLA1.5A
Outdoor Fan Motor W/
Indoor Fan Motor RLA5A
Indoor Fan Motor W375W
System Power Input @ Cooling (W)3529 (760 ~ 4090)
System Power Input @ Heating (W)3189 (490 ~ 3710)
MCA: Min. circuit amps (A)
MOCP: Max. over current protection (A)
RLA: Rated load amps (A)
W: Fan motor rated output (W)

Piping

Throttle type (Indoor)EXV
Throttle type (Outdoor)EXV
Liquid Size9.52mm (3/8in)
Gas Size19mm (3/4in)
Max. Piping Length (ft/m)246 (75)
Max. Height Difference (ft/m)98.40 (30)
Max. Pre-charged Length (ft/m)24.6 (7.5)
Refrigerant Pre-charged Amount (oz/kg)116.40 (3.3)
Additional Charge of Refrigerant ((oz/ft)/(g/m))0.7 (65)
Connection MethodFlared

Indoor Unit Dimensions

Dimensions for 30K/36K models:

Dimension LabelDimension (inch)Dimension (mm)
A - Model Height491017
B - Model Width21559
C - Supply Air Opening Width18.8478.6
D - Return Air Opening Width21.2537.8
E - Model Depth21483
F - Supply Air Opening Depth9.3235.4
G - Return Air Opening Depth13.1332.5
H - Supply Air Opening Clearance1.641
I - Return Air Opening Side Clearance0.4210.6
J - Return Air Opening Front Clearance0.6316

Outdoor Unit Dimensions

Key dimensions for the outdoor unit (refer to diagrams for specific views and labels):

  • Width (W): 37.24 in (946 mm)
  • Depth (D): 16.14 in (410 mm)
  • Height (H): 31.89 in (810 mm)
  • Package Width: 42.91 in (1090 mm)
  • Package Depth: 19.69 in (500 mm)
  • Package Height: 34.84 in (885 mm)

Installation Instructions for Outdoor Unit

Clearance Requirements:

  • 20 inches (500mm) or more on sides, front, and rear when any 2 sides are clear.
  • 20 inches (500mm) or more when front and sides are clear.
  • 4 inches (100mm) or more on all sides.
  • 14 inches (350mm) or more on the front.

The unit meets all spatial requirements shown in Installation Clearance Requirements.

Fan Performance for Indoor Unit (30K)

This section presents a chart illustrating the relationship between external static pressure (in.w.c.) and air flow rate (CFM) for the 30K indoor unit. The chart displays distinct lines for different fan speeds: Turbo, H (High), M (Medium), and L (Low).

Model: SOV36H2BA / SWV36BDA (36K)

Series: SLIM4 Heat Pump Series

Indoor Specifications

ESP (inWG)0~0.8
Indoor Air Flow (Turbo/H/M/L/Si) (CFM)1189.0 / 1083.0 / 971.2 / 865.2 / /
Indoor Noise Level (Turbo/H/M/L/Si) (dBA)50.5 / 48 / 36.5 / N/A
Dimension (W×D×H)22.01 x 19.02 x 40.04 in (559 x 483 x 1017 mm)
Package (W×D×H)24.61 x 22.83 x 46.97 in (625 x 580 x 1193 mm)
Net/Gross Weight109.57 / 130.73 lbs (49.7 / 59.3 kg)

Outdoor Specifications

Compressor TypeROTARY
Compressor ModelKTF310D43UMT
RefrigerantR454B
Refrigerant Oil Charge (mL)1000
Refrigerant OilVG74
Outdoor Air Flow (Max) (CFM)2413.3
Outdoor Noise Level (dBA)62
Dimension (W×D×H)37.24 x 16.14 x 31.89 in (946 x 410 x 810 mm)
Package (W×D×H)42.91 x 19.69 x 34.84 in (1090 x 500 x 885 mm)
Net/Gross Weight153.22 / 163.58 lbs (69.5 / 74.2 kg)

