Instruction Manual for Horow models including: BG-329R Walk In Bathtubs, BG-329R, Walk In Bathtubs, In Bathtubs, Bathtubs
2 ago 2024 — Warning Symbol: This icon reminds the user of the important operating and maintenance instructions! When finished using, the power switch must be disconnected.10 pagine
Installation & Operation Manual For Walk-in Bathtubs Pleasereadthismanualcompletelyandcarefullybeforeusingbathtubs Instructionsforuseofwalk-inbathtubs CONTENTS I.Instructionsforuse----------------------------------------------------------------------2 II.Productillustrations-----------------------------------------------------------------3-5 III.Basicparametersandmainfunctions----------------------------------------------5 IV.PartsLayout-----------------------------------------------------------------------------6 V.Installationinstructions-------------------------------------------------------------6-7 VI.Howtousethebathtub--------------------------------------------------------------8-9 VII.Cleaningandmaintenance-------------------------------------------------------9-10 VIII.Failuresandtroubleshooting-----------------------------------------------------10 Thankyouforyourpurchasing. Ourelaboratelydesignedproductswillmakeyourlifeeasy,cosyandcomfortabletoourcompany's greatesthonor. Inordertoassembleanduseourproductscorrectly,pleasereadthismanualcarefullyandfollowit strictly. W ew i l lp ro v i d ey o uw i t hd e d i cate da n ds at i s fi e ds e r v i ce . 2 Instructionsforuseofwalk-inbathtubs I.Instructionsforuse Besuretoreadtheinstructionscarefullybeforeinstallationanduse! T h eb o d y 'sre s p o n s etowate rte m p e rat u rei sv e r ys e n s i t i v e ,d e p e n d i n go nt h ep e r s o n 'sa ge ,h ea l t h ,a n d h i sto r yo fd r u grea ct i o n s .I fy o ud o n ' tk n o wy o u rre ce pt i v i t ytoh otwate r,o ri fy o uex p e r i e n ceh ea d a c h e s , dizzinessornauseawhileusingbathtub,pleasejuststopbathingorlowerthehotwatertemperature immediately. Cautions: DangerSymbol:Thisiconalertstheusertothehazardousvoltageofproduct! WarningSymbol:Thisiconremindstheuseroftheimportantoperatingandmaintenance instructions!Whenfinishedusing,thepowerswitchmustbedisconnected. 1.1GFCI(GroundFaultCircuitInterrupter)mustbeinstalledinpowerinletandthegrounding mustbereliable! 1.2Topreventanelectricshock,theconnectionandreplacementofthepowercordmustbe carriedoutbyaprofessionalelectricianordealer,andmustnotbereplacedprivately; 1.3Topreventanelectricshock,allconnectionsmustbeproperlyinsulated; 1.4Usethisbathtubwithcautionsifyouhaveheartdisease,highbloodpressureorlowbloodpessure; 1.5DANGER:Alcohol,drugs,ormedicationsposesahazard;personstakingmedicationsor allergictomedicationsshouldconsultaphysicianbeforeusingthebathtub; 1.6Forthesafetyprotectionwhenbathtubinuse,importantsafetyinstructionsneedtobefollowed; 1.7Ensurethatallnozzlescanbesprayedoutsmoothly,donotartificiallyblockanywaterorairoutlets; 1.8Duetotherelativedeepwaterinthebathtub,itisabsolutelyforbiddenforchildrentousethis bathtubalone; 1.9Donotstartthemotorwhenthereisnowater,inordernottodamagethepump(Thisappliesonlyto bathtubswithmassagefunction); 3 Instructionsforuseofwalk-inbathtubs 1.10Ifthebathtubisusedfrequently,thepipesshouldbecleanedonceaweek(Thisappliesonlyto bathtubswithmassagefunction); 1.11Donotusethebathtubimmediatelyafterstrenuousexercise;ifyoufeelunwellduringorafter u s i n gt h ebat h t u b, j u ststo pu s i n gi ti m m e d i ate l ya n ds e ead o cto r ; 1 . 1 2Toa v o i du n n e ce s s a r ya cc i d e n ts ,p l ea s ed on otd r i n ka l co h o lw h i l eu s i n gm a s s a ge ; 1.13Prolongedimmersioninwatertemperaturesabove104°F(40°C)maybeharmfultothebody, 96.8°F-104°F(36°C-40°C)isthesafetemperaturerangeforthehumanbody,werecommendthatyou shouldmeasureaccuratelythetemperatureofthewaterbeforegettingintothebathtub,andwealso recommendthatthosewhohaveastrongreactiontohightemperaturesshouldbekeptatalower watertemperatureandstayinforashorterperiod; 1.14Excessivewatertemperaturescanbedetrimentaltopregnantwomen,anditisbestforpregnant womentousethewaterat100.4°F(38°C)andconsultaphysicianbeforeusingthebathtub; 1.15Allelectricalmaintenanceandrepairsmustbeperformedbyalicensedtechnician. 1.16MonthlytimedtestingofGFCI(GroundFaultCircuitInterrupter)shouldbecarriedout; 1.17Beforemaintenanceandrepairmustpoweroffaspernormaloperationmenu; 1 . 1 8Te sto n cep e ri n st r u ct i o n sa f te ra n ym a i n te n a n cea n dre pa i r ; 1.19Pleasecheckthebathtubaccessoriesaccordingtothecontentsofthepackinglist,andnotify thedealeratthefirsttimeofanymissingordamages. II.ProductExternalPicture 4 Instructionsforuseofwalk-inbathtubs 980mm/38 9/16" BG-329R 1250*660*980mm 493/16"*26"*38 9/16" 1250mm/49 3/16" III.Basicparametersandmainfunctions Watercapacity netweight grossweight(withcartonwoodenframe) grossweight(withhoneycombcarton) 260kg/573.2Ib 59.4kg/130.9Ib 86.4kg /190.4Ib 76kg /167.5Ib 3.2Mainfunctions Model KeyFeature BG-329 waterintakefunction Hotandcoldwater adjustmentfunction Handshowerfunction Manualdrainfunction 5 660mm/26" Instructionsforuseofwalk-inbathtubs IV.Partslayout · BG-329R Handrail Showerhead Drainwater Influentwaterfall Hotwaterswitch Temperatureregulator Drainswitch Coldwaterswitch Doorlock Glassdoor V.Installationinstructions I n sta l l at i o nT i p s :I ti sre co m m e n d e dt h aty o us h o u l dre s e r v et h ep l u m b i n gl o cat i o na cco rd i n gto thefollowingdiagrambeforeinstallation;theinstallationshouldbeinstalledbyaprofessional. Wheninstalling,pleasebecarefulofhandlingsoasnottobumporscratchthesurfaceoftheproduct. 5.1Plumbingandelectricalinstallationillustrations · BG-329R hotwaterintake16A 700 500 150 hotwaterintake Coldwaterintake 600 300-400 60 975 345 5.2Installationofbathtub 5.2.1Removethepackingbox,liftoutthebathtubandmoveittothedesiredplace;Ifthefloorisnot level,adjustthebottomgroundscrews,levelandtighten; 6 Instructionsforuseofwalk-inbathtubs 5.2.2Placethebathtubnearthelocationtobeinstalledandconnectthehotandcoldwaterpipes separatelytothecoldandhotwatersource(ofwhichblueforcoldwaterandredforhotwater),water pressureshouldbemorethan3kilograms,hotandcoldwaterpressureshouldbeataverage,;ifwater pressureisinsufficient,theownershouldinstallaboosterpumpatwateroutletofwatertoweronroof. water heaters Switch(turnonwheninuse) tobathtubhot waterhose tobathtubcold waterpipe T-joint touser'swater source 5 . 2 . 3S c re wt h ed ra i np i p etot h ed ra i na n di n s e r tt h ed ra i np i p ei n tot h ere s e r v e dh o l ei nt h efl o o r,t h e diameterofthedrainholeneedstobegreaterthanorequalto60mm(refertothewaterandelectricity installationdrawing); 5.2.4Connecttheshowerheadtotheshowerhose; 5.2.5TurnthefunctionswitchtoOFF; 5.2.6Installthewaterinlettothebathtubsurfaceandconnectthehightemperaturetubebetweenthe functionswitchandthewaterinlet; 5.2.7Afterthehotandcoldwaterisconnectedseparately,turnthefunctionswitchtocheckwaterleakage outoftheconnectedpipes; 5.2.8Fitthe100-mmhighsnapbarontotheshellandtightenwithanAllenkey. 5.2.9Afterinstalled,aspaceofmorethan500mmshallbeleftaroundthebathtubforfuturemaintenance andadjustment. 