Efficiency

CoolingHeating
SEER216.7HSPF2-4: 9.3
EER210.2COP: 3.3

Performance of Cooling

Rated Capacity (Btu/hr)36000
Min/Max Capacity (Btu/hr)11800~39000
Moisture Removal (L/h)3.37
Standard Operating Range (°F/°C)-25~50 (-25~50)
Rated Cooling ConditionsIndoor: 80°F DB/67°F WB, Outdoor: 95°F DB/75°F WB

Performance of Heating

1. @ 47°F Rated (Btu/hr)37000
2. @ 47°F Min/Max Capacity (Btu/hr)6900~41000
3. @ 17°F Rated (Btu/hr)24800
4. @ 5°F Rated: Capacity / COP29200 / 1.99
5. @ 5°F Max: Capacity (Btu/hr)29200
Standard Operating Range (°F/°C)-25~24 (-25~24)
Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 47°F DB/43°F WB
2. Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 17°F DB/15°F WB
3. Heating Conditions, Compressor Operating at Max. FrequencyIndoor: 70°F DB/60°F WB, Outdoor: 5°F DB/5°F WB

Electrical

Indoor Power Supply115/208/230V, 60Hz, 1Ph
Indoor MCA (115V/(208/230V))6.5A
Indoor MOP15A
Outdoor Power Supply208/230V, 60Hz, 1Ph
Outdoor MCA24A
Outdoor MOP30A
Communication WiringAWG 20-2
Compressor RLA17.5A
Outdoor Fan Motor RLA1.5A
Outdoor Fan Motor W/
Indoor Fan Motor RLA5A
Indoor Fan Motor W375W
System Power Input @ Cooling (W)3529 (760 ~ 4090)
System Power Input @ Heating (W)3189 (490 ~ 3710)
MCA: Min. circuit amps (A)
MOCP: Max. over current protection (A)
RLA: Rated load amps (A)
W: Fan motor rated output (W)

Piping

Throttle type (Indoor)EXV
Throttle type (Outdoor)EXV
Liquid Size9.52mm (3/8in)
Gas Size19mm (3/4in)
Max. Piping Length (ft/m)246 (75)
Max. Height Difference (ft/m)98.40 (30)
Max. Pre-charged Length (ft/m)24.6 (7.5)
Refrigerant Pre-charged Amount (oz/kg)116.40 (3.3)
Additional Charge of Refrigerant ((oz/ft)/(g/m))0.7 (65)
Connection MethodFlared

Indoor Unit Dimensions

Dimensions for 30K/36K models:

Dimension LabelDimension (inch)Dimension (mm)
A - Model Height491017
B - Model Width21559
C - Supply Air Opening Width18.8478.6
D - Return Air Opening Width21.2537.8
E - Model Depth21483
F - Supply Air Opening Depth9.3235.4
G - Return Air Opening Depth13.1332.5
H - Supply Air Opening Clearance1.641
I - Return Air Opening Side Clearance0.4210.6
J - Return Air Opening Front Clearance0.6316

Outdoor Unit Dimensions

Key dimensions for the outdoor unit (refer to diagrams for specific views and labels):

  • Width (W): 37.24 in (946 mm)
  • Depth (D): 16.14 in (410 mm)
  • Height (H): 31.89 in (810 mm)
  • Package Width: 42.91 in (1090 mm)
  • Package Depth: 19.69 in (500 mm)
  • Package Height: 34.84 in (885 mm)

Installation Instructions for Outdoor Unit

Clearance Requirements:

  • 20 inches (500mm) or more on sides, front, and rear when any 2 sides are clear.
  • 20 inches (500mm) or more when front and sides are clear.
  • 4 inches (100mm) or more on all sides.
  • 14 inches (350mm) or more on the front.

The unit meets all spatial requirements shown in Installation Clearance Requirements.

Fan Performance for Indoor Unit (30K)

This section presents a chart illustrating the relationship between external static pressure (in.w.c.) and air flow rate (CFM) for the 30K indoor unit. The chart displays distinct lines for different fan speeds: Turbo, H (High), M (Medium), and L (Low).