7 Instructionsforuseofwalk-inbathtubs VI.Howtousethebathtub 6.1Turnonthegeneralpowersupplyandturnonhotandcoldwater. 6 . 2P ro ce d u reo fo p e n i n ga n dc l o s i n gt h es i d ed o o r : 6 . 2 . 1O p e n i n gt h ed o o r :H o l dt h eb o l tw i t hy o u rh a n da n dl i f ti tu p wa rd s ,t h e np u s ht h ed o o ri n wa rd s togainaccess(asshowninthediagram). 6 . 2 . 2C l o s i n gt h ed o o r :T h este p sa n dd i re ct i o no fc l o s i n gt h ed o o ra ret h eo p p o s i teo fo p e n i n gt h e d o o r ;fi r st l yc l o s et h ed o o r,t h e np re s st h eb o l td o w n wa rd . 6.3Notesonboltuse: 6.3.1Donotapplyexcessivepressure(lessthan50Kgf )tothebolt .Donotuseitasahandrail,which maycausebreakdowntothelimitstructureoftheboltandsoresultsinboltdamages; 6.3.2Openthedoorwhenthebathtubisnotinuse; 8 Instructionsforuseofwalk-inbathtubs 6.4Whenthewaterlevelishigherthan20-30mmabovethepositionofthehighestnozzle,turnthe functionswitchtoOFFandstopfillinginmassage;pressthemassagepneumaticbuttontostart massagepumpformassage.Andcanstopmassagebypressingthebuttonagain.Prohibitturningon thepumpwhenwaterlevelisbelowthehighestnozzle,otherwisethewaterwillsprayouttothe outsideofthebathtubbecauseofhighwaterpressure(thisappliesonlytothebathtubwithmassage function); 6.5Turnthehydroswitchtoadjusttoadjustmassageintensity(thisonlyappliestobathtubswith massagefunction); 6.6Directlypressairswitchbuttontostartairpumptowork,andthenpressagaintostop.Theperiod tokeepairpumpinuseisfrom15to30minutes,thelongestperiodiswithin120minutes(this ppliesonlytothebathtubwithbubblebathfunction); 6 . 7Tu r nt h ef u n ct i o ns w i tc htos h o w e ra n dta ket h eh a n d - h e l ds h o w e rfo rs h o w e r ; 6.8Whenfinishedbathing,turnoffthemotorandturnclockwisethedraincontrolwheelfordraining. 6 . 9P re s s i n gt h eOzo n es w i tc hd i re ct l ytosta r tt h eo zo n ege n e rato r ;p re s s i n ga ga i ntosto pw o r k i n g . Thesanitizingfunctioncannotbeusedwhentakingabath(thisappliesonlytobathtubswithozone sanitizingfunction); 6.10Inthelastcleanoutthebathtubandturnoffthepower. VII.Cleaningandmaintenance 7.1Thebathtubcanbecleaneddailywithconventionalliquiddetergentandsoftcloth,butnot withdetergentcontainingacetoneorammonia; 7.2Ifthesurfaceofbathtubisscratchedorscuffed,justuse1500#watersandpaperwithwaterto grindawaythescars,thenapplytoothpasteandpolishwithasoftclothtillasbrightandcleanas new; 7.3Limescaleonthesurfaceofthebathtubcanberemovedwithaweakacidicwashing-upliquidand sassafrascleanerwithasoftcloth; 9 Instructionsforuseofwalk-inbathtubs 7.4Thereturnwaterelbowcanbecleanedbyunscrewingtheelbowoffifthereishairordebrisinit; 7.5Afteruse,drainthebathtubcompletelyanddisconnectthepowersupply; 7.6Donothitonthesurfaceofthebathtubwithhardobjects,andalsodonotallowcigarettebuttsor heatsourcesabove212°F(100°C)totouchthesurface; 7.7Hydro-massageunitcleaning:Fillinthetubwith104°F(40°C)hotwater(approximately320L)and putincleaneratadoseof2gramsperliter.Starthydro-massagetoworkfor5minutes,stopthepump anddraincompletely,thenfillinwithcoldwaterandstarthydro-massagetoworkforabout2 minutes,stopthepumpanddraincompletely.(thisonlyappliestobathtubswithmassagefunction); Eight,commonfaultsandtroubleshootingmethods Bathtubsurfacenotlevel Supportfeetnotadjusted Leakingofwaterpipes connections Badseals Nutnotlockedproperly Poorbondingattheinterface Adjustablesupportfeet Reinstallationorreplacement locknut Re -g l u i n g P.S.Thismanualisprovidedforreferenceonly.Theactualproductmaydifferfromthedescriptions herein,andchangesmaybemadewithoutpriornotification. 10Corel PDF Engine Version 24.0.0.301