Model: SOV36H2BA / SWV36BDA (36K)

Series: SLIM4 Heat Pump Series

Indoor Specifications

ESP (inWG)0~0.8
Indoor Air Flow (Turbo/H/M/L/Si) (CFM)1189.0 / 1083.0 / 971.2 / 865.2 / /
Indoor Noise Level (Turbo/H/M/L/Si) (dBA)50.5 / 48 / 36.5 / N/A
Dimension (W×D×H)22.01 x 19.02 x 40.04 in (559 x 483 x 1017 mm)
Package (W×D×H)24.61 x 22.83 x 46.97 in (625 x 580 x 1193 mm)
Net/Gross Weight109.57 / 130.73 lbs (49.7 / 59.3 kg)

Outdoor Specifications

Compressor TypeROTARY
Compressor ModelKTF310D43UMT
RefrigerantR454B
Refrigerant Oil Charge (mL)1000
Refrigerant OilVG74
Outdoor Air Flow (Max) (CFM)2413.3
Outdoor Noise Level (dBA)62
Dimension (W×D×H)37.24 x 16.14 x 31.89 in (946 x 410 x 810 mm)
Package (W×D×H)42.91 x 19.69 x 34.84 in (1090 x 500 x 885 mm)
Net/Gross Weight153.22 / 163.58 lbs (69.5 / 74.2 kg)

Efficiency

CoolingHeating
SEER216.7HSPF2-4: 9.3
EER210.2COP: 3.3

Performance of Cooling

Rated Capacity (Btu/hr)36000
Min/Max Capacity (Btu/hr)11800~39000
Moisture Removal (L/h)3.37
Standard Operating Range (°F/°C)-25~50 (-25~50)
Rated Cooling ConditionsIndoor: 80°F DB/67°F WB, Outdoor: 95°F DB/75°F WB

Performance of Heating

1. @ 47°F Rated (Btu/hr)37000
2. @ 47°F Min/Max Capacity (Btu/hr)6900~41000
3. @ 17°F Rated (Btu/hr)24800
4. @ 5°F Rated: Capacity / COP29200 / 1.99
5. @ 5°F Max: Capacity (Btu/hr)29200
Standard Operating Range (°F/°C)-25~24 (-25~24)
Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 47°F DB/43°F WB
2. Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 17°F DB/15°F WB
3. Heating Conditions, Compressor Operating at Max. FrequencyIndoor: 70°F DB/60°F WB, Outdoor: 5°F DB/5°F WB

Electrical

Indoor Power Supply115/208/230V, 60Hz, 1Ph
Indoor MCA (115V/(208/230V))6.5A
Indoor MOP15A
Outdoor Power Supply208/230V, 60Hz, 1Ph
Outdoor MCA24A
Outdoor MOP30A
Communication WiringAWG 20-2
Compressor RLA17.5A
Outdoor Fan Motor RLA1.5A
Outdoor Fan Motor W/
Indoor Fan Motor RLA5A
Indoor Fan Motor W375W
System Power Input @ Cooling (W)3529 (760 ~ 4090)
System Power Input @ Heating (W)3189 (490 ~ 3710)
MCA: Min. circuit amps (A)
MOCP: Max. over current protection (A)
RLA: Rated load amps (A)
W: Fan motor rated output (W)

Piping

Throttle type (Indoor)EXV
Throttle type (Outdoor)EXV
Liquid Size9.52mm (3/8in)
Gas Size19mm (3/4in)
Max. Piping Length (ft/m)246 (75)
Max. Height Difference (ft/m)98.40 (30)
Max. Pre-charged Length (ft/m)24.6 (7.5)
Refrigerant Pre-charged Amount (oz/kg)116.40 (3.3)
Additional Charge of Refrigerant ((oz/ft)/(g/m))0.7 (65)
Connection MethodFlared

Indoor Unit Dimensions

Dimensions for 30K/36K models:

Dimension LabelDimension (inch)Dimension (mm)
A - Model Height491017
B - Model Width21559
C - Supply Air Opening Width18.8478.6
D - Return Air Opening Width21.2537.8
E - Model Depth21483
F - Supply Air Opening Depth9.3235.4
G - Return Air Opening Depth13.1332.5
H - Supply Air Opening Clearance1.641
I - Return Air Opening Side Clearance0.4210.6
J - Return Air Opening Front Clearance0.6316

Outdoor Unit Dimensions

Key dimensions for the outdoor unit (refer to diagrams for specific views and labels):

  • Width (W): 37.24 in (946 mm)
  • Depth (D): 16.14 in (410 mm)
  • Height (H): 31.89 in (810 mm)
  • Package Width: 42.91 in (1090 mm)
  • Package Depth: 19.69 in (500 mm)
  • Package Height: 34.84 in (885 mm)

Installation Instructions for Outdoor Unit

Clearance Requirements:

  • 20 inches (500mm) or more on sides, front, and rear when any 2 sides are clear.
  • 20 inches (500mm) or more when front and sides are clear.
  • 4 inches (100mm) or more on all sides.
  • 14 inches (350mm) or more on the front.

The unit meets all spatial requirements shown in Installation Clearance Requirements.

Fan Performance for Indoor Unit (36K)

This section presents a chart illustrating the relationship between external static pressure (in.w.c.) and air flow rate (CFM) for the 36K indoor unit. The chart displays distinct lines for different fan speeds: Turbo, H (High), M (Medium), and L (Low).

PDF preview unavailable. Download the PDF instead.

Innovair-R454B-SLIM4-Front-Return-Wall-Mount-Heat-Pump-Submittals Adobe PDF Library 24.4.19

Related Documents

Preview Innovair SLIM4 Heat Pump Series Submittal Data Sheet
This document provides detailed submittal data for the Innovair SLIM4 Heat Pump Series, covering specifications, performance metrics, dimensional information, and features for models ranging from 18,000 to 60,000 BTU/hr.
Preview Innovair SLIM4 SWV Series Indoor Unit User Manual
Comprehensive user manual for the Innovair SLIM4 SWV Series indoor air conditioning unit, covering safety precautions, operation, maintenance, and troubleshooting. Features include split system cooling and heat pump functionality with R454B refrigerant.
Preview Innovair SLIM4 Hyper Heat Pump Series Submittal Data Sheet
Comprehensive submittal data sheet for the Innovair SLIM4 Hyper Heat Pump Series, detailing specifications, performance metrics, electrical requirements, piping details, and dimensional data for models SHV18H2BA/SAV18BDA through SHV60H2BA/SAV60BDA. Includes cooling and heating performance at various conditions, indoor and outdoor unit specifications, and installation clearance guidelines.
Preview Innovair SLIM4 SAV Series Indoor Unit User Manual
Comprehensive user manual for the Innovair SLIM4 SAV Series indoor unit, detailing safety precautions, installation, operation, maintenance, and troubleshooting for split system cooling and heat pump applications.
Preview Innovair Split Horizontal-Vertical Duct Air Conditioner Owner's and Installation Manual
Comprehensive owner's and installation manual for Innovair Split Horizontal-Vertical Duct Air Conditioners. This guide provides essential safety precautions, operating instructions, maintenance tips, troubleshooting advice, and detailed installation procedures for Innovair air conditioning units.
Preview INNOVAIR DEV Series Heat Pump & Air Conditioner AHRI Certified Ratings
Comprehensive AHRI certified product ratings for INNOVAIR DEV Series split system heat pumps and air conditioners, detailing SEER, EER, HSPF, and model specifications for both 2017 and 2023 standards.
Preview INNOVAIR SHV and SOV Series Heat Pump Product Ratings and IRA Tax Credit Eligibility
This document provides detailed product ratings for INNOVAIR SHV and SOV Series Heat Pump systems, including cooling and heating capacities, SEER2, EER2, and HSPF2 ratings. It also notes potential eligibility for the U.S. federal tax credit.
Preview Innovair GAV Series Indoor Unit Installer's Guide - Safety, Installation, and Specifications
Comprehensive installer's guide for Innovair GAV Series indoor air handler units (GAV24B2A, GAV36B2A, GAV48B2A, GAV60B2A). Covers installation, safety precautions, electrical wiring, airflow performance, ductwork, refrigerant pipe connection, maintenance, and wiring diagrams for R454B refrigerant systems.